Base Sensor Test
Use the Base sensor test to verify that the sensors located inside the printer are working correctly.
The following sensors can be checked using this test:
•
Input
•
Exit
•
Narrow Media
•
Front Door
CAUTION—SHOCK HAZARD: The sensor may be electrically energized. To avoid the risk of injury use a non-
conductive implement to toggle the sensors.
To run the Base sensor test:
1
From the Diagnostics menu, navigate to Base Sensor Test.
2
Choose a sensor.
3
Manually actuate the sensor to verify that it toggles. If the sensor does not toggle, then it is malfunctioning.
4
Press X to exit the test.
Device Tests
Flash Test
This test verifies the condition of the flash device by writing data to it and then reading data from it.
Warning—Potential Damage: This test deletes all data on the flash device.
1
From the Diagnostics menu, navigate to:
DEVICE TESTS > Flash Test
2
Files will be lost. Go/Stop? appears.
3
Do any of the following:
•
Press OK to continue.
•
Press X to cancel.
4
When the test starts, Flash Test Testing... appears. The test cannot be stopped or canceled after it has
begun.
5
After the test is complete, a message appears indicating a pass or fail result.
Sensor
Values
Input
Open
Exit
Closed
Front Door
Narrow Media
Narrow
Wide
Service menus