Problem
One or more of the fixtures is
completely dead.
Fixtures reset correctly but all
respond erratically or not at
all to the controller.
Fixtures reset correctly but
some respond erratically or
not at all to the controller.
Magnetically indexed effect
resets correctly but wanders
after fixture reaches operat-
ing temperature.
No light and "LERR" error
message displayed.
Lamp cuts out intermittently.
29
Probable cause(s)
No power to fixture.
Primary fuse blown.
Secondary fuse(s) blown.
Filter/power protection fuse blown.
The controller is disconnected from the
data link.
XLR pin-out of the controller does not
match pin-out of the first fixture on the link
(i.e. signal is reversed).
Bad data link connection
Data link not terminated with 120 Ω
termination plug.
Incorrect addressing of the fixtures.
One of the fixtures is defective and dis-
turbs data transmission on the link.
XLR pin-out on fixtures does not match
(pins 2 and 3 reversed).
Effect wheel or magnetic sensor requires
mechanical adjustment.
The ballast and transformer settings do
not match local AC voltage and frequency.
Lamp blown
Lamp not installed
Fixture is too hot.
The ballast and transformer settings do
not match local AC voltage and frequency.
RoboScan Pro 918
Remedy
Check that power is on and cables are plugged
in.
See "Changing voltage and frequency settings"
on page 18.
Connect controller.
Install a phase-reversing cable between the
controller and the first fixture on the link.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged
cables.
Insert termination plug in output jack of the last
fixture on the link.
Check fixture address and protocol settings.
Bypass one fixture at a time until normal oper-
ation is regained. Do this by unplugging the
XLR in and out connectors and connecting
them directly together. Have the fixture ser-
viced by a qualified technician.
Install a phase-reversing cable between the fix-
tures or swap pins 2 and 3 in the fixture that
behaves erratically.
Disable effects feedback (page 10). Contact
Martin technician for assistance.
Disconnect fixture. Check ballast and trans-
former settings and correct if necessary.
Disconnect fixture and replace lamp.
Disconnect fixture and install lamp.
Allow fixture to cool.
Reduce ambient room temperature.
Recalibrate temperature sensors.
Disconnect fixture. Check ballast and trans-
former settings and correct if necessary.