Manual Control; Stand-Alone Sequences; Utilities - Martin RoboScan Pro 918 User Manual

Table of Contents

Advertisement

M
A N U A L C O N T R O L
M a n u a l c o n t r o l (
The manual control menu permits you to do the following without a controller:
reset the fixture (
turn the lamp on and off (
open, close, and strobe the shutter at 3 speeds (
control the dimmer (
move the color wheels to each position and scroll them at 3 speeds (
move the fixed-gobo wheel to each position (
move the rotating-gobo wheel to each position and rotate the gobos at 3 speeds (
control the focus (
control the iris (
insert and rotate the prism (
control pan and tilt (
A d j u s t m e n t (
The adjustment menu provides manual control for making mechanical adjustments. These should be performed by a
qualified technician. The menu allows you to reset the fixture (
trol all effects (FX), and move the mirror to the home and extreme positions (
to:
open, close, and strobe the dimmer/shutter (
move the color and gobo wheels through their positions (
move the focus lens to its extreme positions (
open and close the iris (
insert and rotate the prism (
S
-
T A N D
A L O N E S E Q U E N C E S
D e m o n s t r a t i o n p r o g r a m s (
This menu offers 2 preprogrammed demonstrations. Demo 1 shows each effect individually and in combination with
others. Pan and tilt are static. Demo 2 pans and tilts within a defined area and shows various effect combinations.
Before running demo 1, set the pan/tilt position (
focus (
F OCU
define an area such as a screen or wall by setting the minimum and maximum pan and tilt positions (
MIN T
MA XT
,
Te s t s e q u e n c e s
Test sequence (
Printed circuit board test (
T2
,
T3
, and
Factory test (
S TST
test (
wheels (
C OL1
U
T I L I T I E S
C a l i b r a t i o n (
The calibration menu allows you to adjust the effects to achieve total uniformity between fixtures: it is not a substitute
for mechanical adjustment. Select dimmer/shutter (
(
RGO F
), focus (
adjustable from 1 to 255 for all effects except the fixed-gobo wheel, which is adjustable from 127 to 129. Press
>ENTER@ýto save the calibration.
)
MAN
RST
)
L ON
,
Lo FF
dIM
)
FOC U
)
I RIS
)
P RIS
) at 3 speeds, or, if a frost filter is installed, vary the frost (
P AN
TIL T
,
)
)
A dJ
IR IS
)
P RIS
)
) the beam. Select
SEQ
to run the demo. Demo 2 is similar but instead of defining a home position, you
). Focus the beam in the center of the area.
T SEQ
): Run a general test of all effects.
SPE C
/
PCB T
LEd
.
SP EC
/
FT ST
): This menu provides an effects test (
) used for quality control. The sensor test includes programs for testing sensors on the color and gobo
,
CO L2
,
Rgo b
, and
F gob
)
CAL
FOO F
), or fixed-gobo wheel (
)
SH UT
)
COL 1
Fgob
)
RST
), turn on and off the lamp (
d IM
)
C OL1
,
CO L2
F OCU
)
)
dE MO
PA N
,
TI LT
) to a good location for viewing the effects and then
): This menu provides 4 tests of the circuit board for service use:
ET ST
).
d O F
), color wheels (
F GOF
) and adjust the effect's offset with the arrow keys. Offsets are
Control Panel
,
C OL2
)
Rg ob
)
FR OS
)
L ON
PA TI
). The
FX
submenu allows you
,
Fgo b
,
R gob
)
), a movement test (
M TST
C 1OF
,
C2 OF
), rotating-gobo wheel
LoFF
,
), con-
MIN P
,
M AXP
,
TI
,
), and a sensor
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents