Changing Voltage And Frequency Settings - Martin RoboScan Pro 918 User Manual

Table of Contents

Advertisement

C
H A N G I N G V O L T A G E A N D F R E Q U E N C Y S E T T I N G S
Operating at the wrong setting can result in poor output, greatly reduced lamp life, overheating and fixture damage.
E U v e r s i o n
Local AC Supply
Frequency
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 HZ
60 HZ
1. Make sure the fixture is isolated from AC power. Access the transformer and ballast as described above.
2. On the transformer (F), move the BROWN wire to the terminal listed for your voltage. The terminal numbers
are printed in front of the connection tabs.
3. On the ballast (E), move the BROWN wire to the terminal listed for your voltage and frequency.
4. Replace the cover.
U S v e r s i o n
Fixtures wired for 100 or 120 volt operation shall have a 10 ampere main fuse
(P/N 05020025). Replace this with a 6.3 ampere fuse (P/N 05020020) if rewiring
Local AC Supply
Frequency
60 Hz
50 HZ
1. Make sure the RoboScan Pro 918 is isolated from AC power. Access the trans-
former and ballast as described above.
2. Find the correct transformer setting for your AC supply in the table above. The
colors refer to the wires that enter the connection block at the bottom. The figure
to right shows the transformer connection block as seen from the top. On the
transformer (F), move the BROWN wire to the correct terminal.
3. On the ballast (E), move the BROWN wire to terminal 7 (60 Hz), or terminal 10
(50 Hz). The other terminals are not used because the ballast is fed 230 volts
from the transformer.
4. Replace the cover.
Voltage
Setting
200-210 V
210 V
210-220 V
220-235 V
230 V
235-240 V
240-260 V
250 V
200-217 V
210 V
217-240 V
230 V
I M P O R T A N T !
for 230 or 250 volt operation.
Voltage
Setting
98 - 105 V
100 V
118 - 126 V
120 V
220 - 240 V
230 V
240 - 260 V
250 V
99 - 105 V
100 V
118 - 126 V
120 V
220 - 240 V
230 V
240 - 260 V
250 V
Basic Service and Maintenance
Transformer
Terminal
4
6
8
4
6
Transformer
Terminal
red
orange
yellow
green
red
orange
yellow
green
Magnetic Ballast
Setting
Terminal
200 V / 50 Hz
7
230 V / 50 Hz
10
245 V / 50 Hz
12
208 V / 60 Hz
4
227 V / 60 Hz
7
Ballast
Setting
Terminal
227 V / 60 Hz
227 V / 60 Hz
7
227 V / 60 Hz
227 V / 60 Hz
230 V / 50 Hz
230 V / 50 Hz
10
230 V / 50 Hz
230 V / 50 Hz
250 V
230 V
120 V
100 V
US version transformer
connections
18