Electrical specifications

Standard electrical – 115V, 60 Hz, 1 phase
110 series manual load – C110 – 2.0 amps, max. fuse size 15 amps
110 series automatic load – requires separate circuit and disconnect for icemaker and dispenser
(exc. F1105A/W)
C110R5A/W, C110T5A/W –
F1105A/W – 13.0 amps, max. fuse size 20 amps
Alternate electrical configurations (for non-domestic use) – 230V, 50 Hz, 1 phase
110 series manual load – Max. fuse size 15 amps
C110 –.8 amps
110 series automatic load – requires separate circuit and disconnect for icemaker and dispenser (exc. F1105A/W)
C110R5A/W, C110T5A/W – Icemaker 6.0 amps, dispenser .8 amps, max. fuse size 15 amps
F1105A/W – 6.8 amps
Model C110 is equipped with cord and plug. All other models to be hard wired. Equipment ground required. Electric
disconnect required within 10 ft (3m) of dispenser.

Plumbing specifications

Countertop 110 series
Dispenser
Icemaker
Freestanding 110 series (Models F1105A/W)
Dispenser
Icemaker
Note:
Water disconnect within 10 feet (3m) of dispenser suggested for automatic load units.
Drain should be hard piped, insulated and maintain min. 1/4" per foot (6mm per 304mm) slope.
How dispenser works
Follett's 110 series ice dispensers are available as either manual load models (using ice from another source) or
automatic load models fed from one or two Follett 400 lbs (181kg)/day icemakers. Depending on the model, the icemaker
may be located in the base of the dispenser, mounted on top or remoted to a location up to 20 feet (6m) from the
dispenser. In all models, ice is stored in the upper section of the dispenser. On lever and pushbutton dispensers, when
the dispenser lever or button is pushed, the ice dispense solenoid is energized. This opens the gate and activates the
dispense motor. This causes the wheel assembly in the storage area to turn, moving ice to the dispense chute where it
drops by gravity into the container.
In automatic load models, ice is made in the icemaker section which may be located in the base, top-mounted or remoted
from up to 20 ft away. As water freezes to the inside walls of the evaporator, a rotating stainless steel auger removes ice
and carries it to the top of the evaporator assembly where it is compressed and extruded through an outlet port. The ice is
then pushed through the tube to the storage compartment in the top of the dispenser. When the storage area is full, a bin
thermostat opens and shuts off the icemaker.
Automatic load units are equipped with a level fill circuit that maximizes fill in the storage area by rotating the wheel at
intervals until the bin is completely filled. When the bin is filled, a bin stat shuts off the icemaker to avoid overfilling of the
bin. The icemaker will restart after 20 minutes if the bin stat is calling for ice.
Icemaker 11.0 amps, max. fuse size 20 amps
Dispenser 2.0 amps, max. fuse size 15 amps
C110B – 1.2 amps
3/4" FPT dispenser drain
1/2" MPT icemaker drain
3/8" FPT water inlet
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
3/4" FPT dispenser drain
3/8" FPT water inlet
3/8" FPT icemaker drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)