Replacement of ice transport tube – Units with top-mounted icemakers
If preparing tubing not supplied by Follett, dispenser end of
!
tube must be fitted with mounting pins as shown in
drawing.
1. Slip a hose clamp on end of transport tube without pins, immerse this end
in cup of hot water to soften hose, then push it on evaporator port of
icemaker.
2. Fasten tube on evaporator port with hose clamp, being sure that clamp is
positioned on evaporator side of flange. Tighten clamp.
3. Insert loose end of ice tube into bracket on icemaker base as shown in
drawing.
4. Pull up on ice tube to seat pins in bracket.
Ice transport tube replacement – Freestanding units and units with remote icemakers
Correct installation of ice transport tube is critical to icemaker performance.
Replacement ice transport tubes must be insulated and must run continuously
!
from icemaker to dispenser with no dips in line and no bends with a radius of less
than 6" (153mm).
1. Remove top and rear access panel from dispenser (and lower front panel on freestanding unit).
2. Disconnect existing ice tube from engaging pin and pull down through dispenser chase.
3. Disconnect opposite end of tube from icemaker.
4. Run end of new ice transport tube with 3/16" (5mm) hole
through right hand knockout in back of dispenser or through
counter into bottom of dispenser, being careful to avoid any
bends with less than a 6" (153mm) radius.
5. Insert tube in internal chase in rear inside corner of dispenser
(right side as you face rear of dispenser) and push up into
storage area.
6. Push 3/16" (5mm) hole near end of tube into pin on ice tube
bracket (see drawing at right).
Steps 6 – 7 for units with remote icemakers only
7. Install supplied insulation to run of transport tube required for
your site, leaving approximately 2" (51mm) of tube exposed at free end.
8 Check that insulated tube runs continuously uphill to dispenser with no dips.
All units
9 Place free end of tube in a cup of hot water to soften, slip supplied hose clamp onto
tube and push tube onto exit port of evaporator. DO NOT TWIST HOSE WHEN
SECURING TO EVAPORATOR.
10. Fasten tube on port with hose clamp, being sure that clamp is positioned on evaporator
side of flange.
11. Tighten clamp.
capillary
tube
11
ice tube
mounting pin
plate
gasket
cap tube
bracket
ice
deflector
1"
(26mm)
ice tube
3/16"
bracket
(5mm)
ice
hole in
tube
ice tube
Section A–A
A
ice tube
bracket
icemaker
base
engaging pin
Back wall
3/16" (5mm)
dia. hole
1"
(26mm)
A

Advertisement

Table of Contents
loading

Table of Contents