Maintenance
item No.
Setting system 3
U612
Description
Makes settings for fax transmission regarding operation and automatic printing of the protocol list.
Start
1. Press the start key.
2. Select the item to be set. The screen for the selected item appears.
Display
AUTO REDUCTION
PROTOCOL LIST
The screen changes to the submenu for making settings.
The current settings are highlighted.
Selecting if auto reduction in the auxiliary direction is to be performed
Sets whether to receive a long document by automatically reducing it in the auxiliary direction or at 100%
magnification.
1. Select the setting.
Display
ON
OFF
2. Press the start key. The setting is set.

Setting the automatic printing of the protocol list

Sets if the protocol list is automatically printed out.
1. Select the setting.
Display
OFF
ERROR
ON
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the system 6
U615
Description
Makes settings for fax reception regarding the sizes of the fax paper and received images.
Purpose
To set the maximum recording width and processing method when 11" width fax paper is loaded on an inch
specification machine.
Method
1. Press the start key. The current setting is displayed in reverse.
2. Press [RX WIDTH FOR 11"].
3. Select the setting.
Display
LEDGER
B4
4. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Selects if auto reduction in the auxiliary direction is to be performed.
Sets the automatic printing of the protocol list.
Description
Auto reduction is performed if the received document is longer than the fax paper.
Auto reduction is not performed.
Description
The protocol list is not printed out automatically.
The protocol list is automatically printed out after communication only
if a communication error occurs.
The protocol list is automatically printed out after communication.
Description
Communicates to the destination unit 11" width as A3 width and
records at 100% magnifications.
Communicates to the destination unit 11" width as B4 width.
Description
3KH-2