Heatilator ICON I100 Installation & Operating Instructions Manual page 21

Woodburning fireplace
Table of Contents

Advertisement

ICON I100 INSTALLATION INSTRUCTIONS
16. Completion of the Enclosure
Complete the fireplace enclosure, allowing space for
outside air ducts and gas piping if desired. Electrical
wiring should not come in contact with the fireplace.
pages 9 and 10 for framing details.
Note:
Use only a noncombustible material to finish
the face of the fireplace below the level of the front
standoffs. A noncombustible material such as USG
MICORE CV230 Mineral Fiber Board, or USG
DUROCK Cement Board is recommended for this
purpose.
CAUTION:
17. Gas Log/Lighter Provisions
Knockouts are provided on both sides of the fireplace
to allow for connection of a certified gas log lighter or
a decorative gas appliance with a maximum input of
100,000 BTU/hour, incorporating an automatic gas
shutoff device and complying with the
appliance should be installed in accordance with the
refractories are designed to allow ½” iron pipe to pass
through. Use a noncombustible sealant to seal any
opening between the gas pipe and refractory on the
inside. Repack the insulation removed to seal around
the gas pipe where it exits the side of the fireplace. A
minimum 1½” air clearance must be provided around
the ½” iron pipe for a minimum of 4 inches beyond the
fireplace. See Figure 33.
WARNING!
12/03
See
. The decorative gas
. The side
35144 Rev E
Figure 33 - Air Clearance Around Gas Line
CLEARANCES!