Tells where hazards
may occur.
Electrical
Electrical
Electrical
Electrical
Electrical
Equipment
Equipment
Equipment
Equipment
Equipment
AH-94-04.7
H A Z A R D
H A Z A R D
H A Z A R D
H A Z A R D
H A Z A R D
Tells what the hazard is.
High voltage equipment is utilized.
Arcing in areas of flammable or
combustible materials may occur.
Personnel are exposed to high
voltage during operation and
maintenance.
Protection against inadvertent
arcing that may cause a fire or
explosion is lost if safety circuits
are disabled during operation.
Frequent power supply shutdown
indicates a problem in the system
which requires correction.
An electrical arc can ignite coating
materials and cause a fire or
explosion.
REA-90 and 90L Spray Applicators - Safety
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
Tells how to avoid the hazard.
The power supply, optional remote control cabinet,
and all other electrical equipment must be located
outside Class I or II, Division 1 and 2 hazardous
areas. (Exception: AVIATOR series applicators)
(Refer to NFPA-33.)
Turn the power supply OFF before working on the
equipment.
Test only in areas free of flammable or combus-
tible material.
Testing may require high voltage to be on, but only
as instructed.
Production should never be done with the safety
circuits disabled.
Before turning the high voltage on, make sure no
objects are within the sparking distance.