Ransburg 75785 Service Manual page 47

Electrostatic spray applicators
Hide thumbs Also See for 75785:
Table of Contents

Advertisement

2. Remove the gasket from the handle if it did not
come out with the barrel.
3. Slide the hook/transformer forward and out of
the handle channel.
T T T T T esting and Repair
esting and Repair
esting and Repair
esting and Repair
esting and Repair
N O T E
N O T E
N O T E
N O T E
N O T E
The hook/transformer can be tested
>
using the Transformer Output Tester and
following the guidelines of it's instruction
manual. If the transformer output tester is
not available, the following procedure can
be used to test the hook/transformer.
1. Prior to testing the hook/transformer, the
following test procedures must be conducted:
• Low Voltage Cable Test
• Low Voltage Cable Plug Assembly Test
Item #
Item #
Item #
Item #
Item #
Description
Description
Description
Description
Description
25
Hook/Transformer
78
Low Voltage Cable Plug
77
Low Voltage Cable
A
Low Voltage Controller
Figure 16: Hook/Transformer
Figure 16: Hook/Transformer
Figure 16: Hook/Transformer
Figure 16: Hook/Transformer
Figure 16: Hook/Transformer
Test Setup Diagram
Test Setup Diagram
Test Setup Diagram
Test Setup Diagram
Test Setup Diagram
AH-94-04.7
REA-90 and 90L Spray Applicators - Maintenance
2. Connect the low voltage cable to a control unit
and a cable plug assembly (refer to Figure 16).
3. Connect the low voltage cable and the plug
assembly to the hook/transformer. This can be
done without the handle on a workbench or with
the hook/transformer, low voltage cable, and plug
assembly installed into a handle. DO NOT perform
this test with the barrel attached to the hook/
transformer.
4. On the control unit, turn the high voltage
adjustment knob fully counter-clockwise.
5. Make sure that the on/off switch of the hook/
transformer is in the "ON" position, if the unit has
this option (refer to Figure 17).
6. Turn the control unit on and adjust the voltage
knob clockwise to increase the voltage to the
hook/transformer.
7. Watch the red lens at the rear of the hook/
transformer. As the voltage is increased, the LED
behind the lens will increase in intensity. Once the
voltage control knob is turned fully clockwise, the
LED should be at it's highest intensity.
Figure 17: Hook/Transformers
Figure 17: Hook/Transformers
Figure 17: Hook/Transformers
Figure 17: Hook/Transformers
Figure 17: Hook/Transformers
Switch Position
Switch Position
Switch Position
Switch Position
Switch Position
4 2
4 2
4 2
4 2
4 2