Section Five - Infinity 600 CF Owner's Manual

Table of Contents

Advertisement

600 CF
Users Instructions
SECTION FOUR
 Bridge Log Shapes 12 & 13
as shown.

SECTION FIVE

Gas Type:
Gas Pressure:
Pressure Test Point Location:
Gas Input:
Injectors:
Oxy pilot:
NOx Classification ................... 5
Gas Connection:
Data Badge Location:
Battery
Remote handset 3 x AAA 1.5 V,
Appliance 6 x 1.5V "C" Cell high power alkaline.
NOTE: The efficiency of this appliance has been measured as specified in BS 7977-1 2009 +A1:2013
and the result is 74.40% natural gas. The gross calorific value of the fuel has been used for this
efficiency calculation. Gastec have certified the test data from which it has been calculated. The
efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings.
When unpacking the appliance please check the following items are included:
Fuel Bed: Owners Manual, Trim
Fuel Bed Cleaning and Layout Continued
Appliance Data
NATURAL GAS
CATEGORY I 2 H
20 mbar +/- 1.0mbar
Gas inlet elbow
5.5 kW Gross (Max.)
2.4 kW Gross (Min.)
Mk 360
9102 N.G.
8mm compression: semi-rigid or rigid
Located on the left hand side of the base of the appliance behind
the trim.
12
PROPANE GAS
CATERGORY 1 3 P
37 mbar +/- 1.0mbar
5.0kW Gross (Max.)
2.4kW Gross (Max.)
Mk 116
9264 L.P.G.
LT5889 issue 7(10/12)

Advertisement

Table of Contents
loading

This manual is also suitable for:

890 cf

Table of Contents