Gate Overlap Setting - Viking G-5 Installation Instructions Manual

Vehicular gate operator
Table of Contents

Advertisement

SPECIAL FEATURES
SPECIAL FEATURES

Gate Overlap Setting

Setting the Overlap Delay Pot to "0" will cause the master and the slave units to
open and close at the same time
A Master/Slave control board is required to
operate two gates with a single controller.
UL
(Master/Slave Unit Board shown)
Siren
Setting the Overlap Delay Pot to any value
other than zero will cause the master unit to
delay in opening.
The time delay can be set for up to 3 seconds.
Mag. Lock
Master Unit
28
Trim Pot Location
Limit
Close
Stop
MAG
LOCK
Guard Station
Outside
Inside
Overlap Delay
Limit
Hold Open
Open
60sec
Open Commands
Opens First
TECHNICAL SUPPORT 1 800 908 0884
Obstruction
Sensor
1.5
3
0
Timer
30sec
1sec
off
Safety Connector
Slave Unit
Center
Loop
27