CONTROL BOX INSTALLATION

CONTROL BOX INSTALLATION
WARNING - If the control box is not
mounted properly it may fall, causing
damage and/or injury. The Electronic
Control Unit (ECU) weight is
approximately 40 lbs. Be sure that the
substrate being mounted to and the
fasteners being used are appropriate to
support the weight of the control box.
1. Disconnect the Siren and Stop Button
Leads from the Control Board. Remove
the Control Board Mounting Plate. The
plate is held in the box by four screws.
2. Position the ECU Box in the desired place
and mark the mounting holes. Prepare the
holes to receive the anchors/fasteners.
3. Position the ECU Box and secure it to the
mounting surface using the Sealed
Washers provided (place the rubber side
of the washers against the inside of the
control box).
Note: Depending on type of anchor used, it
may be necessary to enlarge the
mounting holes in the control box.
16
Mounting Fastener
(Customer Supplied)
Sealed Washer
(Supplied with Unit)
TECHNICAL SUPPORT 1 800 908 0884
15" Standard
17" Industrial
14" Standard
16" Industrial
Depth:
6.5" Standard
6.5" Industrial
Control Box
Mounting Surface