GATE OPERATOR INSTALLATION

Pull to Open Installation Option
This application is typically used to open the gate towards the inside of the
property. The operator will " PULL" the gate to open.
1.
The gate must be installed in a location so that enough clearance is provided
between the gate and adjacent structures to reduce the risk of entrapment
when opening and closing.
2. Swing gates are not to open into public access areas.
Range
A
90° - 120°
6.000
90° - 120°
6.625
121° - 135°
5.500
!
Varying from the dimensions provided above may severely af fect the speed and
performance of the gate operator.
1 4
www.PerformanceGateOpeners.com | (800) 878-7829 | Sales@PerformanceGateOpeners.com
ALL DIMENSIONS ARE MEASURED IN INCHES
B
C
4.500
27.000
7.875
28.000
9.000
27.000
NOTE:
Back Mounting Bracket
must be cut to obtain correct
dimension "A" provided below.
D
E
31.500
4.750
35.875
4.750
36.000
4.000
Opening Time
Faster
Slower