IMPORTANT SAFETY INFORMATION
IMPORTANT SAFETY INFORMATION
WARNING - Not following these instructions may cause severe injury or death to persons.

Audible Alarm Reset Switch Installation

Manual Reset for the Audible Alarm
UL325 standard requires an audible alarm to go off after two consecutive events
detected by the primary entrapment protection of the gate operator (obstruction sensor).
The audible alarm will continue to sound for 5 minutes or until a stop command
gets actuated.
The Stop command can be actuated in two different forms
1. Using the Built in Stop switch on the Control Box or
2. Using an External Stop button within the sight of the gate, away from moving
parts of the gate and out of reach of children.
3. Controls intended for user activation must be located at least six feet (6') away
from any moving part of the gate and where the user is prevented from reaching
over, under, around or through the gate to operate the controls. Outdoor or easily
accessible controls shall have a security feature to prevent unauthorized use.
4. The Stop and/or Reset button must be located in the line-of-sight of the gate.
Activation of the reset control shall not cause the operator to start.
Manual Stop

Warning Placard Installation

All Warning Signs and Placards must be installed where visible in the area
of the gate. A minimum of two placards shall be installed. A placard is
to be installed in the area of each side of the gate and be visible.
8
STOP
5'
Minimum
Button
Brake
Master/Slave
Master/Slave
UL
Siren
TECHNICAL SUPPORT 1 800 908 0884
Overlap Delay
Close
Stop
Open
Guard Station
Guard Station
Open Commands
Open Commands
N.O.
COM
S T O
Obstruction
Center
Sa
Sensor
Loop
min.
MAX
Hold Open
Timer
Safet
Loop
P
L