Fail Safe/Fail Secure Operation; Hold Open Timer - Viking G-5 Installation Instructions Manual

Vehicular gate operator
Table of Contents

Advertisement

SPECIAL FEATURES
SPECIAL FEATURES
Connection Locations
(Single Unit Board shown)
Minimum Force:
By removing the wire-jumper plug
from the "Fail Safe/Secure" connector:
The gate can be move manually with
relative low amount of force.
Maximum Force:
By inserting the wire-jumper plug into the
"Fail Safe/Secure" connector:
The gate can still be move by hand with
relative high amount of force.
Manual Operation Locked
By removing the "Break Release Pin" from
the operator:
The gate can't be moved manually.
Obstruction
Overlap Delay
Sensor
Caution: If the gate is moved manually,
damage may occur to the operator and/or
the gate system.
min.
Brake
Hold Open
Stop
Open
Master/Slave
Master/Slave
UL
Siren
Open Commands
Open Commands
Fail Safe/Fail Secure Operation
1
The gate operator contains a unique design that
allows the user to move the gate manually in case
of power failure.
There are three levels of force required to move
2
the gate manually.
Overlap Delay
Center
Safety
Loop
Loop
MAX
2
Close
Stop
Open
Timer
Guard Station
Guard Station
Safety Connector
Loop Connector
TECHNICAL SUPPORT 949-753-1279
TECHNICAL SUPPORT 1 800 908 0884
Fail
Safe/Secure
1
Obstruction
Center
Sensor
UL
Radio
Loop
Sensor
Rec.
min.
MAX
Hold Open Timer
Hold Open
Timer
The Hold Open Timer function holds the gate at
the open position for a predetermined amount
of time, prior to closing automatically.
Set the Timer to the desired time, from 1 to
60 seconds.
Open Commands
Open Commands
If this feature is not needed, turn the Trim
Pot clockwise to the "off" position.
Note: The Hold Open Timer affects the "radio
receiver command" and the sequence of
operation for the gate (see page 23).
Fail
Safe/Secure
Brake Release Pin
(remove cover
to access)
Safety
UL
Radio
Charger
Charger
Loop
Sensor
Rec.
Power
Power
Low Battery
Low Battery
Motor Sensor
Motor Sensor
Mag.
Lock
N.C.
COM
Safety Connector
Loop Connector
N.O.
Radio Station
Radio Station
Charger
Charger
Power
Power
Low Battery
Low Battery
Motor Sensor
Motor Sensor
Mag.
Lock
N.C.
COM
N.O.
Radio Station
Radio Station
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents