DEFAULT SETTINGS AND SPECIFICATIONS
MAXIMUM MOTOR RUN TIME
COURTESY LIGHT TIME
OBSTRUCTION FORCE MARGIN
AUTO CLOSE TIME
INPUT VOLTAGE:
MOTOR TYPE:
MOTOR VOLTAGE:
MAXIMUM DOOR OPENING:
OPENER MAXIMUM RUN TIME:
MAXIMUM LIFTING FORCE:
RECEIVER TYPE:
RECEIVER CODE STORAGE CAPACITY:
TRANSMITTER FREQUENCY:
CODING TYPE:
No. of CODE COMBINATIONS:
CODE GENERATION:
PTX-4 TRANSMITTER BATTERY:
EAT-1 TRANSMITTER BATTERY:
GLOBE:
Note:
1. The maximum door opening on which the SecuraLift
balanced. A person should be able to lift the door up manually with very little effort in case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure on the door
and tracks which may in turn trigger the safety obstruction detection system intermittently.
FACTORY DEFAULT SETTINGS
TECHNICAL SPECIFICATIONS
WIDTH:
1,2
HEIGHT:
WEIGHT:
can be installed is 5100mm wide by 2400mm high. The door must be well
®
DEFAULT
30 Secs.
3 Mins.
2
0 Secs.
230V - 240V AC 50Hz
1/3 H.P. (AC) Alternating Current
230V - 240V AC
5100mm
2400mm
100Kg
30 Secs.
200N (20Kg)
UHF 433.92 MHz. AM Receiver
23 x 4 Button Transmitter Codes
433.92 MHz
Hopping Code
Over 4.29 Billion Random Codes
Non-linear Encryption Algorithm
A23 Alkaline 12 Volts
CR1220 Lithium 3 Volts
Edison (screw mount) 240V 60W
Rough Service (or construction type)
21
STEP
MAXIMUM
—
10 Secs.
10 Mins.
1
5 Secs.
4 Mins.
—
13