Before connecting, preparing or using
equipment, read Section 1: Safety Precautions.
4.1 CONNECTING THE EQUIPMENT TO
THE MAIN SUPPLY
The equipment is shipped without an installed
plug.
For the A 225 AC/DC, use a plug that is suitable
for carrying the amps indicated on the data plate.
For the A 250 AC/DC, install a #8 or larger input
power cord to the internal connections indicated in
section 4.5. Use a plug that is suitable for carrying
the amps indicated on the data plate.
Check to ensure that the power outlet is equipped
with a fuse that is capable of carrying the amps
indicated on the data plate of this unit.

4.2 SELECTING A LOCATION

Special installation may be required
where gasoline or volatile liquids are present
(See NEC Article 511 or CEC Section 20). Do
not move or operate this equipment where it
could tip over. When selecting a location for
this equipment, ensure that the following
guidelines are followed.
1. Use data plate to determine input power
requirements.
2. The operator must have unobstructed access to
all controls and equipment connections.
3. Do not position equipment in small, closed
places. Ventilation of the power source is
extremely important. Make sure that the louvers
on the side panels are not obstructed and that
there is no risk of obstruction during operation.

4. INSTALLATION

4.3 CONNECTION AND PREPARATION OF
11
4. Avoid areas where dust or other objects could
be sucked into the system.
5. Equipment must not obstruct corridors or work
activities of other personnel.
7. Position the power source securely to avoid
falling or overturning.
8. Understand the risk of falling equipment situat-
ed in overhead positions.
EQUIPMENT FOR STICK-ELECTRODE

WELDING.

Connect all welding accessories carefully to
prevent power loss. Carefully follow safety pre-
cautions described in section 1.
T U R N O F F W E L D E R B E F O R E M A K I N G
CONNECTIONS.
DC MODE
1. Connect the ground cable to the negative
receptacle and locate the ground clamp near
the welding zone.
2. Connect the electrode cable to the positive
receptacle and fit the selected welding elec-
trode into the electrode holder.
3. Use the above connection for welding elec-
trodes that use DCEP (Reverse Polarity) weld-
ing current. Reverse the connection for welding
electrodes that use DCEN (Straight Polarity)
welding current.
AC MODE
1. Connect the ground cable and the electrode
cable to the AC receptacles.
2. Fit the selected welding electrode into the elec-