Technical Description; Description; Technical Specifications; Accessories - Air Liquide Saf-Fro PRESTOJET 1K Safety Instruction For Use And Maintenance

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
1.0

TECHNICAL DESCRIPTION

1.1

DESCRIPTION

The system is a modern direct current generator for plasma arc
cutting, created thanks to the application of the inverter. This spe-
cial technology allows for the construction of compact, light weight
generators with high performance. Possibility of adjustment, high
efficiency and reduced power consumption make it an excellent
tool, able to execute quality cutting up to thicknesses of 10 mm.
The generator is equipped with automatic arc restart, which en-
ables optimum cutting of metal grid structures. The generator also
features safety systems that inhibit the power circuit when the op-
erator comes into contact with live parts of the machine. Cutting of
thicknesses up to 1 mm with just the pilot arc is also possible; this
is very useful with painted metals to which the positive pincer can-
not be connected.
WARNING: DURING WORKING TIME, DUE TO THE HUMIDITY
OF AIR, IT IS POSSIBLE TO HAVE EMISSION OF WATER
FROM THE TORCH. THIS ISN'T A DEFECT AND NOT REDUCE
THE QUALITY OF CUT NETHER THE LIFE OF WEAR PARTS.
1.2

TECHNICAL SPECIFICATIONS

DATA PLATE
Single phase supply
Frequency
Effective consumption
Maximum consumption
SECONDARY
Open circuit voltage
Cutting current

Duty cycle 25%

Duty cycle 60%
Duty cycle 70%
Protection class
Insulation class
Weight
Dimensions
European Standards
1.3

ACCESSORIES

Consult the area agents or the dealer.
1.4
DUTY CYCLE
The duty cycle is the percentage of 10 minutes that the power
source can cut at its rated current, considering an ambient tem-
perature of 40° C, without the thermostatic protector cutting in. If
it does cut in, the user has to wait for power source reinstatement
before resuming cutting (see page II).
DO NOT EXCEED THE MAXIMUM WORK CYCLE. EXCEED-
ING THE WORK CYCLE SPECIFIED ON THE DATAPLATE
CAN DAMAGE THE POWER SOURCE AND INVALIDATE THE
WARRANTY.
2.0

INSTALLATION

IMPORTANT: BEFORE CONNECTING, PREPARING OR US-
ING EQUIPMENT, READ SECTION SAFETY PRECAUTIONS.
2.1
CONNECTING THE POWER SOURCE TO THE MAINS
ELECTRICITY SUPPLY.
Check that the power socket is equipped with the fuse indicated in the
technical data table on the power source. All power source models
are designed to compensate power supply variations. For variations
of +-10%, a cutting current variation of +-0,2% is created.
B E F O R E I N S E R T I N G T H E M A I N S
PLUG, IN ORDER TO AVOID THE FAIL
OF POWER SOURCE, CHECK IF THE
M A I N S C O R R E S P O N D S T O T H E
WISHED MAIN SUPPLY.
TECHNICAL DESCRIPTION
PRIMARY
230 V +- 10%
50/60 Hz
11,5 A
22,4 A
300 V
10 A ÷ 30 A
30 A
20 A
15 A
IP 23
H
16 Kg
470 x 205 x 370 mm
EN 60974.1 / EN 60974.7
EN 60974.10
Verify the connection point is able to supply the power requested.
Set the equipment in accordance with folowing table
WARNING: THIS EQUIPMENT DOES NOT COMPLY WITH IEC
61000-3-12. IF IT IS CONNECTED TO A PUBLIC LOW VOLT-
AGE SYSTEM, IT IS THE RESPONSIBILITY OF THE INSTALL-
ER O R USE R O F T HE E Q UI PM E NT T O ENS UR E, B Y
CONSULTATION WITH THE DISTRIBUTION NETWORK OP-
ERATOR IF NECESSARY, THAT THE EQUIPMENT MAY BE
CONNECTED.
THIS CLASS A EQUIPMENT IS NOT INTENDED FOR USE IN
RESIDENTIAL LOCATIONS WHERE THE ELECTRICAL POW-
ER IS PROVIDED BY THE PUBLIC LOW-VOLTAGE SUPPLY
SYSTEM. THERE MAY BE POTENTIAL DIFFICULTIES IN EN-
SURING ELECTROMAGNETIC COMPATIBILITY IN THOSE
LOCATIONS, DUE TO CONDUCTED AS WELL AS RADIATED
DISTURBANCES.
NO MOTOR GENERATOR COMPATIBILITY
In case of use a extension cable, verify the ratio section/length is
in accordance with table below
2.2

POWER SOURCE POSITIONING

SPECIAL INSTALLATION MAY BE REQUIRED WHERE GAS-
OLINE OR VOLATILE LIQUIDS ARE PRESENT. CONTACT
THE COMPETENT AUTHORITIES. WHEN POSITIONING
EQUIPMENT, ENSURE THAT THE FOLLOWING GUIDELINES
ARE FOLLOWED:
1.
The operator must have unobstructed access to controls and
equipment connections.
2.
Check that the power cable and fuse of the socket for power
source connection is suited to current requirements of the lat-
ter.
3.
Do not position equipment in confined, closed places. Venti-
lation of the power source is extremely important. Avoid
dusty or dirty locations, where dust or other debris could be
aspirated by the system.
4.
Equipment (including connecting leads) must not obstruct
corridors or work activities of other personnel.
5.
Position the power source securely to avoid falling or over-
turning. Bear in mind the risk of falling of equipment situated
in overhead positions.
WARNING: THIS PLASMA CUTTER CANNOT BE USED IN
WET CONDITIONS (RAIN OR SNOW). THE PLASMA CUTTER
CAN BE STORED OUTSIDE BUT IS NOT DESIGNED FOR UN-
PROTECTED USE IN WET CONDITIONS.
2 EN
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

800035608

Table of Contents