User Specified Intercharacter Delay; Interfunction Delay - Datalogic PowerScan 7000 2D Product Reference Manual

Hide thumbs Also See for PowerScan 7000 2D:
Table of Contents

Advertisement

Intercharacter, Interfunction, and Intermessage Delays

User Specified Intercharacter Delay

An intercharacter delay of up to 495 milliseconds may be placed after the
transmission of a particular character of scanned data. Scan the Delay
Length bar code below, then scan the number of milliseconds and the
SAVE bar code using the
of this manual.
Programming Chart on page B-5
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex
value for the ASCII character that will trigger the delay
ASCII Conversion
.
Chart (Code Page 1252) on page A-4
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length bar code, and set the num-
ber of steps to 0. Scan the SAVE bar code using the
Programming Chart
of this manual.
on page B-5

Interfunction Delay

An interfunction delay of up to 495 milliseconds may be placed between
the transmission of each segment of the message string. Scan the Inter-
function Delay bar code below, then scan the number of milliseconds
and the SAVE bar code using the
of this
Programming Chart on page B-5
manual.
Prefix
Scanned Data
Suffix
STX
1
HT
2 3 4 5
CR
LF
Interfunction Delays
Interfunction Delay
To remove this delay, scan the Interfunction Delay bar code, then set the
number of steps to 0. Scan the SAVE bar code using the
Programming
of this manual.
Chart on page B-5
Product Reference Guide