Rs-232 Handshaking - Datalogic PowerScan 7000 2D Product Reference Manual

Hide thumbs Also See for PowerScan 7000 2D:
Table of Contents

Advertisement

RS-232 Modifiers

RS-232 Handshaking

RS-232 handshaking is a set of rules concerning the exchange of data
between serially communicating devices.
If using RTS/CTS handshaking, the imager issues an active RTS signal
to the receiving device. The imager waits to send its data until it detects
an active CTS signal from the receiving device. The imager then sends
its data while checking the CTS signal before the transmission of each
data character. If an inactive CTS signal is detected at any time, the
imager halts transmission until it detects another active CTS signal.
When the imager has finished transmitting data, it issues an inactive
RTS signal to the receiving device. Default = RTS/CTS Off, XON/XOFF
Off, and ACK/NAK Off.
RTS/CTS On
* RTS/CTS Off
XON/XOFF On
* XON/OFF Off
ACK/NAK On
* ACK/NAK Off