Code Verifier; Outputs - Pepperl+Fuchs FUQ-B8 Manual

Table of Contents

Advertisement

VB24

4.5.1 Code Verifier

If the VB24 is used as a Code Verifier, the verifier code can be configured in software through
the Genius™ configuration program. However it is also possible to use one of the inputs to
trigger when the scanner should store a code read as the verifier code.
The Code Verifier parameter must be enabled, and the configuration parameters to allow
correct Code Type reading must be saved to the scanner in order to read the verifier code.
When the selected input is activated, the next read code will be stored as the verifier code in
the scanner's non-volatile (Flash) memory.

4.6 OUTPUTS

Two general purpose outputs are available.
CBX100/500
+V
O1+
O1-
O2+
O2-
-V
The meaning of the two outputs Output 1 and Output 2 can be defined by the user (No Read,
Right, Wrong, etc.). Refer to the Genius™ Help On Line.
By default, Output 1 is associated with the No Read event, which activates when the code
signaled by the external trigger is not decoded, and Output 2 is associated with the Complete
Read event, which activates when all the selected codes are correctly decoded.
The output signals are fully programmable being determined by the configured
Activation/Deactivation events, Deactivation Timeout or a combination of the two.
Function
Power Source - Outputs
Output 1 +
Output 1 -
Output 2 +
Output 2 -
Power Reference Outputs
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb24