Pepperl+Fuchs FUQ-B8 Manual page 19

Table of Contents

Advertisement

VB24
Focus Lock/Unlock
You must perform the Focus Lock procedure to save the mechanical focus position to
memory. If the mechanical focus position is changed by more than the allowed tolerance of
the value in memory, a diagnostic alarm will be sent to the display.
1. Enter the Focus Lock function by holding the Mode push button pressed until the FOCUS
LOCK LED is on.
2. Release the button to enter the Focus Lock function.
Once entered, the scanner automatically performs the Lock (saving) or Unlock procedure
depending on the previous state of the Locked Position parameter.
READY
GOOD
SETUP
TRIGGER
LEARN
COM
TEST
STATUS
Figure 7 – Mode Interface: Focus Lock/Unlock Function
The scanner will restart at the end of the process.
If your application has been configured using Mode, go to STEP 6.
NOTE
Reset Scanner to Factory Default (Optional)
If it ever becomes necessary to reset the scanner to the factory default values, you can
perform this procedure by holding the Mode push button pressed while powering up the
scanner. At the end of the procedure (about 5-6 seconds), the Configuration and
Environmental parameters are reset, all LEDs blink simultaneously 3 times and the message
"Default Set" is shown on the display.
FOCUS
green
green
yellow
yellow
red
The procedure is as follows:
A) enter the Focus Lock function
B) wait until the "Focus locked at..."
message appears on the display
(indicating the focus position has
been
saved
to
following parameters are set:
Locked Position = your mechanical
setting
Focus Displacement (Alarm) = set
(default to display only)
memory).
The
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb24