4.3.3 ID-NET™ Network Termination
The network must be properly terminated in the first and last scanner of the network. This is
done by setting the ID-NET™ Termination Resistance Switch in the CBX100/500 to ON.

4.4 AUXILIARY RS232 INTERFACE

The auxiliary serial interface is used exclusively for RS232 point-to-point connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined using the Genius™ utility
program or Genius™ based Host Mode Programming.
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for
device configuration or communication monitoring.
If permanent system wiring is required, the following pins are used to connect the RS232
auxiliary interface:
CBX100/500
RX
TX
SGND
Do not connect the Aux Interface to the CBX spring clamp connectors and
the 9-pin connector simultaneously.
NOTE
5
9
Figure 31 - 9-pin female connector
Function
Auxiliary Interface Receive Data
Auxiliary Interface Transmit Data
Auxiliary Interface Reference
Figure 32 - RS232 Auxiliary Interface Connections
1
6
USER INTERFACE
RX TX
Reference
47