Basic Operation
H Setting Frequency References 1 through 16 and the Inching
Frequency Command (n024 through n031, n120 through
n127)
Frequency references 1 through 16 and an inching frequency command can be set
together in the Inverter (using registers n024 through n31, n120 through n127).
D Setting Frequency References 1 through 16 (n024 through n31, n120
through n127)
Frequency Reference 1
n024
Setting
0.00 to max. frequency
range
Frequency Reference 2
n025
Setting
0.00 to max. frequency
range
Frequency Reference 3
n026
Setting
0.00 to max. frequency
range
n027
Frequency Reference 4
Setting
0.00 to max. frequency
range
Frequency Reference 5
n028
Setting
0.00 to max. frequency
range
Frequency Reference 6
n029
Setting
0.00 to max. frequency
range
5-20
Register 0118
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Register 0119
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Register 011A
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Register 011B
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Register 011C
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Register 011D
Hex
Unit of
0.01 Hz
setting
(see
note 1)
Chapter 5
Changes during
Yes
operation
Default setting
6.0
Changes during
Yes
operation
Default setting
0.00
Changes during
Yes
operation
Default setting
0.00
Changes during
Yes
operation
Default setting
0.00
Changes during
Yes
operation
Default setting
0.00
Changes during
Yes
operation
Default setting
0.00