Engineering Menu; Contents Of Engineering Menu - Sony CCU-900 Installation And Maintenance Manual

Camera control unit
Hide thumbs Also See for CCU-900:
Table of Contents

Advertisement

2-3. Engineering Menu

Use the engineering menu to adjust the boards.
The set data except the SEQ H/V setting is stored in EEPROM of each board.
The SEQ H/V setup data is stored in NV-RAM on the AT-122 board.
To enter the engineering menu, set the MENU ON/OFF switch to ON while pressing the rotary encoder.

2-3-1. Contents of Engineering Menu

Engineering Menu Entry Display
* Engineering Menu *
DA1
DA2
DA3
>Others
Menu
Function
DA1
Sets the output signal level of the WF1/PIX1 connector.
DA2
Sets the output signal level of the WF2/PIX2/PROMPTER connector
DA3
Adjusts the analog input of the IF-730 board.
Others
H-Phase/Y-Mix Gain adjustment and SEQ setting.
DA1 Display
* DA1 *
PIX1 Gain
PIX1 DC
>WFM1 Gain
WFM1 DC
EEPROM Store
Item
Setup
PIX1 Gain
0 to 255
PIX1 DC
0 to 255
WFM1 Gain
0 to 255
WFM1 DC
0 to 255
EEPROM Store
Rotate the rotary encoder to
move the cursor and press the
rotary encoder twice to execute.
CCU-900/900P IMM
80
A2
80
A2
Function
Adjusts the output signal level of the PIX1 connector.
Adjusts the DC level of the PIX1 connector.
Sets the output signal level of WF1 connector.
Adjusts the DC level of the WF1 connector.
Saves the set value in EEPROM of the DPR-69 board.