3-3. Video Signal System
3-3-9. Mode Control Setting from the
REMOTE Connector
When BVP-9500WS/9500WSP is connected, the x 1/x 3
mode can be switched from the INCOM REMOTE
connector of the rear panel of the unit.
When 16 : 9/4 : 3 switchable camera is connected, the 16 :
9/4 : 3 mode can be switched from the MIC REMOTE
connector of the rear panel of the unit.
x 1/x 3 Mode Control
The x 1/x 3 mode can be switched from the INCOM
REMOTE connector by setting ENABLE as shown in the
following table.
n
When ENABLE setting is performed (when setting pin-23
of the INCOM REMOTE connector to the GND level from
the external), the CCU of the x 1/x 3 mode setting is valid
and settings of the MSU and BVP-9500WS/9500WSP are
invalid.
INCOM REMOTE
Signal
Connector Pin No.
x 1/x 3 IN
20
23
x 1/x 3 ENABLE
16 : 9/4 : 3 Control
The 16 : 9/4 : 3 mode can be switched from the MIC
REMOTE connector by turning off the S1002-1 switch on
the AT-122 board and setting ENABLE as shown in the
following table.
n
When ENABLE setting is performed (when setting pin-12
of the MIC REMOTE connector to the GND level from the
external), the CCU of the 16 : 9/4 : 3 mode setting is valid
and settings of the MSU and camera are invalid.
MIC REMOTE
Signal
Connector Pin No.
12
16 : 9/4 : 3
SELECT EN IN
13
16 : 9/4 : 3
SELECT IN
3-14 (E)
Specifications
+5 V (OPEN) : x 1
GND :
x 3
+5 V (OPEN) : DISABLE
GND :
ENABLE
Specifications
+5 V (OPEN) : DISABLE
GND :
ENABLE
+5 V (OPEN) : 4 : 3
GND :
16 : 9
CCU-900/900P IMM