Displaying the Amount of Time Remaining Before a Scheduled Reload
To display how much time is remaining before a scheduled system reload, enter the following command from any
level of the CLI:
FESX424 Switch# show reload

Canceling a Scheduled Reload

To cancel a scheduled system reload using the CLI, enter the following command at the global CONFIG level of
the CLI:
FESX424 Switch# reload cancel

Diagnostic Error Codes and Remedies for TFTP Transfers

If an error occurs with a TFTP transfer to or from a Foundry Layer 2 Switch or Layer 3 Switch, one of the following
error codes displays on the console.
Error
Message
code
1
Flash read preparation failed.
2
Flash read failed.
3
Flash write preparation failed.
4
Flash write failed.
5
TFTP session timeout.
6
TFTP out of buffer space.
7
TFTP busy, only one TFTP session can be
active.
8
File type check failed.
December 2005
Updating Software Images and Configuration Files
Explanation and action
A flash error occurred during the
download.
Retry the download. If it fails again,
contact customer support.
TFTP failed because of a time out.
Check IP connectivity and make sure the
TFTP server is running.
The file is larger than the amount of room
on the device or TFTP server.
If you are copying an image file to flash,
first copy the other image to your TFTP
server, then delete it from flash. (Use the
erase flash... CLI command at the
Privileged EXEC level to erase the image
in the flash.)
If you are copying a configuration file to
flash, edit the file to remove unneeded
information, then try again.
Another TFTP transfer is active on another
CLI session, or Web management
session, or IronView Network Manager
session.
Wait, then retry the transfer.
You accidentally attempted to copy the
incorrect image code into the system. For
example, you might have tried to copy a
Chassis image into a Stackable device.
Retry the transfer using the correct image.