Foundry Configuration Guide for the FESX, FSX, and FWSX
Message Level
Message
Alert
Management module at slot <slot-num>
state changed from <module-state> to
<module-state>.
Alert
OSPF LSA Overflow, LSA Type =
<lsa-type>
Alert
OSPF Memory Overflow
Alert
Power supply <num>, <location>, failed
Alert
Temperature <degrees> C degrees, warning
level <warn-degrees> C degrees, shutdown
level <shutdown-degrees> C degrees
A - 12
Table A.3: Foundry Syslog Messages (Continued)
© Foundry Networks, Inc.
Explanation
Indicates a state change in a management
module.
The <slot-num> indicates the chassis slot
containing the module.
The <module-state> can be one of the
following:
•
active
•
standby
•
crashed
•
coming-up
•
unknown
Indicates an LSA database overflow.
The <lsa-type> parameter indicates the type
of LSA that experienced the overflow
condition. The LSA type is one of the
following:
•
1 – Router
•
2 – Network
•
3 – Summary
•
4 – Summary
•
5 – External
OSPF has run out of memory.
A power supply has failed.
The <num> is the power supply number.
The <location> describes where the failed
power supply is in the chassis.
Indicates an overtemperature condition on
the active module.
The <degrees> value indicates the
temperature of the module.
The <warn-degrees> value is the warning
threshold temperature configured for the
module.
The <shutdown-degrees> value is the
shutdown temperature configured for the
module.
December 2005