11. TROUBLE SHOOTING GUIDE

Error/Code
Description
Display not functioning
after connecting power
E1
Message failure
E6
Burst clash
E2
No sensor signal
Possible Solutions
1. Check fuse
2. Ensure the wires of the power switch, fuse, control board and
the transformer are connected correctly.
3. Ensure the wire from the display to the control board is
connected properly. Remove the upright tube and check the
connection between each wire. Ensure each wire is completely
plugged in; if wires are damaged please change the wire.
4. Check the condition of the transformer
1. The wires from computer and bottom control board are not
properly connected, please check each wire. Replace if
damaged.
2. Check condition of the control board
3. Check the condition of the transformer
1. Ensure power is correct, if not, use correct power to test.
2. Check if the lower control board is burnt out, if burnt out replace,
then reconnect the motor wire.
3. Ensure correct voltage is used
1. The sensor signal was not detected within 10 seconds. Check
the sensor plug connection
2. See if the magnetic sensor is broken or damaged, test the
connection or change the sensor.