Warning And Failure Indications - Becker AR6201 Installation And Operation Manual

Ar6201 series
Table of Contents

Advertisement

Note:
This page is not available if in Installation Setup the dimming
input is set to 14 V or 28 V. Dimming control by the aircrafts
dimming circuit is at this selection performed.
Another press on the "MDE" key change to SQUELCH and by means of the
"ROTARY ENCODER", the setting can be changed. The Active Frequency stays
indicated in the top line of the display and on the bottom line
"SQUELCH" label appears together with a bar graph and a figure showing
the current value.
The squelch threshold can be changed from 6 to 26 by means of the
"ROTARY ENCODER".
Adjustment 6 makes very week and noisy signals audible. Squelch opens at
about -105 dBm.
Adjustment 26 makes only quite strong signals with low noise content
audible. Squelch opens at about -87 dBm.

3.14 Warning and Failure Indications

Display Contents
Reappear every 5 seconds.
Page 3-18
AR6201-(X0X)
Description
"LOW BATT" appears after the supply voltage
of the transceiver dropped below the
threshold defined in the Installation Setup.
Transceiver still operates. Depending on the
aircrafts supply voltage the transceiver may
have a reduced performance. Below 10 volts
the speaker output is switched "OFF"!
Possible reasons for indication:
- Problems with battery capacity (gliders),
- Power interrupts,
- General problem of power supply,
- Wrong (too high) adjusted threshold in
Installation Setup (refer to LOW BATTERY TRH
page in chapter 2.8.5).