Becker AR 3209 Series Installation And Operation Manual

Hide thumbs Also See for AR 3209 Series:
Table of Contents

Advertisement

Quick Links

Becker Flugfunkwerk GmbH • Baden Airpark • 77836 Rheinmünster • Germany
Telephone +49 (0) 7229 / 305-0 • Fax +49 (0) 7229 / 305-217
http://www.becker-avionics.com • Email : info@be cker-avionics.de
Trans cei ver
AR 3209 - ( )
Up wards se ri al no.: 150
In stal la ti on and Ope ra ti on
Ma nu al
DV 37502.03
Is sue 1
Ja nua ry 1999
VHF

Advertisement

Table of Contents
loading

Summary of Contents for Becker AR 3209 Series

  • Page 1 Ma nu al DV 37502.03 Is sue 1 Ja nua ry 1999 Becker Flugfunkwerk GmbH • Baden Airpark • 77836 Rheinmünster • Germany Telephone +49 (0) 7229 / 305-0 • Fax +49 (0) 7229 / 305-217 http://www.becker-avionics.com • Email : info@be cker-avionics.de...
  • Page 2 Date : Page No.: Date : Tit le 01/99 1 -I - 1-II 01/99 1-1 - 1-10 01/99 2-I - 2-II 01/99 2-1 - 2-12 01/99 3-I - 3-II 01/99 3-1 - 3-14 01/99 © 1999by Becker Flugfunkwerk All rights reserved...
  • Page 3: Table Of Contents

    AR 3209 - ( ) Tab le of con tents Sec ti on I GE NE RAL DES CRIP TI ON Page In tro duc ti on Pur po se of equip ment Ge ne ral des crip ti on Va riants sur vey Tech ni cal data 1.5.1...
  • Page 4 AR 3209 - ( ) Blank Page 1-II DV 37502.03/04 Is sue 01/99...
  • Page 5: In Tro Duc Ti On

    AR 3209 - ( ) Sec ti on GE NE RAL DES CRIP TI ON In tro duc ti on The fol lo wing ma nu al des cri bes the VHF trans cei ver AR 3209 - ( ) up wards se ri al no. 150. The ma nu - als DV 37502.03 (“In stal la ti on and Ope ra ti on”) and DV 37502.04 (“Main ten an ce and Re pair”) con tain the fol lo wing sec ti on : Sec ti on...
  • Page 6 AR 3209 - ( ) Af ter it is swit ched on, the unit per forms a self test. All seg ments of the dis plays flash du ring the self test. If faults are de tec ted, the LCD’s (li quid crys tal dis play) dis plays a fault code for ap pro xi ma te ly five se - conds.
  • Page 7: Va Riants Sur Vey

    AR 3209 - ( ) Va riants sur vey Type de sig na ti on Po wer supp ly Trans mit ter out put Pa nel lighting Pa nel co lour Part-No.: vol ta ge ≥ 5 W AR 3209 - (09) - 110 13,75 V 13,75 V / schwarz...
  • Page 8: Ge Ne Ral Data Ar 3209 -(09) Ar 3209

    AR 3209 - ( ) 1.5.2 Po wer supp ly data AR 3209 - (11) No mi nal supp ly vol ta ge 13.75 V.d.c. Supp ly vol ta ge ran ge 12.4 V to 15.1 V Emer gen cy ope ra ti on 10.0 V No mi nal supp ly vol ta ge 27.5 V.d.c.
  • Page 9: Di Men Sions Ar 3209 - (09) Ar 3209 - (11

    AR 3209 - ( ) 1.6.1 Di men sions AR 3209 - (09) AR 3209 - (11) Front pa nel 146 mm x 47,5 mm Depth of unit wit hout ca ble con nec tor 194 mm Weight AR 3209 - (09) 1 kg AR 3209 - (11) 1,2 kg...
  • Page 10: Trans Mit Ter Data Ar 3209 - (09) Ar 3209 - (11

    AR 3209 - ( ) 1.6.3 Trans mit ter data AR 3209 - (09) AR 3209 - (11) ≥ 5 W into 50 Ω Trans mit ter out put AR 3209 - (09) ≥ 2 W into 50 Ω at 10.0 V ope ra ting vol ta ge (emer gen cy mode) ≥...
  • Page 11: Soft Wa Re

    AR 3209 - ( ) 1.6.4 Soft wa re The fre quen cy pro ces sing, fre quen cy sto ra ge and fre quen cy dis play are con trol led by mi cro pro ces - sors. The soft wa re was clas si fied as Ca te go ry “ESS EN TI AL” Le vel 2 in agree ment with the EU RO - CAE/RTCA Do cu ment ED12A/DO-178A.
  • Page 12: En Vi Ron Men Tal Qua Li Fi Ca Ti On Form

    AR 3209 - ( ) En vi ron men tal Qua li fi ca ti on Form The fol lo wing per for man ce stan dards un der en vi ron men tal test con di tions have been estab lis hed in ac cor dan ce with the pro ce du res set forth in EU RO CAE/RTCA Do cu ment No.
  • Page 13: Ac Ces So Ries

    AR 3209 - ( ) 1.10 Ac ces so ries Unit con nec ti on Ca ble so cket 25 pin Ar ti cle no. 0725.021.277 Con nec tor hou sing Ar ti cle no. 0775.479-277 Ca ble so cket 15 pin Ar ti cle no.
  • Page 14 AR 3209 - ( ) BLANK Page 1-10 DV 37502.03/04 Issue 01/99...
  • Page 15 AR 3209 - ( ) Tab le of con tents Sec ti on IN STAL LA TI ON Page Ge ne ral Te sting be fo re in stal la ti on 2.2.1 Ge ne ral 2.2.2 Vi su al in spec ti on Me cha ni cal in stal la ti on 2.3.1 Me cha ni cal in stal la ti on of VHF trans cei ver.
  • Page 16 AR 3209 - ( ) Page Fig. 2-1 In ter wi ring pa nel lighting Fig. 2-2 In ter nal au to ma tic cut-out Fig. 2-3 Po si ti on of vol ta ge chan geo ver switch Fig. 2-4 Po si ti on of dil swit ches S1 - S3 for a par ti cu lar mi cro pho ne Fig.
  • Page 17: Sec Ti On Ii In Stal La Ti On Page

    AR 3209 - ( ) Sec ti on IN STAL LA TI ON Ge ne ral The in stal la ti on of the VHF trans cei ver de pends on the type of air craft and its equip ment. The re fo re, only ge ne ral in for ma ti on can be gi ven in this Sec ti on.
  • Page 18: No Tes On Fac To Ry Set Ting (Po Wer Supp Ly)

    AR 3209 - ( ) 2.3.2 No tes on fac to ry set ting (po wer supp ly) AR 3209 - (09) The AR 3209 - (09) VHF trans cei ver is de sig ned for only 13.75 V supp ly and is the re fo re set to this vol - ta ge on de li very.
  • Page 19: Mi Cro Pho Ne Con Nec Ti On

    AR 3209 - ( ) 2.4.2 Mi cro pho ne con nec ti on The VHF trans cei ver en ab les a ma xi mum of two dy na mic mi cro pho nes and two stan dard mi cro pho - nes (d.c.
  • Page 20: Set Ting The Si De To Ne Vo Lu Me

    AR 3209 - ( ) 2.4.8 Set ting the si de to ne vo lu me The si de to ne vo lu me can be di rect ly set on the VHF trans cei ver at any time in the SIDE functi on ser vi ce mode.
  • Page 21: In Ter Nal Au To Ma Tic Cut-Out

    AR 3209 - ( ) 2.4.10 In ter nal au to ma tic cut-out The VHF trans cei ver is fit ted with an au to ma tic cut-out . The re lea sed au to ma tic cut-out is re ac ti vat ed by me ans of a pea ked ob ject.
  • Page 22: Set Ting The Ar 3209 - (11) Supp Ly Vol Ta Ge

    AR 3209 - ( ) 2.5.1 Set ting the AR 3209 - (11) supp ly vol ta ge The 13.75 V/27.5 V supp ly vol ta ges are set using sli de switch S4 on the back of the unit. The VHF trans cei ver is set to 13.75 V on de li very.
  • Page 23: Ohm Spea Ker Con Nec Ti On

    AR 3209 - ( ) 2.5.4 4 Ohm spea ker con nec ti on If the re pla ced VHF trans cei ver was ope ra ted with a 4 Ohm spea ker, dil switch 1 must be set to the top po si ti on 4.
  • Page 24 AR 3209 - ( ) Fig. 2-8 Moun ting di men sions VHF trans cei ver Page 2-8 DV 37502.03/04 Issue 01/99...
  • Page 25 AR 3209 - ( ) Fig. 2-9 In stal la ti on of fas te ner strips DV 37502.03/04 Issue 01/99 Page 2-9...
  • Page 26 AR 3209 - ( ) Fig. 2-10 In ter wi ring of the VHF trans cei ver AR 3209 - ( ) Page 2-10 DV 37502.03/04 Issue 01/99...
  • Page 27 AR 3209 - ( ) Fig. 2-11 In ter wi ring of the VHF trans cei ver AR 3209 - ( ) - AR 2009/AR 2010/AR 2011 DV 37502.03/04 Issue 01/99 Page 2-11...
  • Page 28: Te Sting Af Ter In Stal La Ti On

    AR 3209 - ( ) Te sting af ter in stal la ti on 2.6.1 Ground test with en gi ne shut down a.) Af ter in stal la ti on of the unit, mea su re the an ten na tu ning bet ween the base of the an ten na and the an ten na con nec ting ca ble using a VHF re flec ti on-coefficient me ter (vol ta ge stan ding wave me ter).
  • Page 29 AR 3209 - ( ) Tab le of con tents Sec ti on OPE RA TI ON Page Con trols and in di ca tors 3.1.1 Ope ra ting in struc tions 3.1.1.1 Trans mit/re cei ve mode 3.1.1.2 Ope ra ti on of in ter com mode 3.1.1.3 Au dio au xi lia ry in put 3.1.2...
  • Page 30 AR 3209 - ( ) Blank Page 3-II DV 37502.03/.04 Is sue 01/99...
  • Page 31: Ope Ra Ti On

    AR 3209- ( ) Sec ti on OPE RA TI ON Con trols and in di ca tors Mea ning of sym bols on con trols and in di ca tors Functi on key Se lec ti on of mode. Ex chan ge key Mode 2: Ex chan ge of pre set fre quen cy and ac ti ve fre quen cy.
  • Page 32 AR 3209- ( ) Ad just ment of vo lu me. LCD (li quid crys tal dis play) ele ments (left in di ca ti on) In di ca ti on of ac ti ve trans mis si on/ re cep ti on fre quen cy (ac ti ve fre quen cy). (right in di ca ti on) In di ca ti on of pre set trans mis si on/ re cep ti on fre quen cy (pre set fre quen cy).
  • Page 33: Ope Ra Ting In Struc Tions

    AR 3209- ( ) 3.1.1 Ope ra ting in struc tions a. Swit ching on the VHF trans cei ver. CAU TI ON Do not switch on the VHF trans cei ver when en gi nes are being start ed or shut down. b.
  • Page 34: Ope Ra Ti On Of In Ter Com Mode

    AR 3209- ( ) Whe re the re is acous tic feed back du ring trans mis si on the side tone vo lu me on the VHF trans cei ver must be tur ned down (re fer to Ser vi ce Mode for ad just ment). c.
  • Page 35: Jam Ming Of Trans Mit But Ton

    AR 3209- ( ) 3.1.2 Jam ming of trans mit but ton The VHF trans cei ver is fit ted with a pro tec ti ve cir cuit to pro tect against jam ming of the trans mit but ton or a short cir cuit on the key supp ly line.
  • Page 36: Mode 1

    AR 3209- ( ) 3.2.1 Mode 1 The left dis play in di ca tes the ac ti ve fre quen cy. The right dis play is swit ched off. The ac ti ve fre quen cy can be chan ged with the MHz and kHz fre quen cy se lec tor swit ches. Sto ra ge ope ra ti on a.
  • Page 37: Mode 3 (Dis Plays Of Fi Xed Fre Quen Cies In The Va Ri Ous Chan Nels)

    AR 3209- ( ) 3.2.2 Mode 2 Se lect mode 2 using the MDE key. The last in di ca ted ac ti ve and pre set fre quen cies in each case are dis play ed in the right and left LCDs. The pre set fre quen cy (right LCD) is set using the MHz and kHz fre quen cy se lec tors.
  • Page 38: Ser Vi Ce Mode (Equip Ment Con Fi Gu Ra Tions)

    AR 3209- ( ) Sto ra ge pro cess Pres sing the STO key ac ti va tes a sto ra ge pro cess as des cri bed in Mode 1 (with a slight chan ge). In Mo des 1 and 2 the fre quen cy shown in the left hand dis play re mains ac ti ve re gard less of the sto ra ge pro cess.
  • Page 39 AR 3209- ( ) Cal ling up the ser vi ce mode Switch off the VHF trans cei ver. Hold the mode key (MDE) pres sed and at the same time switch on the unit. The VHF trans cei ver swit ches to the ser vi ce mode wit hout a unit test. SqL ap pe ars in the left in di - ca ti on and the switch on thres hold of the squelch is shown on the right in di ca ti on.
  • Page 40 AR 3209- ( ) Set ting the au dio au xi lia ry le vel Call up the AU functi on using the MDE key. The fol lo wing dis plays ap pe ar: left LC-Display right LC-Display 00 to 63 Stan dard va lue 63 (LO le vel HI) Set the au dio au xi lia ry le vel using the kHz switch (steps of 1) or MHz switch (steps of 10).
  • Page 41 AR 3209- ( ) Re lea se the fre quen cy sto ra ge Call up functi on SF 6 using the MDE key. The fol lo wing dis plays ap pe ar: left LC-Display SF 6 right LC-Display ON or OFF Se lect the re qui red functi on using the kHz switch and sto re the se lec ti on by pres sing the STO key.
  • Page 42 AR 3209- ( ) Set ting the dy na mic mike in put sen si ti vi ty Call up functi on SF 9 using the MDE key. The fol lo wing dis plays ap pe ar. left LC-Display SF 9 right LC-Display 00 bis 63 Stan dard va lue 32 (LO sen si ti vi ty HI)
  • Page 43 AR 3209- ( ) In di ca ti on the soft wa re spec. no.: and chan ge sta tus Call up functi on using the MDE key. The fol lo wing dis plays ap pe ar: left LC-Display soft wa re spec. no.: and chan ge sta tus Mi cro pro ces sor right LC-Display soft wa re spec.
  • Page 44: Sa Fe Ty In Struc Tions

    AR 3209- ( ) Sa fe ty in struc tions The fol lo wing in struc tions must be fol lo wed for safe ope ra ti on of the VHF trans cei ver: p Switch off the unit when star ting or shut ting down en gi nes. p A speech test is to be per for med be fo re start up and it should be no ted that if the speech test is car ried out clo se to the ground sta ti on the re sults may be po si ti ve even if the an ten na ca ble is bro ken or short-circuited.

Table of Contents