Display Contents
Reappear every 5 seconds.
Reappear every 5 seconds.
Reappear every 5 seconds.
DV 14300.03/.04 Issue 5 5/2013
AR6201-(X0X)
Description
"STUCK PTT" indication appears after 120
seconds of continues transmitting. The
transceiver return to Receive Mode even if
the /PTT line is still active (GND).
For initiating a new transmission, the /PTT
line needs first to become inactive (open).
Possible reasons for indication:
- Transmitting more than 120 seconds.
- PTT-key stuck.
- /PTT line permanently grounded (short
circuit in installation).
"TX HOT" indicates the internal device
temperature exceeds + 90°C.
The AR6201-(X0X) still operates, but the
transmitter has reduced RF output power.
Possible reasons for "TX HOT" indication:
- Too hot environmental temperature,
excessive long transmissions times in
insufficient airflow conditions.
The transceiver has detected an internal
failure during normal operation.
Depending on failure reason, the device may
still operates with a degraded performance
or not operate at all.
Possible reasons for indication:
- Out of specified environmental conditions
- HW or SW failure inside the transceiver.
Contact maintenance shop for assistance.
The transceiver has detected an internal
failure during start up.
Depending on failure reason, the device may
still operates with degraded performance or
not operate at all.
Possible reasons for indication:
- Out of specified environmental conditions
- HW or SW failure inside the transceiver.
Contact maintenance shop for assistance.