BECKER FLUGFUNKWERK GMBH
Baden Airpark
D-77836 Rheinmünster (Germany)
Tel.:
+49 (0) 7229 / 305-0
Fax:
+49 (0) 7229 / 305-217
Subject to technical changes
OPERATING INSTRUCTIONS
VHF Transceiver AR 3209

Advertisement

Table of Contents
loading

Summary of Contents for Becker AR 3209

  • Page 1 OPERATING INSTRUCTIONS VHF Transceiver AR 3209 BECKER FLUGFUNKWERK GMBH Baden Airpark D-77836 Rheinmünster (Germany) Tel.: +49 (0) 7229 / 305-0 Fax: +49 (0) 7229 / 305-217 Subject to technical changes...
  • Page 2 © Copyright bei Becker Flugfunkwerk Issue 10/95 Article-No. 891.436-071...
  • Page 3: Table Of Contents

    Operating Instructions Becker AR 3209 Fault description Becker Flugfunkwerk GmbH TABLE OF CONTENTS Baden Airpark, Gebäude B 108 77836 Rheinmünster (Germany) IMPORTANT Tel. +49 (0) 7229 / 305-0 INTRODUCTION +49 (0) 7229 / 305-217 SAFETY INFORMATION Unit type : Serial number :...
  • Page 4 Entry of password to interlock the equipment configuration If an equipment fault the unit may be sent to a Becker Dealer or the Setting the dynamic mike input sensitivity Becker customer service together with a description of the fault. The...
  • Page 5: Issue

    Operating Instructions Becker AR 3209 IMPORTANT General data AR 3209 - (09) / AR 3209 - (11) Carefully read these operating instructions right through before attempting to operate the VHF transceiver. Frequency range 118.000 MHz to 136.975 MHz Keep these operating instructions carefully. They contain important Number of channels safety and operating instructions for the VHF transceiver.
  • Page 6: Mode

    Operating Instructions Becker AR 3209 Technical Data The CAUTION, WARNING and NOTE highlights have the following meanings : Power supply voltage AR 3209 - (09) Nominal supply voltage 13.75 V DC Failure to comply, or incorrect compliance, WARNING Supply voltage range 12.4 V to 15.1 V...
  • Page 7: Safety Information

    Operating Instructions Becker AR 3209 SAFETY INFORMATION Speaker muting switch ON/OFF A speech test is to be performed before startup and it should be noted that if the speech test is carried out close Call up function SF 12 using the MDE key. The following displays...
  • Page 8 Operating Instructions Becker AR 3209 Inhibiting the transmit mode for one or more memory channel Call up function SF 10 using the MDE key (4). The following displays appear : left LC display (7) SF 10 right LC display (8)
  • Page 9: General Information

    Set any 4-digit numerical code using the kHz (10) (steps of 1) or MHz (9) (steps of 10) switch. Store the numerical code by pressing the STO key (3). The VHF transceiver AR 3209 enables voice communication on 760 channels in the 118.000 MHz to 136.975 MHz range with a channel NOTE spacing of 25 kHz.
  • Page 10: Controls And Indicators

    Operating Instructions Becker AR 3209 CONTROLS AND INDICATORS OFF = The storage of frequencies in the individual channels is not possible. The VHF transceiver can only work on set frequency. ON = Storage of frequencies in the individual channels is...
  • Page 11 Operating Instructions Becker AR 3209 Release the frequency setting (channel selection only) Exchange key Mode 2: Exchange of preset frequency and active frequency. Call up function SF 5 using the MDE key (4). The following displays appear : LE diode, green Transmit indication (PTT button pres- sed).
  • Page 12: Operating Instructions

    Operating Instructions Becker AR 3209 OPERATING INSTRUCTIONS Setting the audio auxiliary level Switching on the unit Call up the AU function using the MDE key (4). The following displays appear : CAUTION left LC display (7) right LC display (8)
  • Page 13: Transmit/Receive Mode

    Operating Instructions Becker AR 3209 Setting the squelch threshold The various modes are comprehensively described, toghether with the setting of the equipment configuration in the service mode, in the Annex to the General Operating Instructions. If function S q L is called up, the following displays appear :...
  • Page 14: Operation Of Intercom Mode

    Operating Instructions Becker AR 3209 Set the correct reception volume using the VOL control (1) whilst the Calling up the service mode ground station is answering. Switch off the VHF transceiver. Hold the MDE key (4) pressed and at Switch on the squelch (2) (press SQL key again). Weak reception the same time switch on the unit.
  • Page 15: Audio Auxiliary Input

    Operating Instructions Becker AR 3209 Erasure of stored frequencies Audio auxiliary input COdE Entering a password to interlock the equipment A second and third radio unit (navigational receiver) can be monitored configuration simultaneously via the Audio auxiliary input. During transmission the Dynamic mike input sensitivity auxiliary input is switched off from the Audio end amplifier.
  • Page 16: Operation Of The Various Modes

    Operating Instructions Becker AR 3209 Operation of the various modes In mode 3 (channel selection mode) the actuelly memoried frequency in the left display (7) becomes active frequency The VHF transceiver performs various functions which are covered by individual operating modes. The mode is selected by briefly pressing Note the MDE key (4).
  • Page 17: Mode

    Operating Instructions Becker AR 3209 Mode 3 (Displays of fixed frequencies in the various NOTE channels) When changing mode frequencies (PRESET-ACTIVE frequency) change automatically stored 2 seconds after the last change took Channel selection mode place. Due to this delay changes which were made immediately before switching off the transceiver will not Select the mode using the MDE key (4).
  • Page 18 Operating Instructions Becker AR 3209 The required frequency can be set using the kHz frequency selector Mode 2 switch (10) and MHz frequency selector switch (9). Press STO key (3). The next free channel is shown flashing “ch”. Press Select mode 2 using the MDE key (4). The last indicated active and the STO key (3).