1.6.9

Regulatory Compliance

Part Number
AR6201-(000)
0610.321-910
AR6201-(002)
0614.203-910
AR6201-(100)
0621.218-910
AR6201-(102)
0621.226-910
Note:
Unauthorized changes or modifications to the AR6201-(X0X) may
void the compliance to the required regulatory agencies and
authorization for continued equipment usage.
1.7

Environmental Qualification

Under environmental test condition in accordance with the procedures set
forth in EUROCAE/RTCA Document ED-14E/DO-160E the following performance
has been demonstrated.
Condition
Temperature and Altitude
Ground Survival Low
Temperature
Short-Time Operating Low
Temperature
Operating Low Temperature
High Ground Survival
Temperature
High Short-Time Operating
Temp.
Operating High Temp.
In-flight Loss of Cooling
Altitude
Decompression
Overpressure
Temperature Variation
DV 14300.03/.04 Issue 5 5/2013
AR6201-(X0X)
Article
EASA Approval
Number
EASA.210.1249
ETSO-2C37e
Class: D, E
ETSO-2C38e
Class: 4, 6
EASA.210.1249
ETSO-2C37e
Class: D
ETSO-2C38e
Class: 4
Section
4.0
4.5.1
4.5.2
4.5.3
4.5.4
4.5.5
4.6.1
4.6.2
4.6.3
5.0
TSO Approval
TSO-C169a
Class: D, E,
4, 6
TSO-C169a
Class: D, 4
Cat.
Description
C4
-55 deg C
-20 deg C
-20 deg C
+85 deg C
+70 deg C
+55 deg C
X
No forced cooling required
C4
35,000 ft
B
5°C per minute
FCC Approval
B54AR6201
B54AR6201