Kingsman Marquis Infinite MQRB4436 Installation Instructions Manual page 98

Infinite series “zero clearance” direct vent gas fireplace
Hide thumbs Also See for Marquis Infinite MQRB4436:
Table of Contents

Advertisement

Connect to TH and TH / TP Tabs on Valve
Connect to Power Vent Cable
Connect to Double Pole Switch Cable
Plug into120v AC Outlet
MILLIVOLT POWER VENT CONTROL MODULE
FIREPLACE IS SUPPLIED
WITH ONE JUNCTION BOX.
ADDITIONAL OUTLETS
DOUBLE POLE SWITCH
MAY BE REQUIRED.
(SUPPLIED)
CONSULT A QUALIFIED
ELECTRICIAN.
NOTE: Double Pole Switch can be replaced with 120V Double Pole Thermostat. Contact an Electrician for installation.
*In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative).
SWITCH MUST BE "ON" AND POWER VENT BLOWER MUST BE RUNNING FOR APPLIANCE TO OPERATE.
NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION:
Downward vertical vent runs are NOT permitted.
NOTE: MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION:
Downward vertical vent runs are permitted, however, Cold Climate Switch (Standing Pilot
Mode) must not be used.