Installation Instructions

Model Numbers MDV31/39/MQRB3632
Multi-Sided Direct Vent Decorative Gas Fireplace
Model MDV31 Series - MDVR31N, MDVR31LP, MDVL31N, MDVL31LP, MQRB3632N, MQRB3632LP
Model MDV39 Series - MDVR39N, MDVL39N, MDVR39NE, MDVL39NE Conversion only
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause property
damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Propane Horizontal installations the venting must be a minimum of one foot vertical off the flue before
going horizontal.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Certified to: ANSI Z21.50b-2009, CSA 2.22b-2009, CGA 2.17-M91
MDVR31NE, MDVR31LPE, MDVL31NE, MDVL31LPE, MQRB3632NE, MQRB3632LPE
Certified to: ANSI Z21.50b-2009, CSA 2.22b-2009
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
FOR YOUR SAFETY
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Printed in Canada
March 14, 2014
Part # 31-39-MAN-II

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman MDVR31N

  • Page 1: Installation Instructions

    Multi-Sided Direct Vent Decorative Gas Fireplace Certified to: ANSI Z21.50b-2009, CSA 2.22b-2009, CGA 2.17-M91 Model MDV31 Series - MDVR31N, MDVR31LP, MDVL31N, MDVL31LP, MQRB3632N, MQRB3632LP MDVR31NE, MDVR31LPE, MDVL31NE, MDVL31LPE, MQRB3632NE, MQRB3632LPE Model MDV39 Series - MDVR39N, MDVL39N, MDVR39NE, MDVL39NE Conversion only Certified to: ANSI Z21.50b-2009, CSA 2.22b-2009...
  • Page 2: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 3: Table Of Contents

    Horizontal Venting Routes................50-51 Vertical Venting.................... 52 Replacement Parts..................53-55 Parts List for Models MDV31/39..............Parts List for Model MQRB3632..............Kingsman Fireplace Venting................ 58 Trouble Shooting The Gas Control System..........Glass Safety / Termination Cap Safety- All Units........Limited Lifetime Warranty................
  • Page 4: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CGA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the national Electrical Code;...
  • Page 5: Installation Requirements For The Commonwealth Of Massachusetts

    • Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 6: Locating Your Appliance

    Locating your Appliance Horizontal Run With Min. Vertical MAX. Horizontal Run With Required Vertical Run MAX. 20'-0" 36.0" RIGHT BURNER SYSTEM LEFT BURNER SYSTEM TOP VIEW SEE THRU TOP PENINSULA VIEW LEFT BURNER SYSTEM RIGHT BURNER SYSTEM ALL UNITS CAN BE VENTED VERTICAL LEFT MIN.
  • Page 7: Framing Corner L/H & R/H Installation Instructions - Louvered Unit Only

    Framing Corner L/H & R/H Installation Instructions - Louvered Unit Only FRAMING FRAMING DETAIL Using 2x4s frame to local building codes. THROUGH Combustible WALL DO NOT install against a Vapour Barrier or Exposed Insulation. 11.0" Framing measurements have been adjusted to accommodate a 1/2"...
  • Page 8 FIGURE 3 SIDE BRICK PANEL BRICK PANEL INSTALLATION 1. Insert side Brick panel into place, using Brick retaining clip position and screw to top of firebox. BRICK 2. Install rear Brick panel, brick CLIP retaining clip located at top. REAR BRICK PANEL NOTE! NOTE!
  • Page 9: Framing See-Thru Installation Instructions - Louvered Unit Only

    Framing See-Thru Installation Instructions - Louvered Unit Only FRAMING Using 2x4s frame to local building codes. DO NOT install against a Vapour Barrier or Exposed Insulation. Framing measurements have been adjusted to accommodate a 1/2" thick finished wall. FIGURE 1 FRAMING DETAIL Combustible materials may be installed flush with top HORIZONTAL RUN...
  • Page 10 NOTE! This UNIT is not FACING MATERIAL INSTALLATION Load Bearing Facing material. Example DRYWALL may be installed Flush with top of Fireplace. Side facing to be installed to standoffs only. DRYWALL Gyprock Gyprock...
  • Page 11: See Through With Cvck -Dimensions

    See Through With CVCK -Dimensions- Note: When CVCK is used, a CVCK Kit must be installed on Both sides of the unit. See Through With CVCK -Enclosures- For Propane Horizontal Installations the venting must be a minimum of one foot vertical off the flue before the elbow on any horizontal runs of one foot or greater.
  • Page 12: -See-Through With Cvck Installation

    -See-Through With CVCK Installation- Framing (The following method assumes that framing is in place before the unit is installed.) Using 2x4’s, frame to local building codes. DO NOT install against a Vapor Barrier or Exposed Insulation. Framing measurements have been adjusted to accommodate a ½” thick finished wall. Combustible materials may be installed flush with the top and sides of the installed CVCK Kits.( “Framing and Facing Requirements”...
  • Page 13: Framing & Facing Requirements

    Framing and Facing Requirements See Through with CVCK (Clean View Circulating Kit) Note: When CVCK is used, a CVCK Kit must be installed on Both sides of the unit. MDV31 with MQ36SWF Surround...
  • Page 14: Mdv31 - How To Install Clean View Kit (Z36Cvck)

    MDV31 – How to Install Clean View Kit (Z36CVCK) Caution: When using CVCK do not install Louver Assembly. WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. NOTE: When using the Clean View Kit (CVCK) and installing optional electrical components (i.e.
  • Page 15: Mqsw Wall Mount Surrounds

    MQSW Wall Mount Surround Dimensions MQSW Wall Mount Surround Dimensions Installation of MQ Wall Mount Surrounds Installation of Wall Mount Surrounds 1. Set Surround Lip on CVCK Ledge and ensure that it is securely in place. 2. Swing the upper portion of the Surround so that the Surround Ledge is resting on top of the CVCK Deflector Lip. 3.
  • Page 16: Framing Peninsula Installation Instructions - Louvered Unit Only

    Framing Peninsula Installation Instructions - Louvered Unit Only FRAMING FRAMING DETAIL Using 2x4s frame to local building codes. HORIZONTAL RUN DO NOT install against a Vapour Barrier or Exposed WITH MIN. VERTICAL RUN Insulation. Framing measurements have been adjusted to accommodate a 1/2"...
  • Page 17 FACING MATERIAL INSTALLATION Facing material. Example DRYWALL may be installed Flush with top of DRYWALL Fireplace. Side facing to be installed to standoffs only.
  • Page 18: Low Profile Enclosures - Louvered Unit Only

    Low Profile Enclosures - Louvered Unit Only NOTE NOTE INSULATION SLEEVE MUST WITH USING DURA-VENT COVER 7.0" FLEX PIPE FROM PIPE AND ADAPTER MINIMUM FIREPLACE UP AND TO WALL. HEIGHT OF 52.0" MUST BE SLEEVE FOR LOW PROFILE MAINTAINED FOR PROPER ENCLOSURES MAXIMUM 34.0".
  • Page 19: Clearances - Mdv31 - Mantels & Surrounds

    Clearances – MDV31 – Mantels & Surrounds Clearance to Combustibles Back (of unit) 6 inches /152mm Sides (of unit in framing) 6 inches /152mm Vertical Pipe 1 inch /25mm Back (from standoffs) 0 inches /0mm Side (from standoffs) 0 inches /0mm Floor 0 inches /0mm Ceiling (from bottom of fireplace)
  • Page 20: Mantel Leg Clearances

    Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using the MQ36SWF Surround.
  • Page 21: Fan Kit Installation

    Fan Kit Installation SUGGESTED LOCATION FOR 120V SUGGESTED LOCATION FOR 120V JUNCTION BOX FOR FAN KIT POWER CABLE THERMODISC BOTTOM OF FIREBOX GAS INLET WALL MOUNTED VARIABLE SPEED L/H FIREPLACE SHOWN CONTROL 1. To install fan slide key hole mounts onto both #8 screws, located rear bottom bracket.
  • Page 22: Split Receptacle- Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 23: Door And Grill Installation

    Door and Grill Installation DOOR ASSEMBLY To install all Doors, first install bottom screws into Fireplace. Set slots in bottom of Doors onto screws, slide top of Door onto Fireplace and insert top screws. Tighten bottom and top screws so that they are snug.
  • Page 24: Logc31 Placement Guidelines For Model Mdv31/39

    LOGC31 Placement Guidelines for Model MDV31/39 ❶ ❹ Warning: Failure to position the parts FLAT EMBERS AREA in accordance with these diagrams or NOTCH ❷ failure to use only parts specifically ❺ approved with this appliance may result in ROCK property damage or personal injury.
  • Page 25: Logc31 Placement Guidelines For Model Mdv31/39

    LOGC31 Placement Guidelines for Model MDV31/39 (continued) ❹ ❺ GRATE Step (4) Locate the two mounting holes on the bottom Log #4 and Step (5) Place ‘V’ area of Log#5 onto grate bar and rest log onto flat area position them onto Tabs 4a - 4b. of Log #2.
  • Page 26: Mqrsp7 Rock Support Platform And Mqrock1 For Models Mdv31/39

    MQRSP7 Rock Support Platform and MQROCK1 for Models MDV31/39 Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. MQRSP7 Remove grate bars, log bracket, and bend down all the ember plate tabs.
  • Page 27: Mqrsp7 Rock Support Platform And Mqrock1 For Models Mdv31/39

    MQRSP7 Rock Support Platform and MQROCK1 for Models MDV31/39 Step 5: Place rocks #3 and #6 into Step 4: Place rocks #1 into position as position as shown. shown. Step 6: Place rocks #3 into position as Step 7: Place rock #1 into position as shown.
  • Page 28 Accessories Available for Skyline & ZDVRB3622 Ribbon Burner Units ACCESSORY ITEM MQRB3328 MQRB3632 MQRB4236 ZDVRB3622 Silica Sand 5LB Bag c/w Unit 5LB Bag c/w Unit Not Available Not Available Yes / 5LB MAX Yes / 5LB MAX 5LB Bag c/w Unit MQ Dealer Only White Glass MQG5W Bronze Glass MQG5C...
  • Page 29: Ulk2 Universal Light Kit (Optional Accent Lighting Kit)

     MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom. Be careful not to cover any part of the Burner Tube as sooting may occur. MQRock2 MQRock3 MQRBD1 NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur. ...
  • Page 30 ULK2 Universal Light Kit ( Optional Accent Lighting Kit) For the Skyline Series (MQRB3328, MQRB3632, MQRB4236) and Kingsman ZDVRB3622 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada.
  • Page 31 MQRB3328, ZDVRB3622, & MQRB4236 Screw Screw MQRB3632 Screw Screw STEP 3: Place Lamps in position in firebox. Attach to fireplace with a single screw at the locations shown above for each unit. Lamps can be placed facing upward or sideways. Replace burner tube and false bottom, along with pilot shield.
  • Page 32: Installing Mqrb 3632 Liner Panels

    Installing MQRB 3632 Liner Panels There are several types of Liner Panels available for the MQRB3632: -Flat Black False Bottom and Side Panels, -Supplied with Unit -Porcelain Side Panels- MQRB36PL Removal of Liner Panels Remove all Doors from the fireplace by loosening bottom screws and removing the 2 screws on top of the unit. Remove Side Panel(s) from inside of Firebox.
  • Page 33: Brick Panel Installation

    Brick Panel Installation REMOVAL OF METAL PANEL BEFORE INSTALLING REAR BRICK PANEL 1. Locate 2 screws on bottom rear of unit holding metal panel to firebox bottom, remove the 2 screws and discard. 2. Hold metal panel by the bottom and pull forward and down at the same time. This will release the panel from the holder at the top of the unit.
  • Page 34: Burner And Valve Removal Instructions

    Burner and Valve Removal Instructions Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. for Models MDV31/39 BURNER REMOVAL AND REPLACEMENT 1.
  • Page 35: Gas Line Installation

    Gas Line Installation This gas appliance should be installed by a qualified installer in accor- dance with local building codes and with current CAN/CGA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1.
  • Page 36: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 37: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 38: Conversion Kit Instructions - Part A

    31MDV-CKLP LP Conversion 1001-P167SI 1001-P202SI (for MDVR31LP, 1000-P201VE 1/4” #30 (977.167) -Millivolt- (0.907.202) MDVL31LP) 31MDV –CKNG NG Conversion 1001-P165SI 1001-P201SI (for MDVR31N, 1000-P201VE 3/32” #51 (977.165) -Millivolt- (0.907.201) MDVL31N) 3632RB-CKLP LP Conversion 1001-P167SI 1001-P202SI (for MQRB3632LP) 1000-P201VE 5/16” #30 (977.167) -Millivolt- (0.907.202)
  • Page 39 Gas Conversion –Part A – MDV31 / MDV39 WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instruction s and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 40: Gas Conversion For Top Convertible Pilot (Series 019065X) - Part B

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from NG to LPG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 41: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 42: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 43 the slide switch to the middle [REMOTE] position and then push the small pushbutton to begin programming. Bring the transmitter close to the receiver and then press the power button [R] on the transmitter. An audible beep will sound to indicate the system is programmed and ready to be used. NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4”...
  • Page 44 Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 45 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 46 Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 47: Ipi Lighting Instructions

    IPI Lighting Instructions WARNING 1. If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 2. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed.
  • Page 48: Vent Termination

    (30cm) minimum. This appliance is approved with Kingsman flex vent system and G - Clearance from a perpendicular inside wall or outer corner to also approved for use with Simpson Duravent Direct Vent System the edge of the vent terminal plate is 3”...
  • Page 49: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall FRAMING DIMENSION or vertically through the roof. Only Kingsman Flex(Z-Flex)Venting Kits Combustible Wall and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson- Cut a 11” hole through exterior wall and frame as shown below.
  • Page 50: Horizontal Venting Routes

    Horizontal Venting Routes Venting Routes And Components How To Use The Vent Table Determine the height of the system and the Since it is important that the vent system maintain its number of bends required. balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent Having determined the vertical distance, configurations apply and must be strictly adhered to.
  • Page 51 20 FEET FIGURE 2 SUPPORT STRAPS EVERY 2 FEET 2.5" rise per ft. for horizontal runs with min. vertical from 7 FEET Fireplace. SIDE VIEW 35.0" Important Minimum clearances of For installations other than Low Profile flue pipe to combustibles. Enclosures, top of horizontal with no Vertical runs 1.0".
  • Page 52: Vertical Venting

    Vertical Venting Venting Straight Up Through Roof Roof Flashing 1. An Attic Insulation Shield must be installed where the vent pass- Ensure that you have the proper roof flashing by checking your es from a lower living space into an attic space where the chim- roof pitch using a level and two rulers, or by using a roof pitch ney is not enclosed.
  • Page 53: Replacement Parts

    Replacement Parts 3800-173 3800-170 3800-171 BOTTOM BRICK PANELS NOT AVAILABLE 3800-127 3800-172 3800-138 3600-115 3800-130 3800-115 3800-304 3800-128 3800-129 EMBER-R EMBER-I 3800-303 ZIRC 1000-305 3800-312 1000-306 1000-306 Z1MT 3800-302 3800-132 3600-301 5000-P025WS 1000-150GE (RED) 3800-134 1000-150MP (BLACK) 1000-218...
  • Page 54 Replacement Parts (continued) For Models MDV31/39...
  • Page 55: Replacement Parts

    Replacement Parts (continued) ZDVWT FDVHT FDVVT40 ZDV7FCL ZDV48GP ZDVSS ZDVRS ZDV4SS ZDV7SC ZDVST ZDVAAF ZDVAF2 ZDV7FC ZDVAF3 ZDV4FC ZDVAIS ZDVFK5 ZDVFK8 ZDVFK20 ZDVFS...
  • Page 56: Parts List For Models Mdv31/39

    Replacement Burner Assembly c/w Valve MDV31/39 SERIES MULTI-SIDED DIRECT VENT FIREPLACE: 3100-BRNG Burner Assembly - Right, Natural Gas - For Model MDVR31N Listed for USA/Canada as a Decorative Appliance, Includes: Triple Burner, Up to 3100-BRLP Burner Assembly - Right, Liquid Propane - For Model MDVR31LP...
  • Page 57: Parts List For Model Mqrb3632

    Parts List for Model MQRB3632 PART NO. DESCRIPTION MARQUIS PRODUCTS (for use with Designer Clean View Kit) MQ36SWFBL Wall Surround - Black Fireplace Part Numbers MQ36SWFPW Wall Surround - Pewter MQRB3632 SERIES MULTI-SIDED DIRECT VENT FIREPLACE: MQ36SWAKSB Wall Surround Accents - Keystone Black Listed for USA/Canada as a Decorative Appliance, Includes: Burner, Up to Three Viewing Areas, Milli Volt Sit Valve Featuring less than 30 Sec.
  • Page 58: Kingsman Fireplace Venting

    3632RB-CKNGI NG Conversion Kit for MQRB3632NE (IPI) 1001-P634SI Valve Nova NG Hi/Lo 0820634/652 1001-P713SI Pilot Burner LP 199.713 TC SIT Kingsman Fireplace Venting *In the U.S.A. 1001-P714SI Pilot Burner NG 199.714 TC SIT Thermostats are not permitted for Vented Catalog...
  • Page 59: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 60: Glass Safety / Termination Cap Safety- All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. Optional safety screens are available for most appliances. Check with your dealer to find out if one is available for your unit, or if an aftermarket free standing safety screen is available.
  • Page 61: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents