Kingsman MQRB4436N Installation Instructions Manual

Zero clearance vented gas fireplace
Table of Contents

Advertisement

Model Numbers:
Certified to:
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Refer to this manual. Installation and service
must be performed by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada October 20, 2014
Part# 51MQ-MAN14
Infinite Series

Installation Instructions

MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE
MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE
MQRB6961N, MQRB6961NE, MQRB6961LP, MQRB6961LPE
ANSI Z21.50-2014 • CSA 2.22-2014
ZERO CLEARANCE VENTED GAS FIREPLACE
ZERO CLEARANCE VENTED GAS FIREPLACE
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
If you cannot reach your gas supplier, call the fire department.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MQRB4436N and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman MQRB4436N

  • Page 1: Installation Instructions

    Infinite Series Installation Instructions Model Numbers: MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE MQRB6961N, MQRB6961NE, MQRB6961LP, MQRB6961LPE Certified to: ANSI Z21.50-2014 • CSA 2.22-2014 ZERO CLEARANCE VENTED GAS FIREPLACE ZERO CLEARANCE VENTED GAS FIREPLACE WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents..................................Child Safety Screen -MQRB4436 & MQRB5143…………………………………………………………………………………….. Child Safety Screen – MQRB6961…………………………………………………………………………………………………….. Recommendations for Finishing of Clean View Linear Products..................... Pre-installation Questions and Answers..........................Operating Instructions................................Warnings, Installations and Operations........................... Installation Requirements for the Commonwealth of Massachusetts..................Nailing Tab Guide for all Units..............................
  • Page 3 MQRB5143 Burner Section: Gas Conversion.......................... MQRB4436 / MQRB5143 Burner Tube Removal / Burner System Removal/Installation Guide..........MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace..................MQRB6961 Burner Section: Gas Conversion.......................... MQRB6961 Burner Tube Removal / Burner System Removal/Installation Guide..............Remote Receiver Location...............................
  • Page 4: Child Safety Screen -Mqrb4436 & Mqrb5143

    Infinite Series CSS Child Safety Screen Contents of Kit: [1] Child Safety Screen [2] Screen Mount Brackets [6] 3/8” x 1/2” Screws Assembly Instructions: Fasten Screen Mount Brackets to Child Safety Screen with supplied screws. ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screen.
  • Page 5: Child Safety Screen - Mqrb6961

    MQRB69CSS Child Safety Screen Contents of Kit: [1] Child Safety Screen Bottom Angle [1] Bottom Angle on Bottom of [2] Screen Mount Brackets Screen. [11] 3/8” x 1/2” Screws Assembly Instructions: Fasten Screen Mount Brackets to Child Safety Screen with supplied screws.
  • Page 6: Recommendations For Finishing Of Clean View Linear Products

    Recommendations for Finishing of Clean View Linear Products When finishing the wall around the fireplace, it is critical that the wall covering be fastened properly. It is acceptable to pre-drill holes and use self-tapping screws which may be used to fasten a backer for tile, marble, etc. Screws being installed through non-combustible board should be self-tapping type with a maximum length of 2 inches.
  • Page 7: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Warnings, Installations And Operations

    Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 9: Installation Requirements For The Commonwealth Of Massachusetts

     Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source.  This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home.
  • Page 10: Nailing Tab Guide For All Units

    MQRB4436 / MQRB5143 / MQRB6961 Nailing Tab Guide [Qty] 2 Nailing Tabs are located on each corner of the fireplace. The Nailing Tabs on the MQRB4436, MQRB5143 or MQRB6961 can be used in two ways: 1/2” Drywall Flush with Face of Fireplace –Fireplace and -Fireplace to be covered Framing Flush with Face of Fireplace Combustible Wall to be covered with Non-Combustible...
  • Page 11: Mqrb4436: Framing Your Gas Fireplace

    (see Venting section) for this appliance. Failure to comply with those requirements can seriously compromise the safety and operation of the fireplace. Kingsman Flex venting MUST be used on the MQRB4436. Use of DuraVent- DirectVent Pro or other hard pipe Venting systems is not permitted.
  • Page 12: Mqrb4436 Locating Your Appliance / Fireplace Dimensions

    MQRB4436 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit. Left Burner System Right Burner System All Units Can Be Vented Vertically Horizontal Run With Min.
  • Page 13: Mqrb4436 - Pre-Existing Enclosures Vs Framing Enclosure Around Fireplace

    MQRB4436 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 53-1/2” inside width. Opening should be greater than 46-1/2” minimum. Insert airbox on side of unit first and swing into place. Airbox Framing Enclosure Around Fireplace: If unit is in place before enclosure is built, minimum clearances for opening can be followed.
  • Page 14: Mqrb4436 -See Thru Framing

    MQRB4436 -See Through Framing An MQRB4436SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 15 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1”...
  • Page 16: Mqrb4436 Single Sided Framing

    MQRB4436 Single Sided Framing An MQRB4436BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 17 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1”...
  • Page 18: Mqrb4436 Combustible Enclosure Heights

    7-3/4” Min for Natural Gas 24” Min for Propane 37-1/2” Min for Natural Gas 53-3/4” Min for Propane Kingsman Flex venting MUST be used on the MQRB4436. Single Side Installation Only Use of DuraVent- [Steel Stud Framing Shown.]...
  • Page 19: Mqrb4436 Surround Dimensions / Surround Clearances

    Surround Dimensions MQRB4436 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. • The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials. Surround Clearances MQRB4436...
  • Page 20: Mqrb4436 Facing Material Requirements

    MQRB4436 Facing Material Requirements These specifications are the same for all Models (4436N, 4436NE, 4436LP, 4436LPE). Note: If using Optional Surround, See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
  • Page 21: Mqrb4436 Mantel Clearances / Clearance To Combustibles

    Side & Bottom of Horizontal Pipe 1” All Vent Systems Vertical Vent Pipe 1” All Vent Systems Kingsman Flex venting MUST be used on the MQRB4436. Use of DuraVent- DirectVent Pro or other hard pipe Venting systems is not permitted.
  • Page 22: Mqrb5143: Framing Your Gas Fireplace

    Framing Your Gas Fireplace MQRB5143: This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 23: Mqrb5143 Locating Your Appliance / Fireplace Dimensions

    MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit. Left Burner System Right Burner System All units can be vented vertically Horizontal Run with Min.
  • Page 24: Mqrb5143 - Pre-Existing Enclosures Vs Framing Enclosure Around Fireplace

    MQRB5143 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 60-1/2” inside width. Opening should be greater than 53-1/2” minimum. Insert airbox on side of unit first and swing into place. Airbox Framing Enclosure Around Fireplace: If unit is in place before enclosure is built, minimum clearances for opening can be followed.
  • Page 25: Mqrb5143 -See Thru Framing

    MQRB5143 -See Through Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 26 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1”...
  • Page 27: Mqrb5143 Single Sided Framing

    MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 28 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1”...
  • Page 29: Mqrb5143 Combustible Enclosure Heights

    MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance.
  • Page 30: Mqrb5143 Surround Dimensions / Surround Clearances

    Surround Dimensions MQRB5143 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. • The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials. Surround Clearances MQRB5143...
  • Page 31: Mqrb5143 Facing Material Requirements

    MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surround, See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
  • Page 32: Mqrb5143 Mantel Clearances / Clearance To Combustibles

    MQRB5143 Mantel Clearances -Combustible Objects on Non- Combustible Mantel Warning- Combustible objects must not be placed Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and Non- on a Non-combustible Mantel unless the Combustible.
  • Page 33: Mqrb6961: Framing Your Gas Fireplace

    Framing Your Gas Fireplace MQRB6961: This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 34: Mqrb6961 Locating Your Appliance / Fireplace Dimensions

    MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit. MQRB6961 Fireplace Dimensions...
  • Page 35: Mqrb6961 - Pre-Existing Enclosures Vs Framing Enclosure Around Fireplace

    MQRB6961 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 78-1/2” inside width. Opening should be greater than 71-1/2” minimum. Insert airbox on side of unit first and swing into place. Airbox Framing Enclosure Around Fireplace: If unit is in place before enclosure is built, minimum clearances for opening can be followed.
  • Page 36: Mqrb6961 See Thru Framing

    MQRB6961 See Thru Framing MQRB6961SK Kit is required for a See Thru Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 37 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs 19-3/8” 20-3/8” Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be rotated to allow Min.1”...
  • Page 38: Mqrb6961 Single Sided Framing

    MQRB6961 Single Sided Framing An MQRB6961BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance).
  • Page 39 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1”...
  • Page 40: Mqrb6961 Combustible Enclosure Heights

    MQRB6961 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance.
  • Page 41: Mqrb6961 Surround Dimensions / Surround Clearances

    Surround Dimensions MQRB6961 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. • The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials. Surround Clearances MQRB6961...
  • Page 42: Mqrb6961 Facing Material Requirements

    MQRB6961 Facing Material Requirements These specifications are the same for all Models (6961N, 6961NE, 6961LP, 6961LPE). Note: If using Optional Surround, MQRB6961 See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
  • Page 43: Mqrb6961 Mantel Clearances / Clearance To Combustibles

    MQRB6961 Mantel Clearances -Combustible Objects on Non- Combustible Mantel Warning- Before installing any mantels it is important to determine the combustibility of its Combustible objects must not be placed material(s). There are two types of mantels to consider: Combustible and Non- on a Non-combustible Mantel unless the Combustible.
  • Page 44: Mqrb4436Bk / Mqrb5143Bk / Mqrb6961Bk Back Shield Kit -Single View

    MQRB44BK / MQRB51BK / MQRB69BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing” pages of this Manual). Warning : Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 45: Panel Installation

    Back Liner, False Fig.1 Bottom, and End Panel Installation: Remove Liner Clips from the inside of the Firebox (Fig.1). Place the Back Liner onto the firebox bottom with bends facing the rear firebox cover. Lift into place and set down on firebox ledge (See Fig.2).
  • Page 46: Mqrb4436 / Mqrb5143Sk / Mqrb6961Sk (See Thru Kit) Installation

    MQRB44SK / MQRB51SK / MQRB69SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: To cover the Side Fillers with non-combustible materials, they must be installed before Facing materials are applied. Warning : Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 47: Mqrb4436 / Mqrb5143 / Mqrb6961 Liner & False Bottom Installation

    MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation MQRB44PB1, MQRB51PB1, or MQRB69PB1-[1ea.] Porcelain False Bottom Single Sided: MQRB4436PLB, MQRB5143PLB, or MQRB6961PLB-[1ea.] Porcelain Back Liner Panel MQRB4436 (uses 5143PLE), MQRB5143PLE, or MQRB6961PLE-[2ea.] Porcelain End Panels Warning : Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 48: Mqrb4436 / Mqrb5143 / Mqrb6961 Liner & False Bottom Installation

    MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation See Thru: MQRB44PB2, MQRB51PB2, or MQRB69PB2-[1ea.] Porcelain False Bottom MQRB4436 (Uses 5143PLE), MQRB5143PLE or MQRB6961PLE-[2ea.] Porcelain End Panels False Bottom & End Panel Installation: 1. False Bottom Insert False Bottom into Fireplace.
  • Page 49: Mqrb4436, Mqrb5143 & Mqrb6961 Finishing Options

    MQRB4436, MQRB5143 & MQRB6961 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to give a continuous surface up to the opening of the fireplace door. Using Other Non-Combustible Materials as Side Fillers (Brick, Tile, Marble, etc.) Non-Combustible facing materials, such as brick or tile may be...
  • Page 50: Mqrb4436 / Mqrb5143 / Mqrb6961 Surround Installation

    MQRB4436 / MQRB5143 / MQRB6961 Surround Installation Surround Kits are available in 3 different finishes: MQRB4436 MQRB5143 MQRB6961 Small [1-1/2”] Large [4”] Small [1-1/2”] Large [4”] Small [1-1/2”] Large [4”] MQRB4419SBL MQRB4424SBL MQRB5019SBL MQRB5624SBL MQRB6919SBL MQRB6924SBL -Black MQRB4419SSS MQRB4424SSS MQRB5019SSS MQRB5624SSS MQRB6919SSS MQRB6924SSS...
  • Page 51: Fan Installation Mqrb4436 / Mqrb5143 / Mqrb6961

    Fan Installation MQRB4436 / MQRB5143 / MQRB6961 FAN KIT IS FOR USE IN BK (SINGLE SIDED) INSTALLATIONS ONLY Fan Kit should be installed before the fireplace is placed into wall cavity. To remove fan for service, the burner pan must be removed and work done through the opening (See Burner System Removal section).
  • Page 52: Fan Speed Control Outside Of Fireplace

    Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 53: Optional Glass Ember Installation

    MQRB4436 / MQRB5143 / MQRB6961 -Glass Ember Installation For best flame pattern it is essential to spread Crushed Glass or MQEMBER directly onto burner tube. Ensure the glass embers do not excessively overlap as this will affect the flame pattern. Part Number Description MQG5W...
  • Page 54: Optional Driftwood & Rock Installation

    Optional Driftwood & Rock Installation NOTE: Only Crushed Glass or MQ Embers can be placed directly on Burner Tube. Model Part Number Description MQRB4436, MQRB5143, MQRB6961 MQRBD1 Drift Wood (x4) and Rocks (x4) MQRB5143, MQRB6961 MQRBD2 Large 3pc Driftwood Set MQRB4436, MQRB5143, MQRB6961 MQRock2 30pc Rock Set- Contemporary Collection- Natural...
  • Page 55: Mq46D Driftwood / Rbcb1 Cannonballs

     MQ46D Driftwood Log Set- 3pcs. (Single Sided Units Only)  Place Log 1 on left side of fireplace against the back wall of the firebox.  Place Log 2 on the right side of fireplace against the back wall of the firebox and onto Log 1 as shown. ...
  • Page 56: Door And Glass Information

    Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass. It is therefore recommended that initially the glass be cleaned two or three times with a commercial fireplace glass cleaner.
  • Page 57: Door Latch Tool

    Infinite Series Door Latch Tool MQRB4436 / MQRB5143 / MQRB6961 A Door Latch Tool is provided to assist with removing and installing the glass doors on the Infinite Series. While it is not necessary to use this tool, it may prove helpful. Wait until unit is Completely cool before touching glass or attempting to remove door.
  • Page 58: Valve Access Cover Removal / Removable Lower Face Panel

    Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert fingers into holes in Access Panel and lift out. When replacing Access Panel, engage Tabs into Slots in Bracket. MQRB4436 / MQRB5143 / MQRB6961 Removable Lower Face Panel Installers Note: The Lower Face Panel on the valve side of the unit is shipped attached with only 3 screws for easy removal.
  • Page 59: Gas Line Installation / Gas Specifications

    1/2psig [3.5 kPa]. NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC. Since some municipalities have additional local codes, it is always best to consult your local authorities and the current CAN/CGA - B149.1 or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A...
  • Page 60: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 61: Troubleshooting The Millivolt Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 62: Burner System Maintenance

    Burner System Maintenance- MQRB4436 / MQRB5143 / MQRB6961 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 63: Gas Conversion For Top Convertible Pilot

    Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 64: Nova Mv Modulating Conversion Kit

    Gas Conversion for Modulator – PART C WARNING!- WARNING!-...
  • Page 65: Mqrb4436 Burner Section: Gas Conversion

    MQRB4436 Burner Section: Gas Conversion Models: MQRB4436N, MQRB4436LP, MQRB4436NE, MQRB4436LPE. Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Kit Number Brass (1000-255) 4436MQ-CKLP LP Conversion 1001-P167SI 1000-253closed Full 1001-P202SI -Millivolt- #30 (977.167) Open (0.907.202) 4436MQ-CKNG NG Conversion...
  • Page 66: Mqrb5143 Burner Section: Gas Conversion

    MQRB5143 Burner Section: Gas Conversion Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Kit Number Brass (1000-255) 5143MQ-CKLP LP Conversion 1001-P167SI 1000-253closed 3/8” 1001-P202SI -Millivolt- #30 (977.167) (0.907.202) 5143MQ-CKNG NG Conversion 1001-P165SI 1000-253closed 1/32”...
  • Page 67: Mqrb4436 / Mqrb5143 Burner Tube Removal / Burner System Removal/Installation Guide

    MQRB4436 / MQRB5143 Burner Tube Removal Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. Slide the Burner Tube away from the Plumbing Connection until it disengages from the orifice. Reverse these steps to reinstall. MQRB4436 / MQRB5143 Burner System Removal/Installation Guide Warning- Turn off Unit and allow to cool before cleaning.
  • Page 68: Mqrb4436 / 5143 / 6961 Moving Valve To Other Side Of Fireplace

    MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace Warning : Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. The Valve Assembly may be changed to the other side of the fireplace.
  • Page 69: Mqrb6961 Burner Section: Gas Conversion

    MQRB6961 Burner Section: Gas Conversion Models: MQRB6961N, MQRB6961LP, MQRB6961NE, MQRB6961LPE. Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Kit Number Brass (1000-255) 6961MQ-CKLP LP Conversion 1001-P167SI #49 x 2 1000-253closed Full Open 1001-P202SI -Millivolt- #30 (977.167) (0.907.202) 6961MQ-CKNG NG Conversion 1001-P165SI...
  • Page 70: Mqrb6961 Burner Tube Removal / Burner System Removal/Installation Guide

    MQRB6961 Burner Tube Removal Air Shutter Remove the six [8] DT screws from the lower portion of the Burner Tube Mount Brackets. Slide the Burner Tube away from the Plumbing Connection until it disengages from the orifices. Reverse these steps to reinstall. MQRB6961- Installer’s Note: If flames appear higher or lower at one end of the unit, the primary air can be adjusted on one of the two mixing sleeves to even the flame.
  • Page 71: Remote Receiver Location

    Remote Receiver Location For GT Series Remotes Only The Remote Receiver may be located inside of the unit- several inches to the left of the valve and near the front of the appliance. The Remote Receiver MUST be covered by the DCHS (Remote Control Heat Shield- see Parts List in manual).
  • Page 72: 51-Uhs For Infinite Series Mqrb4436, Mqrb5143, Mqrb6961

    NOTE: The gas line connection (See Each Section For Connections & Wiring) may be made of 1/2” rigid pipe or LAMP an Approved Z36 FAN TRANSFORMER Kingsman Flex ASSEMBLY Connector, such as FP15GC. Since some municipalities POWER have additional VENT...
  • Page 73: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that Cover provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 74: Remote Control Operation

    -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 75: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 76: Ipi Schematic Drawing #1: Basic Manual Hi / Lo - Manual On / Off

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 77: Ipi Schematic Drawing #2: Remote On / Off And Manual Hi / Lo

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 78: Egtm / Gtm System -No Batteries

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 79: Ipi Schematic Drawing #3: Remote On / Off, Variable Hi / Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 80: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 81: Lk2 Halogen Lamp Kit

    LK2 Halogen Lamp Kit MQRB4436 / MQRB5143 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. SYSTEM NOTES Each lamp is running on a dedicated circuit (Parallel circuit). This means that if one bulb fails the other will remain operational.
  • Page 82: Lk3 Halogen Lamp Kit

    LK3 Halogen Lamp Kit (MQRB6961) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. SYSTEM NOTES Each lamp is running on a dedicated circuit (Parallel circuit). This means that if one bulb fails the rest will remain operational.
  • Page 83: Venting

    Venting WARNING: WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD (SAFETY CAGE) SHALL BE INSTALLED. Notes: 1) Clearances are to the edge of the terminal plate. Add 6-3/4” for MQRB4436 & MQRB5143, and 8-1/8” for MQRB6961 to arrive at centerline.
  • Page 84: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z- Flex) venting kits and components specifically approved and LABELED for this stove may be used.
  • Page 85 Seal with High Temperature Mill Pac Sealant Figure 1 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps should be used to stabilize pipe. Expand inner and outer flex pipe to the point that the outer flex pipe protrudes approximately 2 to 3 inches past outer wall and the inner flex protrudes approximately 2 to 3 inches past the outer flex pipe.
  • Page 86: Horizontal Vent Table

    Minimum clearance to combustibles on venting is 1” with the following exceptions: MQRB4436 MQRB5143 MQRB6961 Top of horizontal 2” 2” 2” Top of 90 degree elbow in an enclosure under 72” 5” with Z57WTS 5” with Z57WTS Top of 90 degree elbow in an enclosure over 72” 4”...
  • Page 87: Venting Examples

    MQRB5143 Venting Examples All horizontal runs have a minimum ¼” rise per foot. 52-1/4" Wall Thimble and Roof Support The Wall Thimble is used in horizontal installations to shield the combustible material from the vent pipe. The appropriate size of thimble is required for each model. Please contact your local dealer for more information. Refer to Side Wall Venting for wall cutout information.
  • Page 88: Wall Thimble And Roof Support

    Installation of Side Wall Venting Note: Wall Thimble Shield [Z57WTS] must be used in Enclosures under 72” for MQRB4436 / MQRB5143, and under 78” for MQRB6961. 5” Min. for MQRB4436 / MQRB5143 6-1/2” Min. for 52-1/4”Min Vertical rise over 3ft horizontal run (MQRB5143 shown). Note that the minimum height from the bottom of fireplace to the centre of vent is 37-1/2"...
  • Page 89: Z57St24 / Z57St36 Horizontal Snorkel Terminations Mqrb4436 / Mqrb5143

    Z57ST24 / Z57ST36 Horizontal Snorkel Terminations MQRB4436 / MQRB5143 -FOR INFINITE SERIES II MODELS ONLY- Two snorkel terminations are available for MQRB4436 / MQRB5143 If a vertical rise is necessary on the exterior side of a building: Z57ST24 (24” Tall, 14-1/2” Center to Center) Z57ST36 (36”...
  • Page 90: Venting Straight Up Through Roof

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 91 2” Top of Horizontal Vent -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z710VT for MQRB6961 43ft Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting...
  • Page 92: Flue Restrictor Adjustment Mqrb4436 & Mqrb5143

    Flue Restrictor Adjustment MQRB4436 / MQRB5143 Only –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening. For vertically vented installations it is necessary to use the Flue Restrictor. Restrictor is set fully open from factory for short horizontal and vertical runs.
  • Page 93: Pvh58 Dimensions

    58PVH-Dimensions 12-1/2" 13" 1-1/2" 1/2" 10-5/8" 13" 10-5/8" 5" 11" 8-1/8" 1-1/4" 16" 13" 8-1/8" 5" 11" 11" 11-1/8" 11-3/8"...
  • Page 94: Pvh58 Installation Overview & Termination Installation

    PVH58 INSTALLATION OVERVIEW The PVH58 Horizontal Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Either Hard Pipe or Flex Pipe can be used, along with the appropriate adapter kit. The Following Steps Are Required To Install The PVH58 Horizontal Power Vent: ...
  • Page 95: Pvh58 Venting Clearances

    PVH58 VENTING CLEARANCES Note: Clearances are to the edge of terminal plate, add 5-1/2" to clearances to arrive at center line. Note: Local Codes or Regulations may require different clearances. A. Clearance above a veranda, porch, deck, or balcony or other combustible surface is 27”. Clearance above grade is12in [30cm] min.
  • Page 96: Pvh58 Venting Hard Pipe Or Flex

    PVH58 VENTING HARD PIPE OR FLEX Approved For 4/6-5/8”, 5/8” Hard Pipe The PVH-58 Power Vent is approved for use with DuraVent-DirectVent Pro Direct Vent system (Model DV-GS Series), and AmeriVent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp. Follow installation instructions provided by the appropriate manufacturer for installation of pipe, and adhere to the clearance to combustibles provided in this manual.
  • Page 97 Approved For 4/7”, 5/7” And 7/10” Kingsman Flex (Z-Flex) Pipe Flex Pipe Venting Kingsman Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths. Pipe can be expanded to twice their lengths e.g. 4ft. to 8ft. Fully expand pipe and cut off excess.
  • Page 98: Pvh58 Venting Configurations

    PVH58 VENTING CONFIGURATIONS Refer to Air Intake Adjustment PVH-58 section of this manual to adjust Air Maximum / Minimum Vent Lengths: Intake Shutter. Maximum Vent Length is 125 ft plus six 90° elbows with Air Intake Shutter fully closed. Termination must not be below unit. This power vent can be installed up to 3ft below the installed fireplace on runs less than 100ft and not more than four 90°...
  • Page 99: Pvh58 Wall Thimble Installation & Power Vent Mounting

    PVH58 WALL THIMBLE INSTALLATION An 11 inch square opening is required. Center Wall Thimble over the 11 inch square opening and secure both pieces on either sides of the wall. Ensure that cutout is at the lower right corner, as electrical conduit must pass through this area. Cutout At Lower Telescopic Wall Thimble Right Corner when...
  • Page 100: Pvh58 Wiring Harness Connections

    PVH58 Wiring Harness Connections WARNING WARNING WARNING Electrical Grounding Instructions – A qualified electrician must connect This appliance is equipped with a Label all wires prior to disconnection electrical wiring to junction outlet for three – pronged (grounding) plug for when servicing controls.
  • Page 101: Pvh58 Millivolt System Connections

    PVH58 Millivolt System Connections GREEN/GRND 10ft Double Pole Switch Wiring Harness for Millivolt Systems. Connects to Double Pole Switch as Shown. A 20ft extension BLACK BROWN harness can be ordered. See Wiring Harness Connections WHITE section for installation of extension harness. Route Switch Wiring Harness DOUBLE POLE...
  • Page 102 Connect to TH and TH / TP Tabs on Valve Connect to Power Vent Cable Connect to Double Pole Switch Cable Plug into120v AC Outlet MILLIVOLT POWER VENT CONTROL MODULE FIREPLACE IS SUPPLIED WITH ONE JUNCTION BOX. ADDITIONAL OUTLETS DOUBLE POLE SWITCH MAY BE REQUIRED.
  • Page 103: Pvcm Schematic - Millivolt

    PVCM Schematic - Millivolt...
  • Page 104: Pvh58 Ipi System Connections

    PVH58 IPI SYSTEM CONNECTIONS Mount Power Vent Control Module In Fireplace. Reposition Lamp Transformer Power Vent Control Module Mounted Lamp Transformer housing may housing. Install Power Vent Control inside fireplace (TOP VIEW). need to be moved toward valve. Module as shown. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 105: Pvh58 Basic Ipi System Connections

    PVH58 Basic IPI System Connections RECOMMENDED METHOD OF CONNECTION: First ensure the entire IPI system is working properly without connecting any Power Vent components. Then connect the Power Vent Control Module.  PV1A – Valve  PV1B – Orange Wire on 912 Harness ...
  • Page 106: Pvh58 All Ipi System Connections

    PVH58 All IPI System Connections RECOMMENDED METHOD OF CONNECTION: First ensure the entire IPI system is working properly without connecting any Power Vent components. Then connect the Power Vent Control Module.  PV1A – Valve  PV1B – Orange Wire on 912 Harness ...
  • Page 107: Pvcm Schematic - Ipi

    PVCM Schematic - IPI...
  • Page 109: Pvh58 Air Intake Adjustment

    PVH58 Air Intake Adjustment The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace. Longer runs require more draw, while shorter runs require less. If flame pattern is slow and lazy, and sooting is occurring, more draw is required. If flame pattern is running too fast, less draw is required.
  • Page 110: Pvh58 Troubleshooting

    PVH58 Troubleshooting NOTE: Before connecting Power Vent Control Module, ensure that all other systems and accessories (Remote Control, Fan, Lights, etc.) are connected and working properly. !WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. BEFORE TROUBLESHOOTING THE GAS CONTROL SYSTEM, BE SURE EXTERNAL GAS SHUT OFF IS IN THE "ON" POSITION.
  • Page 111: Pvh58 Parts List

    PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQRB4436 AND MQRB5143 VENTING AND VENTING ADAPTERS For fireplaces to be converted to hard pipe (DuraVent-DirectVent Pro, etc.) at the fireplace: Z57DFA Hard Pipe Adapter (Adapts MQRB4436 & MQRB5143 to accept Hard Pipe at Fireplace) For Power Vent installations where flex pipe will be used up to the Power Vent unit: Z57PVA* Pipe Reducer 8”Sm –...
  • Page 112 58PVH-P3211 3/4” K.O. Bushing 58PVH-WTA Wall Thimble Assembly PVH20H Main Wiring Harness Assembly – Extension Harness (20ft) PVC58MV Power Vent Control Module – Millivolt Box 58PVH-P124 Double Pole Switch 58PVH-P421 Timer Switch PVC58IPI Power Vent Control Module – IPI Box 58PVH-P421 Timer Switch 58PVH-P156...
  • Page 113: Mqrb4436 -Parts List

    4436MQ-BNGSI Burner Assembly-Natural Gas c/w Valve MQRB44BK Back Shield Kit - (Single View) Shield and System (MQRB4436N) Cover, False Bottom with Series II Pilot Shield 4436MQ-BLPSIE Burner Assembly- Propane c/w Valve ,False Bottom Cover, Series II Pilot Bracket, System (MQRB4436LPE)
  • Page 114 Center to Center) Z57ST36 Horizontal Snorkel Termination (36” Tall, 26-1/2” Center to Center) Z57STSC Safety Cage for Horizontal Snorkel Termination Kingsman Flex venting MUST be used on the MQRB4436. Use of DuraVent-DirectVent Pro or other hard pipe Venting systems is not permitted.
  • Page 115: Mqrb5143 -Parts List

    MQRB5143 Parts List MQROCK2 Rock Set - Contemporary Collection - Natural Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide MQROCK3 Rock Set - Contemporary Collection - Multi- Listed for USA/Canada as a Decorative Appliance: Linear LH Colored Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and MQG5W Decorative Ember Glass - White - 5 lbs BTU Adjustment, Ceramic Glass, 5/7"...
  • Page 116 ZDVSS Siding Shield - Heat Deflector for FDVHT Round Termination ZDVSSLR Siding Shield - Large Return - for FDVHSQ or FDVHT ZDV48GP Galvanized Pipe 7" Dia. x 48" (Vertical Installations) ZDVAAF Flashing 7" c/w Storm Collar (1/12 to7/12) ZDVAF2 Flashing 7" c/w Storm Collar (8/12 to 12/12) ZDVAF3 Flashing 7"...
  • Page 117: Mqrb6961 -Parts List

    MQRB6961 Parts List MQ Stone Decorative Stones Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -69” Wide MQRBD2 Drift Wood and Rocks Listed for USA/Canada as a Decorative Appliance: Linear LH MQROCK2 Rock Set - Contemporary Collection - Natural Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and BTU Adjustment, Ceramic Glass, 7/10"...
  • Page 118 Z710GP48 Galvanized Pipe 10” Dia. X 4ft (Vertical Installation) Z710FS Firestop Spacer for 10” Pipe Z710RS Roof Support for 10” Pipe Z710FK5 Flex Kit [7/10”x5’ Expanded: Springs, Screws, Millpac] Z710FK8 Flex Kit [7/10”x8’ Expanded: Springs, Screws, Millpac] Z710FK20 Flex Kit [7/10”x20’ Exp.: Springs, Screws, Millpac] ZDV7FC Flex Connector 7”...
  • Page 119: Common Parts For Mqrb4436, Mqrb5143 And Mqrb6961

    Common Parts for MQRB4436, MQRB5143 and MQRB6961 Accessories 1001-P167SI Orifice Pilot LP977.167TC SIT 1001-P633SI Valve Nova LP Hi/Lo 0820651 Z1MT Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) Millivolt 1001-P634SI Valve Nova NG Hi/Lo 0820652 Wall Mount 1001-P713SI Pilot Burner LP 199.713TC SIT 3927ZDV-...
  • Page 120 1002-P013si Stepper Motor (NG) 1002-P012si Stepper Motor (LP) 1002-P016si Hi/Lo Regulator (NG) 1002-P014si Hi/Lo Regulator (LP) Miscellaneous Parts 1000-150GE Silicone GE Red IS806 #736 1000-150MP Hi Temp Millpac Sealant 840099 1000-214 Piezo Igniter 1244-17 MARK 21 1000-215 Pal Nut (18MMXI.5MM) BLK (1364.03) 1000-218 Switch Ivory (1451/001) 1000-227...
  • Page 121: Glass Safety / Termination Cap Safety -All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 122: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.