Table of Contents

Advertisement

Quick Links

Model Numbers:
ZCVRB60N, ZCVRB60NE, ZCVRB60LP, ZCVRB60LPE
MQZCVRB60NE2, MQZCVRB60LPE2
Certified to:
ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters • CSA 2.17-2017
Installation Instructions
SERENE
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
VENTED GAS FIREPLACE HEATER:
NOT FOR USE WITH SOLID FUEL.
WARNING:
DO NOT OPERATE THIS APPLIANCE WITHOUT
DECORATIVE GLASS EMBERS ON BURNER AND
MEDIA TRAY
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or
mobile home, where not prohibited by
This appliance is only for use with
the type of gas indicated on the
rating plate. This appliance is not
convertible for use with other
gases, unless a certified kit is
C#400720
local codes.
used.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada February 28, 2020
Part# 60ZCV-MAN17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZCVRB60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman ZCVRB60

  • Page 1 Installation Instructions C#400720 Model Numbers: ZCVRB60N, ZCVRB60NE, ZCVRB60LP, ZCVRB60LPE MQZCVRB60NE2, MQZCVRB60LPE2 Certified to: ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters • CSA 2.17-2017 SERENE INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. VENTED GAS FIREPLACE HEATER: NOT FOR USE WITH SOLID FUEL.
  • Page 2: Table Of Contents

    Vented Chase – Style 1 – Opening With No Grill..................... 20-21 Vented Chase – Style 2 – Opening With Grill....................22-23 Vented Chase -Style 2 – Opening With Grill - Kingsman VL60EG..............VL60EG Grill Installation........................... VL60EGS Side Grill Installation........................Framing Dimensions –Vented Chase -Ventilation Plates Removed..............
  • Page 3 ULK64 Universal Light Kit (Optional Accent Lighting Kit)................. 49-50 LED Lighting..............................LED Light Strip Replacement........................... RBCB1 -Cannonballs- Installation Instructions....................MQ Dealer Accessories for ZCVRB60......................54-55 MQRBD3 5-Piece Driftwood Log Set……………………………………………………………………....PROFLAME 1 IPI SYSTEM IPI Electronic Ignition System........................... Remote Control Operation..........................
  • Page 4: Safety Screen Installation / Removal

    60ZCVCSS Safety Screen Installation / Removal ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screen. Engage slots in top of Screen Mount Brackets onto screw in fireplace opening and push bottom in.
  • Page 5: Pre-Installation Questions And Answers / Operating Instructions

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 6: Warnings, Installations, And Operations

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States.
  • Page 7 Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Framing Your Gas Fireplace

    ZCVRB60 Framing Your Gas Fireplace 4. A Hearth is not required for this unit. This section is intended for qualified installers only. Before beginning, make note of where the gas and Vertical Venting in Cold Climates electrical accesses are located on the unit. This will In cold climate conditions where temperatures go below streamline the construction process.
  • Page 10: Nailing Tab Guide

    ZCVRB60 Nailing Tab Guide [Qty] 2 Nailing Tabs are located on each side of the fireplace front frame. These Nailing Tabs can be used in two ways: 1/2” Drywall Flush with Face of Fireplace Framing Flush with Face of Fireplace Fireplace and Combustible Wall to be covered with a Fireplace to be covered with Non-Combustibles (e.g.
  • Page 11: Zcvrb60 -Facing Requirements- Units With Unvented Chase (As Shipped)

    ZCVRB60 -Facing Requirements- Units With Unvented Chase (as Shipped) Finishing Recommendations (Obtained from professional NOTE: ANY MATERIALS COVERING THE FACE OF THE construction contractors and finishers): FIREPLACE BESIDE AND ABOVE THE FIREPLACE OPENING MUST BE NON-COMBUSTIBLE (i.e. brick,  Frame unit with metal studs (minimum 20 gauge).Wooden stone, tile, concrete board).
  • Page 12: Tile Lip Kit- V60Ptlk

    V60PTLK ZCVRB60 Tile Lip Kit ZCVRB60 Tile Lip Kit (V60PTLK): -1 Bottom Piece -2 Sides - [Qty] 11 Pan Head DT Screws SIDE VIEW Side Side Bottom 5/8”...
  • Page 13: Fireplace Installations In Covered Outdoor Locations

    Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed. Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement. However, all installation clearances in the appliance manual must be observed. Framing, Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc.
  • Page 14: Locating Your Appliance / Fireplace Dimensions

    ZCVRB60 Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is...
  • Page 15: Zcvrb60 -Unvented Chase Vs Vented Chase- Choose Your Installation

    ZCVRB60 –Unvented Chase VS Vented Chase- Choose Your Installation Look at the following chart before you begin the installation. Wall Surface Mantel Height TV above Fireplace Heat can be Lowest Temperature with Recessed directed to (From Bottom of Enclosure above front of...
  • Page 16: Framing Dimensions -Unvented Chase- Ventilation Plates In Place -As Shipped

    ZCVRB60- Framing Dimensions –Unvented Chase-Ventilation Plates In Place- As Shipped Determine whether face of fireplace will be:  Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).  Flush with framing (to be covered with concrete board for a Flat Wall appearance).
  • Page 17: Mantel Clearances - Unvented Chase - Ventilation Plates In Place -As Shipped

    ZCVRB60 -Mantel Clearances –Unvented Chase- Ventilation Plates In Place -As Shipped Before installing any mantels it is important to determine the combustibility of its material(s). There Mantel Dimensions are from front 76” are two types of mantels to consider: face or Non-Combustible Facing Minimum Combustible and Non-Combustible.
  • Page 18: Clearance To Combustibles - Unvented Chase -Ventilation Plates In Place -As Shipped

    ZCVRB60 -Clearance to Combustibles –Unvented Chase- Ventilation Plates In Place – As Shipped Clearance to Combustibles ZCVRB60 Unvented Chase Front 36” [92cm] Back (from Stand-offs) 0” [0cm] Side (from Stand-offs) 0” [0cm] Floor 0” [0cm] Minimum Ceiling Height (from bottom of fireplace) 76”...
  • Page 19: Vented Chase -Removal Of Ventilation Plates

    Kingsman Enclosure Grills – Serene Series Fireplaces – ZCVRB47 & ZCVRB60 Serene Series Units are designed to work with specific Kingsman Enclosure Grills when installed into a Vented Chase: ZCVRB47 works with the V46EG Enclosure Grill or VL60EGS Enclosure Grills.
  • Page 20: Vented Chase - Style 1 - Opening With No Grill

    ZCVRB60 – Vented Chase – Style 1 – OPENING WITH NO GRILL ⚠ NOTE:  VENTILATION PLATES MUST BE HEAT CANNOT BE DISCHARGED INTO THE WALLS, FLOOR, OR REMOVED. CEILING. Heat must exit through the required vented chase opening near ...
  • Page 21 ZCVRB60 –Vented Chase- Style 1 – OPENING WITH NO GRILL VENTILATION PLATES MUST BE REMOVED Ceiling / Enclosure Top Open Area 200 Sq. In. MIN Open Area ⚠ NOTE: Minimum Opening is 200 SQ. IN. MINIMUM 200sq. inches of free air.
  • Page 22: Vented Chase - Style 2 - Opening With Grill

    ZCVRB60 – Vented Chase – Style 2 – OPENING WITH GRILL ⚠ NOTE: HEAT CANNOT BE DISCHARGED INTO THE  VENTILATION PLATES MUST BE REMOVED. WALLS, FLOOR, OR CEILING. Heat must exit through the  Grill openings must be within 3/4” of enclosure top.
  • Page 23 ZCVRB60 – Vented Chase – Style 2 – OPENING WITH GRILL VENTILATION PLATES MUST BE REMOVED Grill Opening must be within 3/4” of Enclosure Top FRAMING TO CEILING- MINIMUM ENCLOSURE- GRILLS AT FRONT AND BACK FRAMING TO CEILING - Each grill must be 220...
  • Page 24: Vented Chase -Style 2 - Opening With Grill - Kingsman Vl60Eg

    ZCVRB60 –Vented Chase -Style 2 – OPENING WITH GRILL - Kingsman VL60EG VENTILATION PLATES MUST BE REMOVED. 3/4” MAX Enclosure Top Sealed Enclosure Top to Grill Opening ⚠ NOTE: If using insulation in vented chase (i.e. for outside wall), wall 3-5/8"...
  • Page 25: Vl60Eg Grill Installation

    VL60EG Grill Installation- -Option- Compatible with Vented Chase *This Grill Meets Minimum Opening Air Free Requirements* Parts List: This Kit comes with two installation options: [1] Louver Grill (ready to paint) Outer Trim Grill Mount - For a Quick and simple installation. [1] Outer Trim Grill Mount (ready to paint) Hidden Grill Mount - For a very clean installation with only the grill [1] Upper Frame for Hidden Grill Mount...
  • Page 26: Vl60Egs Side Grill Installation

    VL60EGS Side Grill Installation ZCVRB60 Option Contents of Kit: [Qty 2] Side Grill assemblies (ready to paint). 15-1/4” x 6-5/8” Tall opening required. Fits into 6-5/8” Opening Pressure Fit into 15-1/4” Opening Pressure Point ⚠ Grill openings must be within 3/4” of enclosure top.
  • Page 27: Framing Dimensions -Vented Chase -Ventilation Plates Removed

    ZCVRB60 -Framing Dimensions –Vented Chase -Ventilation Plates Removed Determine whether face of fireplace will be: HEAT CANNOT BE DISCHARGED INTO THE WALLS, FLOOR, OR CEILING. Heat must exit through the  Flush with finished wall (e.g., for surround, cultured stone or other required vented chase opening near the ceiling.
  • Page 28: Optional Recessed Cavity Dimensions

    ZCVRB60 – Vented Chase - Optional Recessed Cavity Dimensions  Recessed Cavity may begin immediately above top header (i.e. 4” for 2 x 4 with drywall).  Television should be minimum 1” away from opening of Vented Chase. 76” Minimum ceiling height from bottom of fireplace Maximum 3/4”...
  • Page 29: Mantel Clearances -Vented Chase -Ventilation Plates Removed

    ZCVRB60 -Mantel Clearances –Vented Chase -Ventilation Plates Removed Before installing any mantels it is important to determine the combustibility of its material(s). There 3/4” MAX from top are two types of mantels to consider: of Enclosure Combustible and Non-Combustible. A Combustible Mantel is one that...
  • Page 30: Clearance To Combustibles -Vented Chase -Ventilation Plates Removed

    ZCVRB60 -Clearance to Combustibles –Vented Chase -Ventilation Plates Removed- Clearance to Combustibles ZCVRB60 Vented Chase Front 36” [92cm] Back (from Stand-offs) 0” [0cm] Side (from Stand-offs) 0” [0cm] Floor 0” [0cm] Minimum Ceiling Height (from bottom of fireplace) 76” [193cm] Top (from Stand-offs) 0”...
  • Page 31: Surround Dimensions / Clearances

    Gap between surround and face of fireplace is determined by which mount-hole is used. ZCVRB60 Surround Clearances NOTE: In order to install the Surround, No Finishing Materials are allowed within a 1/2” area at the Top & Bottom, and a 1/8” area on the Sides of the Fireplace Opening.
  • Page 32: Surround Installation

    ZCVRB60 Surround Installation Surrounds: ZCVRB60S1BL (Black), ZCVRB60S1SS (Stainless Steel) Dimensions: (64”W x 23”H) Each kit contains: (Qty-1) Surround Frame Surround Frames are 3/4” thick, by 1-1/2” wide.   Gap between surround and face of fireplace is variable- 5/8”, 7/8”, or 1-1/8”- determined by which mount hole is used.
  • Page 33: Uhs Box

    ZCVRB60 Component Locations Millivolt and Proflame 1 Units: UHS Box ULK64 Junction Box Valve Transformer Location (All Models) IPI Module Battery Backup or Battery Backup Remote Receiver Fan Control Module Proflame 2 Units: Z46FK2 FAN Proflame 2 Box Valve LED Module...
  • Page 34: Fan Kit Installation

    ZCVRB60 Z46FK Fan Kit Installation Fan Kit should be installed before facing material is applied or surround is installed. To remove fan for service, the burner pan must be removed and work done through the opening (See Burner System Removal section).
  • Page 35: Split Receptacle- Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 36: Door And Glass Information

    ZCVRB60 Door and Glass Information Glass Cleaning Removal of the Glass Door ZCVRB60 It will be necessary to clean the glass periodically. During start- up, condensation, which is normal, forms on the inside of the glass and causes dust, lint etc. to cling to the glass surface. Also, Remove the door by unlatching the 2 top latches.
  • Page 37: Valve Access Cover Removal / Removable Lower Face Panel

    ZCVRB60 Valve Access Cover Removal Remove the Safety Screen in order to access igniter and valve controls. Refer to Safety Screen Installation / Removal instructions. Safety Screen ZCVRB60 Removable Lower Face Panel Installers Note: The Lower Face Panel is removable. This allows all necessary gas line and electrical connections to be made easily.
  • Page 38: Zcvrb60Pl Liner Installation

    ZCVRB60PL Porcelain Liner Installation ZCVRB60PRL Parts List: [1] – Back Liner Center Clip [1] – Left Side Liner Media Fence [1] – Right Side Liner Pilot LEFT RIGHT REMOVE ALL 6 BRICK CLIPS PLUS CENTER CLIP & DISCARD Center Clip BACK REMOVE MEDIA FENCE- DO NOT DISCARD...
  • Page 39 REPLACE MEDIA FENCE IN THE INSTALL SIDE LINERS ORIGINAL POSITION SIDE LINER BACK LINER Screw Screw Air Slot Air Slot BACK SIDE LINER LINER Media Fence Media Fence Screw Screw SIDE BACK LINER LINER NOTE: For some Media Fence units, the Rear Mount Slot of the Side Liners may be aligned with a 1/4”...
  • Page 40: Mqvrb60Rls Liner Installation

    MQRB60RLS Stacked Brick Liner Installation MQRB60RLS Parts List: [1] – Back Liner Center Clip [1] – Left Side Liner [1] – Right Side Liner Media Fence Pilot LEFT RIGHT SIDE SIDE PANEL PANEL REMOVE ALL 6 BRICK CLIPS PLUS CENTER CLIP DO NOT DISCARD BACK LINER Center Clip...
  • Page 41: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 42: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When Immediately call your gas supplier from a neighbour’s phone.
  • Page 43: Annual Inspection List For Determining Safe Operation Of A Direct Vent Gas Fireplace

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 44: Burner System Maintenance

    ZCVRB60 Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. ⚠ -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 45: Gas Conversion Part A

    ZCVRB60 Gas Conversion Part A Models: ZCVRB60N, ZCVRB60NE, ZCVRB60LP, ZCVRB60LPE, MQZCVRB60NE2, MQZCVRB60LPE2 Kit Number Description Pilot Orifice Burner Orifice Brass Nipple Hi/Lo Shutter Regulator Brass (1000-255) 60ZCVRB-CKLP Propane Conversion 1001-P167SI 1000-P201VE 1/4” 1001-P202SI -Millivolt- #30 (977.167) (0.907.202) 60ZCVRB-CKNG NG Conversion...
  • Page 46: Gas Conversion Kit For Top Convertible Pilot Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 47: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 48: Burner System Removal/Installation Guide

    ZCVRB60 Burner System Removal/Installation Guide WARNING: Turn off Unit and allow to cool before cleaning. Only a Qualified service technician should service and repair this appliance. Air Access Plate Pilot Shield #47ZCVRB-258-2 Inner Cover Plate False Bottom / Media Tray...
  • Page 49: Ulk64 Universal Light Kit (Optional Accent Lighting Kit)

    ZCVRB60 ULK64 Universal Light Kit ( Optional Accent Lighting Kit) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Contents of Kit:  [4] 12V Halogen Lamps  Lamp Plate with Insulated Studs & wiring ...
  • Page 50 Screw Screw Screw Screw STEP 4: Place Lamps in position in firebox. Attach to fireplace with a single screw at the locations shown above for each unit. Replace burner tube and false bottom, along with pilot shield. Remove Tab Remove Tab STEP 5: Flip False Bottom upside down.
  • Page 51: Led Lighting

    MQZCVRB60 LED Lighting Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. LED LIGHT STRIP 584-X10 HARNESS YELLOW CONNECTOR GROUNDING STUD PROFLAME 2 MODULE LED CONTROLLER MODULE BATTERY BACKUP MQZCVRB60 –...
  • Page 52: Led Light Strip Replacement

    TECHNICAL BULLETIN MODEL MQRB47 / MQRB60 60VL-LED48 PARTS DATE February 26, 2020 1x LED Light Strip SUBJECT LED LIGHT STRIP INOPERABLE. 2x Zip Tie RESOLUTION Replace LED light strip. TOOLS CAUTION ⚠ Recommended Wear Safety Glasses and Work Gloves This installation requires a Phillips-head Driver, Needle- To reduce possibility of injury, wear safety glasses and nose plier, and Side-cutter.
  • Page 53: Rbcb1 -Cannonballs- Installation Instructions

    RBCB1 -Cannonballs- Installation Instructions Assorted size and colors. Place randomly as desired inside fireplace. Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur. ...
  • Page 54: Mq Dealer Accessories For Zcvrb60

    ZCVRB60 MQ Dealer Accessories The following Accessories are available through MQ Dealers only. CRUSHED GLASS MEDIA ACCESSORY ITEM DESCRIPTION Spread the glass embers onto the false bottom and burner. MQG5C Ensure the glass embers do not excessively overlap as this will affect Decorative Ember Glass –Bronze...
  • Page 55 MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom.  MQRock2 MQRock3 MQRBD1 NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur.  Do Not Cover any part of the burner tube with logs as sooting may occur. ...
  • Page 56: Mqrbd3 5-Piece Driftwood Log Set

    MQRBD3 -5 Piece Driftwood Log Set- OPTION Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. ⚠ NOTE LOG 1  For best flame pattern it LOG 3 is essential to spread supplied Crushed Glass or MQEMBER directly LOG 4...
  • Page 57: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview Cover The IPI system is an advanced burner controller that provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 58: Remote Control Operation

    Proflame 1 -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart *thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room *thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room *thermostat.
  • Page 59: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 60: Configuration #1: Basic System

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 61: Configuration #2: Remote On/Off

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 62: Egtm / Gtm System -No Batteries

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 63: Configuration #3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 64: Ipi Lighting Instructions

    - Lighting Instructions - Intermittent Pilot Ignition System (IPI) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed.
  • Page 65: Proflame 2 Parts List

    Proflame 2 –NE2 / LPE2 -IPI System Parts List- IPI PROFLAME 2 - COMPONENT PARTS IPI - PF1 and PF2 Common Components PART NO. DESCRIPTION PART NO. DESCRIPTION 1005-P001SI Valve IPI Proflame PF2 885.001 NG - Stepper 12. 1002-P033SI TC - Pilot Burner IPI (Assembled) NG 199.033 1005-P002SI Valve IPI Proflame PF2 885.002 LP - Stepper 13.
  • Page 66: Proflame 2 Ifc Module And Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button  Within 10 seconds press the button again until Pairing Remote Control: you hear it beep. ...
  • Page 67: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a flame. The CPI (Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather. When the firebox and exhaust vent are warm, exhaust gasses will readily flow out of the firebox.
  • Page 68: Remote Flame Control, Room Thermostat

    Proflame 2 Remote Control...
  • Page 69: Smart Thermostat, Fan Speed Control, Remote Dimmer Control

    Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 71: Vent Terminal Clearances

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 72: General Vent Installation Information

    FLEX PIPE VENTING Kingsman Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths. Pipe can be expanded to twice their lengths e.g. 4ft to 8ft. Fully expand pipe and cut off excess. Do not use more than 2 couplers (Order ZDV5FC & ZDV8FC – DO NOT fabricate couplers) to extend short pipes.
  • Page 73: Venting Routes And Components

    Venting Routes And Components Venting Routes and Components How to Use the Horizontal Vent Table Since it is very important that the vent system maintain its 1. Determine the height of the system and the number of balance between the combustion air intake and the flue gas bends required.
  • Page 74: Venting Straight Up Through Roof

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 75 -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z58VT Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re- circulation of exhaust products. For additional requirements check local codes.) 24” 18” MIN Clearance above highest point of exit on roof 18 inches (45cm) 43ft...
  • Page 76: Air Intake Adjustment Plate - Vertical Venting And Power Venting

    ZCVRB60 Air Intake Adjustment Plate - Vertical Venting and Power Venting Must be Adjusted Before any Medium Base is added. The Air Intake Adjustment Plate must be set at the correct position for the fireplace to function properly. Location- The Air Intake Adjustment Plate is...
  • Page 77: Glass Safety / Termination Cap Safety

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 78: Approved For Power Vent Pvh58 / Pvh58Fm

    Approved for Power Vent PVH58 / PVH58FM - This appliance is approved for use with Kingsman Horizontal Power Vents - A Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible.  NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 79: Pvh58 Parts List

    Power Vent Parts List – 5/8 Venting NUMBER DESCRIPTION PVH58 Horizontal Power Vent Starter Kit ‐ Exterior Mount PVH58FM Horizontal Power Vent Kit ‐ Flush Mount Note: Must use a one foot section of 5/8 DV hard pipe to connect to the Power Vent Termination (not supplied) CHOOSE CONTROL MODULE OR HARNESS DEPENDENT ON VALVE SYSTEM PVC58MV Power Vent Control Module ‐...
  • Page 80: Parts Lists

    Grill ‐ Side (Pair) for Enclosure ‐ Unfinished System (ZCVRB60NE) (16 3/16" x 7 1/4") Conversion Kits Optional Wall Surrounds 60ZCVRB-CKLP LP Conversion Kit for ZCVRB60 Millivolt ZCVRB60S1BL Surround Trim Kit ‐1 1/2" Wide ‐ 60ZCVRB-CKNG NG Conversion Kit for ZCVRB60 Black (Covers 64"W x 23"H)
  • Page 81 1000-085 Remote Control IPI PF1‐ EGTMRCP FP15GC Stainless Steel Gas Connector Thermostat/Modulating ‐ LP Remote Control IPI PF1‐ EGTFRCN Kingsman Fireplace Venting Thermostat/Modulating/Fan ‐ NG Z58VT Vertical Vent Termination Remote Control IPI PF1 ‐ EGTFRCP Z58HT Horizontal Vent Termination Thermostat/Modulating/Fan ‐ LP...
  • Page 82: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System ⚠ WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is...
  • Page 83: Limited Lifetime Warranty

    During the first year after installation of the appliance, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents