Kingsman MQVL48NE2 Installation Instructions Manual

Hide thumbs Also See for MQVL48NE2:
Table of Contents

Advertisement

Quick Links

Model Numbers: Single Side Units:
MQVL48N, MQVL48NE, MQVL48NE2, MQVL48LP, MQVL48LPE, MQVL48LPE2
Bay Peninsula Units:
MQVLBG48N, MQVLBG48NE, MQVLBG48NE2, MQVLBG48LP, MQVLBG48LPE, MQVLBG48LPE2
Certified to: ANSI Z21.88-2017/CSA 2.33-2017 and CSA2.17-2017
VENTED GAS FIREPLACE HEATER
- Certified for use with Adjustable Vented Platform (AVP), and Heat Distribution System (HDS) -
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Leave the building immediately.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
 If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use
with other gases, unless a certified kit is used.
VENTED GAS FIREPLACE HEATER:
NOT FOR USE WITH SOLID FUEL
- Installation Instructions -
WARNING: DO NOT OPERATE THIS APPLIANCE WITHOUT
DECORATIVE GLASS EMBERS ON BURNER AND MEDIA TRAY
ENCLAVE
CONSUMER: Retain this manual for future reference.
Printed in Canada December 9, 2019 Part# 48MQVLBG-MAN17
A Division of R-Co. Inc. 2340 Logan Ave.
Winnipeg, Manitoba Canada R2R 2V3 Ph.: (204) 632-1962

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MQVL48NE2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingsman MQVL48NE2

  • Page 1: Cover

    - Installation Instructions - Model Numbers: Single Side Units: MQVL48N, MQVL48NE, MQVL48NE2, MQVL48LP, MQVL48LPE, MQVL48LPE2 Bay Peninsula Units: MQVLBG48N, MQVLBG48NE, MQVLBG48NE2, MQVLBG48LP, MQVLBG48LPE, MQVLBG48LPE2 Certified to: ANSI Z21.88-2017/CSA 2.33-2017 and CSA2.17-2017 VENTED GAS FIREPLACE HEATER ENCLAVE - Certified for use with Adjustable Vented Platform (AVP), and Heat Distribution System (HDS) - ⚠...
  • Page 2: Warnings

    IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE.  If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.  Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the...
  • Page 3 Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States.
  • Page 4: Table Of Contents

    MQVL48 / MQVLBG48 Table of Contents Cover..................................Warnings................................. Table of Contents..............................Installation Requirements for the Commonwealth of Massachusetts..............Carbon Monoxide (CO) Detector..........................Pre-installation Questions and Answers......................... Operations and Maintenance Instructions......................Mobile Home/Manufactured Housing Installation....................Fireplace Installations in Covered Outdoor Locations.................... INSTALLATION &...
  • Page 5 MQRBD3 5 Piece Driftwood Log Set........................MQLOGF48D - 6 Pc. Driftwood Log Set......................... MQRBBW – 5 Pc. Birchwood Log Set........................Burner System Gas Line Installation / Gas Specifications Chart..................... Millivolt System, Lighting, and Burner Control......................Annual Inspection List............................. Troubleshooting the Gas Control System....................... Burner System Maintenance...........................
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 7: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Fireplace Installations In Covered Outdoor Locations

    Intertek safety certification will not apply to this installation method. This installation method must be deemed acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed. Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement.
  • Page 10: Framing Your Gas Fireplace

    Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 11: Vented Chase Requirements

    Vent can be added 2” MAX from top of Chase 2” MAX from top of Chase Min 151 Sq. In. Must be in the Uses Kingsman Uses Kingsman same Pressure VL48EG Grill VL48EG Grill Zone (Room / Area) Minimum 151 Sq.
  • Page 12: Vl48Avp Adjustable Vented Platform

    VL48AVP Adjustable Vented Platform -OPTION The Adjustable Vented Platform is an optional installation base. Height is variable from approximately 14-3/4” to 27-1/4”. Venting slots are provided at the bottom and between the fireplace and the platform. INNER 9-3/4” SIDE 27-5/16” PANEL 14-13/16 14-13/16”...
  • Page 13 STEP TWO: ASSEMBLE TOP REAR BRACE INNER SIDE INNER PANEL INNER SIDE SIDE PANEL PANEL OUTER OUTER SIDE FRONT OUTER PANEL PANEL FRONT PANEL TILE LIP TILE LIP 2. Assemble Top using supplied screws. INNER SIDE PANEL INNER INNER SIDE SIDE PANEL PANEL...
  • Page 14: Mqvl48 / Mqvlbg48 Framing - Platform Base

    MQVL48 / MQVLBG48 Framing – Platform Base A Platform Base has air opening requirements that must be met. Top of Platform Must Have Minimum 480 Square Inches Free Air Opening ⚠ DO NOT COVER TOP OF PLATFORM WITH A SHEET OF PLYWOOD.
  • Page 15: Vl48Eg Grill Installation

    VL48EG Grill Installation- -Option- Compatible with both Vented Chase and HDS Parts List: *This Grill Meets Minimum Opening Air Free Requirements* [1] Louver Grill (ready to paint) This Kit comes with two installation options: Outer Trim Grill Mount - For a Quick and simple installation. [1] Outer Trim Grill Mount (ready to paint) Hidden Grill Mount - For a very clean installation with only the grill [1] Upper Frame for Hidden Grill Mount...
  • Page 16: Vl60Egs Side Grill

    VL60EGS Side Grill Installation - MQVL48, MQVLBG48 Option Not compatible with HDS System. ⚠ Grill openings must be within 2” of enclosure top. Contents of Kit: [Qty 2] Side Grill assemblies (ready to paint). This is to prevent excess heat from becoming trapped in the top of the chase.
  • Page 17: Vl48Hds Optional Heat Distribution System

    VL48HDS Optional Heat Distribution System -Option *Requires ZDV5FP6 Flex Pipe Kit (Contains 4 pcs. 5”diameter flex pipe 6’ long). Uses Kingsman VL48EG Grill Must be installed before front framing is in place. Minimum 151 Sq. In. Free Air Equivalent Plenum...
  • Page 18: Clearance To Combustibles

    MQVL48 / MQVLBG48 Clearance to Combustibles Front (Furniture, etc. from glass) 36” [92cm] ⚠ Side (Furniture, etc. from glass) 8-1/2” [21.6cm] NOTE If using insulation in vented Side (from Stand-offs of VLBG48 or Corner Kit) 0” [0cm] chase (i.e. for outside wall), Back (from Stand-offs) 0”...
  • Page 19: Mantel Clearances / Adjacent Wall

    MQVL48 / MQVLBG48 Mantel Clearances SIDE VIEW (MQVLBG48 Shown) A Combustible Mantel 151 sq. can be placed immediately in. Min. above the fireplace 3/4” 1 in. Min. opening. A Combustible Hearth can be placed immediately 28-1/2” below the fireplace (55” TV) opening.
  • Page 20: Mqvl48 Single Side

    MQVL48 Single Side Locating Your Appliance LOCATION KEY: Left Side Corner Flat on Wall 45° Corner As a Room Divider As an Island* Right Side Corner Exterior Wall Chase 20’ MAX *Island installation with a top vent is possible as long as the horizontal portion of the vent system does not 20’...
  • Page 21: Nailing Tab Guide

    MQVL48 Single Side -Nailing Tab Guide- [Qty] 4 Nailing Tabs are located on each side of the front frame. NOTE: If using the rear nailing tabs for cantilevered chase etc., refer to the Nailing Tab page for MQVLBG48 Bay Peninsula. Flat (As Shipped) Pull up 90°...
  • Page 22: Single Side Framing

    MQVL48 Single Side Framing TOP VIEW Stud Stud BACK WALL FRAMING 18-7/8” Framing Flush with Face FRAMING OVER FRONT TOP OF FIREPLACE FRAMING FRONT FIREPLACE FRAMING IN FRONT OF FIREPLACE Variable – Can be built out to desired depth EXTENDED FRAMING FRONT FIREPLACE EXTENDED FRAMING IN FRONT OF FIREPLACE...
  • Page 23: Using Tile Lip

    MQVL48 Single Side - Using Tile Lip A Tile Lip is supplied for attachment above the fireplace opening. This can be used as a standard tile edging or as a mount bracket for other surfaces like drywall or plywood. Set to desired height and attach through holes in face of fireplace. Install before applying the finishing materials.
  • Page 24: Vl48S1Bl / Vl48S1Ss -Surround Installation For Mqvl48

    VL48S1BL / VL48S1SS -Surround Installation for MQVL48 -Option NOTE: Install before applying the PARTS LIST: finishing materials. Install Tile Lip - [Qty 1] Surround Frame (supplied with fireplace) using second - [Qty 2] Black Side Fillers hole from top, as shown. This will provide - [Qty 1] Bottom Filler the required 5/8”...
  • Page 25 INSTALLATION: - Fireplace must be installed and wall surface must be finished. -Insert assembled Surround into fireplace opening. [Qty 4] Surround Tabs will fit into [Qty 4] Fireplace Slots. Surround Tabs -Insert [Qty 4] screws through the holes in the Surround Tabs and into the Fireplace.
  • Page 26: Mqvl48Sep Side Extension Panels

    MQVL48 Single Side- VL48SEP Side Extension Panels -Option- Contents if Kit: Qty 2 – Side Extension Panels Qty 4 - #6 Black Screws 4” 18-3/16” 19-7/16” Framing Details: FROM EDGE OF FIREPLACE TO OUTSIDE OF 2 X 4 HORIZONTAL FRAMING ABOVE TOP OF 19-3/16”...
  • Page 27: Glass Front Removal / Installation

    MQVL48 Glass Front Removal / Installation To remove Glass Front: 1. Remove the [Qty 4] Wing Nuts on the Upper Glass Retainer above the Glass Door Front and remove the Retainer. 2. Loosen the [Qty 4] Wing Nuts on the Lower Glass Retainer but do not remove. 3.
  • Page 28: Mqvlbg48 Bay Peninsula

    MQVLBG48 Bay Peninsula Locating Your Appliance LOCATION KEY: A. Corner Kit- Left Side B. Flat on Wall C. Corner Kit- Right Side D. Corner Kit- Left Side E. Corner Kit- Right Side F. 45° Corner G. As an Island* *Island installation with a top 20’...
  • Page 29: Bay Peninsula Framing

    MQVLBG48 Bay Peninsula -Framing OPTION A: Framing Attached to Side of Fireplace- For building out around the fireplace. NOTE: Appliance and framing structures are not load bearing. SIDE VIEW -TOP VIEW- BACK WALL FRAMING ON TOP OF FIREPLACE VARIABLE Can be built out to desired depth EXTENDED FRAMING IN FRONT OF FIREPLACE...
  • Page 30: Bay Peninsula Nailing Tabs And Framing

    MQVLBG48 Peninsula –Nailing Tabs and Framing OPTION A: Framing Attached to Side of Fireplace- For building out around the fireplace. Framing must be self- supporting. SIDE NAILING TAB Optional framing attached to side MIN. 151 of fireplace SQ. IN. ⚠ DO NOT COVER TOP OF PLATFORM WITH A SHEET OF PLYWOOD.
  • Page 31 VLBGCK - Corner Kit - for MQVLBG48/60/72 Peninsula Bay Option - MUST BE INSTALLED BEFORE ⚠ Warning: Failure to position the parts in accordance with these UNIT IS INSTALLED INTO FRAMING. diagrams or failure to use only parts specifically approved with this - CORNER KIT CAN BE INSTALLED appliance may result in property damage or personal injury.
  • Page 32 Do Not Apply Installation: Mill-Pac to IF USING Apply a small bead Front Glass PORCELAIN OR of Millpac to Firebox Gasket FLUTED LINERS: Cover Gasket. Insert Do Not Apply Remove [Qty 4] Firebox Cover into Mill-Pac to Apply Mill-Pac DT Screws from place from front of Front Glass to Gasket of...
  • Page 33: Vlbgck Corner Kit

    Install Inner Liner Panel: Remove Retainer NOTE: If you are from False using a Firebox Back Bottom Liner Kit (Glass, Porcelain, or Fiber), DO NOT INSTALL Inner Liner Panel from Corner Kit. A (Glass, Porcelain, or Fiber), Side Liner Kit will also be required.
  • Page 34: Using Tile Lip

    MQVLBG48 Bay Peninsula - Using Tile Lip Drywall Drywall 84 Square Inches Free Air Minimum MQVLBG48 Bay Peninsula -Facing Requirements Unit may be covered with combustible material (i.e. drywall) up to the fireplace opening. Option A: Open Chase at Ceiling Minimum 151 Sq.
  • Page 35: Front Glass Installation

    Enclave Series – Bay Peninsula Units- Front Glass Installation and Removal SILICONE SILICONE ALIGNMENT ⚠ IMPORTANT: Each corner must have a dab of high-temp silicone placed between the ball of the gasket and the corner glass. This will fully seal the firebox corners. Front Glass is placed in front of corner glass edge.
  • Page 36: Side Glass Door Removal And Installation

    Enclave Series – Bay Peninsula Units- – Side Glass Removal and Installation Remove Front Firebox Glass first. If the Side Glass Panel or another component must be cleaned or replaced, remove the 4 Wing Nuts from the Side Glass Door and remove Retainers, Glass Door Frame, and Glass. Spring Mechanism 60VLBG-126A Glass...
  • Page 37: Door And Glass Information

    Door and Glass Information MQVL48 / MQVLBG48 Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass.
  • Page 38: Mqvl48 / Mqvlbg48- Glass Safety Barrier Installation / Removal

    MQVL48 / MQVLBG48– Glass Safety Barrier Installation / Removal INSTALL SIDE GLASS FIRST. DECAL ON GLASS SHOULD FACE OUTSIDE. 16-3/16” 16-3/16” 54-5/8” 14-3/8” FRONT GLASS PANEL [QTY 1] SIDE GLASS PANELS [QTY 2] GLASS SUPPORTS INSERT GLASS INTO CLIPS PLACE GLASS INTO GLASS SUPPORTS.
  • Page 39: Component Locations

    MQVL48 / MQVLBG48 Component Locations TOP VIEW GAS LINE 120 VAC LIGHT 120 VAC VALVE DRIVER OPTIONAL MODULE BATTERY REMOTE PAIRING BUTTON (LED) BACKUP (SW1 SWITCH) REMOTE PAIRING BUTTON (SW1 SWITCH) DCHS Cover for Optional Remote Receiver- Millivolt or Proflame 1 Systems Only PROFLAME 1 C/W REMOTE RECEIVER &...
  • Page 40: Led Lighting

    MQVL48 / MQVLBG48 LED Lighting Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. LED Light Strip is Located Under the Firebox. LED LIGHT STRIP 584-X10 HARNESS YELLOW CONNECTOR GROUNDING STUD PROFLAME 2 MODULE LED CONTROLLER...
  • Page 41: Vl48Plb / Vl48Ple Porcelain Liner Installation

    VL48PLB / VL48PLE Porcelain Liner Installation Option -VL48PLB- BACK PANEL KIT NOTE: If using VLBGCK CORNER KIT, DO NOT USE BACK FILLER Inner Liner Panel from Corner Kit. Remove if installed. STEP ONE: Remove Liner Clips and screws from inside of firebox with a BACK LINER 1/4”...
  • Page 42: Mqvl48Rgb Glass Back Liner Installation

    MQVL48RGB Glass Back Liner Installation Option MQVL48RGB - BACK PANEL KIT STEP ONE: Remove Liner Clip and screws from inside of firebox with a 1/4” hex NOTE: Install CONTENTS: driver. Discard Back Clip MQVL48RGB Before GLASS BACK but Keep Screws. installing LINER X 3 MQVL48RGE...
  • Page 43: Mqvl48Rge Glass End Panel Installation

    MQVL48RGE Glass End Panel Installation Option -MQVL48RGE - END PANEL KIT ⚠ CAUTION – NOT TEMPERED GLASS- EXTREMELY FRAGILE – HANDLE WITH CARE NOTE: Back Glass Liners must be installed first. RIGHT LEFT SIDE SIDE GLASS GLASS NOTE: If using VLBGCK CORNER KIT and you are NOT installing PANEL PANEL a Glass End Panel, install Inner Liner Panel from Corner Kit before...
  • Page 44 STEP THREE: Engage Front Slot of Tab with DT Screw in side wall of firebox. There is no bottom attachment Screw. FRONT FIREBOX LEFT SIDE END PANEL Repeat actions for other side. NOTE: if you are using VLBGCK CORNER KIT, only one End Panel will be used. ⚠...
  • Page 45: Mqvl48Rlsb / Mqvl48Rlse Liner Installation

    MQVL48RLSB / MQVL48RLSE Stacked Brick Liner Installation Option MQVL48RLFB / MQVL48RLFE Fluted Liner Installation Option -MQVL48RLSB- BACK LINER KIT STEP ONE: Prepare the fireplace. BACK LINER Remove Upper Liner Clips from inside of firebox with a 1/4” hex driver. Liners are Identical No Left or Right...
  • Page 46 STEP FOUR: Install Lower Liner Clips [x4]. LOWER LINER CLIP X 4 LOWER LINER CLIP (X4) MEDIA TRAY STEP FIVE: Install Side Liners. Reinstall End Clips with DT Screws. See Step Five Reference Drawing on Previous Page. NOTE: If using VLBGCK CORNER KIT, remove Inner Liner Panel from Corner Kit if installed. ⚠...
  • Page 47: Mq Dealer Accessories - Mqvl48 / Mqvlbg48

    MQVL48 / MQVLBG48 MQ Dealer Accessories The following Accessories are available through MQ Dealers only. CRUSHED GLASS MEDIA ACCESSORY ITEM DESCRIPTION Spread the glass embers onto the false bottom and burner. MQG5C Ensure the glass embers do not excessively overlap as this will affect Decorative Ember Glass –Bronze the flame pattern.
  • Page 48 MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom.  MQRock2 MQRock3 MQRBD1 NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur.  Do Not Cover any part of the burner tube with logs as sooting may occur. ...
  • Page 49: Mqrbd3 5 Piece Driftwood Log Set

    MQRBD3 -5 Piece Driftwood Log Set- Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. ⚠ NOTE LOG 1  For best flame pattern it LOG 3 is essential to spread supplied Crushed Glass or MQEMBER directly LOG 4...
  • Page 50: Mqlogf48D - 6 Pc. Driftwood Log Set

    Enclave Series MQLOGF48D OPTION Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories Enclave Series MQRBBW OPTION ⚠ NOTE  Pilot area must not be covered, as delayed ignition could occur ...
  • Page 51: Gas Line Installation / Gas Specifications Chart

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 52: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When ...
  • Page 53: Annual Inspection List

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 54: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System ⚠ WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is...
  • Page 55: Burner System Maintenance

    Burner System Maintenance MQVL48 / MQVLBG48 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. ⚠ -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 56: Gas Conversion Part A

    -Gas Conversion Part A- MQVL48 / MQVLBG48 Models: MQVL48N, MQVL48NE, MQVL48NE2, MQVL48LP, MQVL48LPE, MQVL48LPE2 MQVLBG48N, MQVLBG48NE, MQVLBG48NE2, MQVLBG48LP, MQVLBG48LPE, MQVLBG48LPE2 Kit Number Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) 48VL-CKLP LP Conversion 1001-P167SI 1000-253...
  • Page 57: Gas Conversion For Top Convertible Pilot - Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 58: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 59: Burner Tube Removal

    MQVL48 / MQVLBG48 False Bottom Removal (Media Tray) In order to access the Burner Tube and Burner Pan, the False Bottom must be removed. STEP 1:MQVLBG48 Units Remove Retainers from STEP 2: Remove the [Qty 8] Screws shown below. each end of False Bottom. False Bottom can now be removed from fireplace.
  • Page 60: Proflame

    Proflame 1 -IPI Electronic Ignition System- Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the Remote Receiver CPI/IPI Switch (Continuous Pilot Module Ignition/Intermittent Pilot Ignition) located on the...
  • Page 61: Remote Control Operation

    Proflame 1 -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 62: Proflame 1 Ipi System Parts List

    Proflame 1 -IPI System Parts List- PART NO. DESCRIPTION 1006-P002SI Valve IPI Hi/Lo NG 11. 1002-P012SI IPI Stepper Kit - LP 907.012 1006-P003SI Valve IPI Hi/Lo LP 12. 1002-P013SI IPI Stepper Kit - NG 907.013 1002-P302SI IPI Ignition Board 13. 1002-P014SI IPI Reg Kit - LP Hi-Lo 907.014 1002-P047SI Pilot Assembly-LP -24”...
  • Page 63: Configuration #2: Remote On/Off And Manual Hi/Lo Capabilities

    Proflame 1- Configuration #2: Remote ON/OFF and Manual HI/LO Capabilities OPTIONAL: For units with remote HI/LO capabilities, a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown. SCHEMATIC PICTURE NOTE: Fan Option...
  • Page 64: Configuration #3: Remote On/Off, Variable Hi/Lo, And Fan Capabilities

    Proflame 1- Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities Refer to the fan installation/removal section for fan installation. NOTE: This Configuration is not available on all models of SCHEMATIC fireplace. Check with your dealer. NOTE: Fan Option PICTURE is not available on some models of fireplace.
  • Page 65: Operating The Receiver Without Batteries- Millivolt And Proflame 1

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 66: Electronic Ignition Lighting Instructions

    - Lighting Instructions - Intermittent Pilot Ignition System (IPI) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has run out with the glass door opened or removed.
  • Page 67: Proflame 2 Parts List

    Proflame 2 –NE2 / LPE2 -IPI System Parts List- IPI PROFLAME 2 - COMPONENT PARTS IPI - PF1 and PF2 Common Components PART NO. DESCRIPTION PART NO. DESCRIPTION 1005-P001SI Valve IPI Proflame PF2 885.001 NG - Stepper 12. 1002-P033SI TC - Pilot Burner IPI (Assembled) NG 199.033 1005-P002SI Valve IPI Proflame PF2 885.002 LP - Stepper 13.
  • Page 68: Proflame 2 Module And Remote Control

    Proflame 2 Module and Remote Control PRESS BUTTON REMOTE PAIRING BUTTON (SW1 Switch) Pairing Remote Control Press the SW1 button until you hear three beeps.   Install the 3 AAA batteries in the battery bay, located on the  Within 10 seconds press the button again until you base of the Remote Control.
  • Page 69: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a flame. The CPI (Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather. When the firebox and exhaust vent are warm, exhaust gasses will readily flow out of the firebox.
  • Page 70: Proflame 2 Remote Control Operation

    Proflame 2 Remote Control...
  • Page 71 Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 73: Vent Terminal Clearances

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 74: General Vent Installation

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with 5 x 8 M&G-Duravent Direct...
  • Page 75: Venting Routes And Components

    Venting Routes And Components Venting Routes and Components How to Use the Horizontal Vent Table Since it is very important that the vent system maintain its 1. Determine the height of the system and the number of balance between the combustion air intake and the flue gas bends required.
  • Page 76: Venting Straight Up Through Roof

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 77 -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z58VT Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re- circulation of exhaust products. For additional requirements check local codes.) 24” 18” MIN Clearance above highest point of exit on roof 18 inches (45cm) 43ft...
  • Page 78: Approved For Power Vent

    Approved for Power Vent PVH58 / PVH58FM - This appliance is approved for use with Kingsman Horizontal Power Vents - A Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 79: Pvh58 Parts List

    Power Vent Parts List – 5/8 Venting NUMBER DESCRIPTION PVH58 Horizontal Power Vent Starter Kit ‐ Exterior Mount PVH58FM Horizontal Power Vent Kit ‐ Flush Mount Note: Must use a one foot section of 5/8 DV hard pipe to connect to the Power Vent Termination (not supplied) CHOOSE CONTROL MODULE OR HARNESS DEPENDENT ON VALVE SYSTEM PVC58MV Power Vent Control Module ‐...
  • Page 80: Fireplace Models

    (IPI System 2) Fireplace Heater Rated NG, MQVLBG48NE2 Heater Rated NG, Ceramic Glass, Low E Ceramic Glass, Low E Tempered Glass MQVL48NE2 Tempered Safety Glass Barrier, Lights Safety Barrier, Lights Peninsula Bay Fireplace (IPI System 2) (IPI System 2) Fireplace Heater Rated LP,...
  • Page 81: Mqvl48 / Mqvlbg48 Parts List

    VL48AVP Adjustable Vented Platform- Mounting System (MQVL48LPE2) 48VL-BNE2 Burner Assembly- Natural Gas c/w Valve Base for fireplace- Adjusts from 14-3/4” to System (MQVL48NE2) 27-5/16”. MQVL48 / MQVL48B Options Conversion Kit WARNING: DO NOT OPERATE THIS APPLIANCE WITHOUT 48VL-CKLPH LP Conversion Kit for MQVL48 Millivolt...
  • Page 82 Switch Ivory (1451/001) 1000-218 Cover Ivory (86001/001) 1000-227 Orifice Brass - (State Size) 1000-255 FP15GC Stainless Steel Gas Connector Kingsman Fireplace Venting Z58VT Vertical Vent Termination Z58HT Horizontal Vent Termination FDVHSCU Safety Cage for Horizontal Termination Z58AIS Attic Insulation Shield...
  • Page 83: Limited Lifetime Warranty

    During the first year after installation of the appliance, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents