Model Numbers:
ZCVRB47N, ZCVRB47NE, ZCVRB47LP, ZCVRB47LPE
MQZCVRB47NE2, MQZCVRB47LPE2
Certified to:
ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters • CSA 2.17-2017
Installation Instructions
SERENE
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
C#400720
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada April 16, 2019
Part# 47ZCV-MAN17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZCVRB47LP and is the answer not in the manual?

Questions and answers

Summary of Contents for Kingsman ZCVRB47LP

  • Page 1 Installation Instructions C#400720 Model Numbers: ZCVRB47N, ZCVRB47NE, ZCVRB47LP, ZCVRB47LPE MQZCVRB47NE2, MQZCVRB47LPE2 Certified to: ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters • CSA 2.17-2017 SERENE This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    Vented Chase – Style 1 – Opening With No Grill..................... 20-21 Vented Chase – Style 2 – Opening With Grill....................22-23 Vented Chase -Style 2 – Opening With Grill - Kingsman V46EG..............V46EG Grill Installation............................ VL60EGS Side Grill Installation........................Framing Dimensions –Vented Chase -Ventilation Plates Removed..............
  • Page 3 Burner System Removal/Installation Guide...................... LOGS AND MEDIA ULK2 Universal Light Kit (Optional Accent Lighting Kit)................... 49-50 LED Lighting..............................RBCB1 -Cannonballs- Installation Instructions....................MQ Dealer Accessories for ZCVRB47......................53-54 MQRBD3 5 Piece Driftwood Log Set……………………………………………………………………....PROFLAME 1 IPI SYSTEM IPI Electronic Ignition System........................... Remote Control Operation..........................
  • Page 4: Safety Screen Installation / Removal

    47ZCVCSS Safety Screen Installation / Removal ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screen. Engage slots in top of Screen Mount Brackets onto screw in fireplace opening and push bottom in.
  • Page 5: Pre-Installation Questions And Answers / Operating Instructions

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 6: Warnings, Installations, And Operations

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 7 Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Framing Your Gas Fireplace

    ZCVRB47 Framing Your Gas Fireplace This section is intended for qualified installers only. Vertical Venting in Cold Climates Before beginning, make note of where the gas and In cold climate conditions where temperatures go below electrical accesses are located on the unit. This will -10 degrees Celsius or 14 degrees Fahrenheit, we streamline the construction process.
  • Page 10: Nailing Tab Guide

    ZCVRB47 Nailing Tab Guide [Qty] 2 Nailing Tabs are located on each side of the fireplace front frame. These Nailing Tabs can be used in two ways: 1/2” Drywall Flush with Face of Fireplace Framing Flush with Face of Fireplace Fireplace and Combustible Wall to be covered with a Fireplace to be covered with Non-Combustibles (e.g.
  • Page 11: Zcvrb47 -Facing Requirements- All Units- Unvented Or Vented Chase

    ZCVRB47 -Facing Requirements- ALL UNITS- Unvented Chase or Vented Chase- Finishing Recommendations (Obtained from professional NOTE: ANY MATERIALS COVERING THE FACE OF THE construction contractors and finishers): FIREPLACE BESIDE AND ABOVE THE FIREPLACE OPENING MUST BE NON-COMBUSTIBLE (i.e. brick,  Frame unit with metal studs (minimum 20 gauge).Wooden stone, tile, concrete board).
  • Page 12: Tile Lip Kit- V47Ptlk

    V47PTLK ZCVRB47 Tile Lip Kit ZCVRB47 Tile Lip Kit (V47PTLK): -1 Bottom Piece -2 Sides - [Qty] 11 Pan Head DT Screws SIDE VIEW Side Side Bottom 5/8”...
  • Page 13: Fireplace Installations In Covered Outdoor Locations

    Intertek safety certification will not apply to this installation method. This installation method must be deemed acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed. Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement.
  • Page 14: Locating Your Appliance / Fireplace Dimensions

    ZCVRB47 Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 15: Zcvrb47 -Unvented Chase Vs Vented Chase- Choose Your Installation

    See “Unvented Chase” Framing Section  A minimum opening of 105 square inches of ventilation area is required. Kingsman V46EG or VL60EGS Grills may be used.   If a custom grill is used, free air opening must total 105 square inches with no sloping louvers.
  • Page 16: Framing Dimensions -Unvented Chase- Ventilation Plates In Place -As Shipped

    ZCVRB47- Framing Dimensions –Unvented Chase-Ventilation Plates In Place- As Shipped Determine whether face of fireplace will be:  Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).  Flush with framing (to be covered with concrete board for a Flat Wall appearance). ...
  • Page 17: Mantel Clearances - Unvented Chase - Ventilation Plates In Place -As Shipped

    ZCVRB47 -Mantel Clearances –Unvented Chase- Ventilation Plates In Place -As Shipped Before installing any mantels it is important to determine the combustibility of its material(s). There Mantel Dimensions are from front are two types of mantels to consider: face or Non-Combustible Facing Combustible and Non-Combustible.
  • Page 18: Clearance To Combustibles - Unvented Chase -Ventilation Plates In Place -As Shipped

    ZCVRB47 -Clearance to Combustibles –Unvented Chase- Ventilation Plates In Place – As Shipped Clearance to Combustibles ZCVRB47 Unvented Chase Front 36” [92cm] Back (from Stand-offs) 0” [0cm] Side (from Stand-offs) 0” [0cm] Floor 0” [0cm] Minimum Ceiling Height (from bottom of fireplace) 70”...
  • Page 19: Vented Chase -Removal Of Ventilation Plates

    ZCVRB47 -Vented Chase –Removal of Ventilation Plates- See Framing for Vented Chase ⚠ CAUTION: Ventilation Plates must be removed before ZCVRB47 is installed into a Vented Chase. STEP 1: Remove [Qty 2] Outer Top Covers. STEP 2: Remove [Qty 2] Ventilation Plates inside opening. STEP 1: Remove [Qty 2] Outer Top Covers STEP 2: Remove [Qty 2] Ventilation Plates.
  • Page 20: Vented Chase - Style 1 - Opening With No Grill

    ZCVRB47 – Vented Chase – Style 1 – OPENING WITH NO GRILL ⚠ NOTE:  VENTILATION PLATES MUST BE HEAT CANNOT BE DISCHARGED INTO THE WALLS, FLOOR, OR REMOVED. CEILING. Heat must exit through the required vented chase opening near ...
  • Page 21 ZCVRB47 –Vented Chase- Style 1 – OPENING WITH NO GRILL VENTILATION PLATES MUST BE REMOVED Ceiling / Enclosure Top Open Area Open Area ⚠ NOTE: Minimum Opening is 105 Sq. In. MIN 105 SQ. IN. MINIMUM 105 sq. inches of free air. 1-1/4”...
  • Page 22: Vented Chase - Style 2 - Opening With Grill

    Please follow the current CSA C22.1 Canadian Electrical enclosure top. Code or the National Electrical Code; ANSI/NFPA 70 when  If Kingsman V46EG Grill is used, minimum rough installed in the United States. opening required is 2-5/8” x 46-3/4”. Any obstacles, ⚠...
  • Page 23: Vented Chase – Style 2 – Opening With Grill

    ZCVRB47 – Vented Chase – Style 2 – OPENING WITH GRILL VENTILATION PLATES MUST BE REMOVED Grill Opening must be within 2” of Enclosure Top FRAMING TO CEILING- MINIMUM ENCLOSURE- GRILLS AT FRONT AND BACK FRAMING TO CEILING - Each grill must be 105 MINIMUM ENCLOSURE- square inches free air SIDE GRILLS...
  • Page 24: Vented Chase -Style 2 - Opening With Grill - Kingsman V46Eg

    ZCVRB47 –Vented Chase -Style 2 – OPENING WITH GRILL - Kingsman V46EG VENTILATION PLATES MUST BE REMOVED. 2” MAX Enclosure Top Sealed Enclosure Top to Grill Opening ⚠ NOTE: If using insulation in vented chase 2-5/8" x 46-3/4" 2-5/8" x 46-3/4"...
  • Page 25: V46Eg Grill Installation

    ZCVRB47 V46EG Grill Installation Option Parts List: This Kit comes with two installation options: Outer Trim Grill Mount - For a Quick and simple installation. [1] Louver Grill (ready to paint) Hidden Grill Mount - For a very clean installation with only the grill [1] Outer Trim Grill Mount (ready to paint) visible in the finished opening.
  • Page 26: Vl60Egs Side Grill Installation

    VL60EGS Side Grill Installation ZCVRB47 Option Contents of Kit: [Qty 2] Side Grill assemblies (ready to paint). 15-1/4” x 6-5/8” Tall opening required. Fits into 6-5/8” Opening Pressure Fit into 15-1/4” Opening Pressure Point ⚠ Grill openings must be within 2” of enclosure top. This is to prevent excess heat from becoming trapped in the top of the chase.
  • Page 27: Framing Dimensions -Vented Chase -Ventilation Plates Removed

    ZCVRB47 -Framing Dimensions –Vented Chase -Ventilation Plates Removed Determine whether face of fireplace will be:  Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).  Flush with framing (to be covered with concrete board for a Flat Wall appearance). Refer to Nailing Tab Guide section also.
  • Page 28: Optional Recessed Cavity Dimensions

    ZCVRB47 – Optional Recessed Cavity Dimensions  Recessed Cavity may begin immediately above top header (i.e. 4” for 2 x 4 with drywall).  May be 3-1/2” deep, with up to 3/4”combustible on back wall (i.e. plywood). NOTE: If this surface is covered with drywall, recess will be 3”...
  • Page 29: Mantel Clearances -Vented Chase -Ventilation Plates Removed

    ZCVRB47 -Mantel Clearances –Vented Chase -Ventilation Plates Removed Before installing any mantels it is important to determine the Sealed Enclosure combustibility of its material(s). There are two types of mantels to consider: Combustible and Non-Combustible. Mantel Dimensions A Combustible Mantel is one that are from front face consists of material(s) that may or Non-Combustible...
  • Page 30: Clearance To Combustibles -Vented Chase -Ventilation Plates Removed

    ZCVRB47 -Clearance to Combustibles –Vented Chase -Ventilation Plates Removed- Clearance to Combustibles ZCVRB47 Vented Chase Front 36” [92cm] Back (from Stand-offs) 0” [0cm] Side (from Stand-offs) 0” [0cm] Floor 0” [0cm] Minimum Ceiling Height (from bottom of fireplace) 70” [179cm] Top (from Stand-offs) 0”...
  • Page 31: Surround Dimensions / Clearances

    ZCVRB47S1BL / ZCV47S1SS Surround Dimensions Surround Frames are 3/4” thick, by 1-1/2” wide.   Gap between surround and face of fireplace is variable- 5/8”, 7/8”, or 1-1/8”- determined by which mount hole is used. The Fireplace may be covered with non-combustibles up to within 1/8” on sides of opening, and within 1/2” of opening ...
  • Page 32: Surround Installation

    ZCVRB47 Surround Installation Surrounds: ZCVRB47S1BL (Black), ZCVRB47S1SS (Stainless Steel) Dimensions: (44-1/2”W x 18-7/8”) Each kit contains: (Qty-1) Surround Frame Surround Frames are 3/4” thick, by 1-1/2” wide.  Gap between surround and face of fireplace is variable- 5/8”, 7/8”, or 1-1/8”- determined by which mount hole is ...
  • Page 33: Uhs Box

    ZCVRB47 51UHS Box – For Millivolt or Proflame 1 Units Included with base model. The 51-UHS is designed for millivolt and IPI units for in- unit installation of the Remote Receiver, Fan Control Module, and the IPI Module. NOTE: When using a remote control, the 51-UHS must be used.
  • Page 34: Fan Kit Installation

    ZCVRB47 Z46FK Fan Kit Installation Fan Kit should be installed before facing material is applied or surround is installed. To remove fan for service, the burner pan must be removed and work done through the opening (See Burner System Removal section). Fan Speed Control MUST be...
  • Page 35: Split Receptacle- Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 36: Door And Glass Information

    ZCVRB47 Door and Glass Information Glass Cleaning Removal of the Glass Door ZCVRB47 It will be necessary to clean the glass periodically. During start- up, condensation, which is normal, forms on the inside of the Remove the door by unlatching the 2 top latches. glass and causes dust, lint etc.
  • Page 37: Valve Access Cover Removal / Removable Lower Face Panel

    ZCVRB47 Valve Access Cover Removal Remove the Safety Screen in order to access igniter and valve controls. Refer to Safety Screen Installation / Removal instructions. Safety Screen ZCVRB47 Removable Lower Face Panel Installers Note: The Lower Face Panel is removable. This allows all necessary gas line and electrical connections to be made easily. Once the installation is complete attach the Lower Face Panel with the supplied screws.
  • Page 38: Zcv47Pl Liner Installation

    ZCVRB47PL Porcelain Liner Installation ZCVRB47PRL Parts List: [1] – Back Liner [1] – Left Side Liner [1] – Right Side Liner [4] – DT Screws Pilot BACK REMOVE ALL 6 BRICK CLIPS REMOVE LEFT RIGHT PILOT SHIELD Screw Screw Pilot Screw Screw INSTALL BACK...
  • Page 39 When installing Back Porcelain Liner (Step 3): Pull bottom of Back Liner forward and install screw into hole. BACK LINER INCORRECT HOLE CORRECT CORRECT When installing Side Porcelain Liners (Step 4): Push Side Porcelain Liners against side wall of firebox. Use a DT Screw to create a hole if none exists. PUSH SIDE LINER AGAINST FIREBOX SIDE...
  • Page 40: Mqvrb46Rlf Liner Installation

    MQZCVRB47RLF Fluted Liner Installation MQZCVRB47RLF Parts List: [1] – Back Liner [1] – Left Side Liner [1] – Right Side Liner Pilot BACK REMOVE ALL 6 BRICK CLIPS REMOVE LEFT RIGHT PILOT SHIELD Screw Screw Pilot Screw Screw INSTALL BACK LINER BACK RIGHT...
  • Page 41: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 42: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING  Immediately call your gas supplier from a neighbour’s phone. Follow the This appliance has a pilot which must be lighted by hand.
  • Page 43: Annual Inspection List For Determining Safe Operation Of A Direct Vent Gas Fireplace

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 44: Burner System Maintenance

    ZCVRB47 Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. ⚠ -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 45: Gas Conversion Part A

    ZCVRB47 Gas Conversion Part A Models: ZCVRB47N, ZCVRB47NE, ZCVRB47LP, ZCVRB47LPE, MQZCVRB47NE2, MQZCVRB47LPE2 Kit Number Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) 47ZCVRB-CKLP LP Conversion 1001-P167SI 1000-P201VE Fully 1001-P202SI -Millivolt- #30 (977.167) Open (0.907.202) 47ZCVRB-CKNG...
  • Page 46: Gas Conversion Kit For Top Convertible Pilot Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 47: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 48: Burner Tube Removal

    ZCVRB47 Burner System Removal/Installation Guide ⚠ Warning- Turn off Unit and allow to cool before cleaning. Only a Qualified service technician should service and repair this appliance. Burner Pan Pilot Shield #5143ZDV-258-3 False Bottom #47ZCVRB-256 Remove the Glass Door from the unit. Remove liners if present. Remove DT screws and lift out the False Bottom. Remove the DT screws around the perimeter of the burner pan.
  • Page 49: Ulk2 Universal Light Kit (Optional Accent Lighting Kit)

    ZCVRB47 ULK2 Universal Light Kit ( Optional Accent Lighting Kit) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Contents of Kit:  [2] 12V Halogen Lamps  Lamp Plate with Insulated Studs & wiring ...
  • Page 50 Screw Screw STEP 3: Place Lamps in position in firebox. Attach to fireplace with a single screw at the locations shown above for each unit. Lamps can be placed facing upward or sideways. Replace burner tube and false bottom, along with pilot shield.
  • Page 51: Led Lighting

    MQZCV47 LED Lighting Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. LED LIGHT STRIP 584-X10 HARNESS YELLOW CONNECTOR GROUNDING STUD PROFLAME 2 MODULE LED CONTROLLER MODULE BATTERY BACKUP ZCVRB47 –...
  • Page 52: Rbcb1 -Cannonballs- Installation Instructions

    RBCB1 -Cannonballs- Installation Instructions Assorted size and colors. Place randomly as desired inside fireplace. Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur. ...
  • Page 53: Mq Dealer Accessories For Zcvrb47

    MQ Dealer Accessories for ZCVRB47 The following Accessories are available through MQ Dealers only. GLASS (MQG5W, MQG5C, MQG5A, MQG5B) ACCESSORY ITEM DESCRIPTION  If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass embers do not excessively MQG5W Decorative Glass 1/2”...
  • Page 54 MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom.  MQRock2 MQRock3 MQRBD1 NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur.  Do Not Cover any part of the burner tube with logs as sooting may occur. ...
  • Page 55: Mqrbd3 5 Piece Driftwood Log Set

    MQRBD3 -5 Piece Driftwood Log Set- Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. ⚠ NOTE LOG 1  For best flame pattern it LOG 3 is essential to spread supplied Crushed Glass or MQEMBER directly LOG 4...
  • Page 56: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview Cover The IPI system is an advanced burner controller that provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 57: Remote Control Operation

    -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 58: Ipi Electronic Ignition Parts List - Standard System

    Proflame 1 -IPI System Parts List- PART NO. DESCRIPTION 1006-P002SI Valve IPI Hi/Lo NG 11. 1002-P012SI IPI Stepper Kit - LP 907.012 1006-P003SI Valve IPI Hi/Lo LP 12. 1002-P013SI IPI Stepper Kit - NG 907.013 1002-P302SI IPI Ignition Board 13. 1002-P014SI IPI Reg Kit - LP Hi-Lo 907.014 1002-P047SI Pilot Assembly-LP -24”...
  • Page 59: Configuration #1: Basic System

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 60: Configuration #2: Remote On/Off

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 61: Egtm / Gtm System -No Batteries

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 62: Configuration #3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 63: Ipi Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 64: Proflame 2 Parts List

    Proflame 2 –NE2 / LPE2 -IPI System Parts List- IPI PROFLAME 2 - COMPONENT PARTS IPI - PF1 and PF2 Common Components PART NO. DESCRIPTION PART NO. DESCRIPTION 1005-P001SI Valve IPI Proflame PF2 885.001 NG - Stepper 12. 1002-P033SI TC - Pilot Burner IPI (Assembled) NG 199.033 1005-P002SI Valve IPI Proflame PF2 885.002 LP - Stepper 13.
  • Page 65: Proflame 2 Ifc Module And Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button  Within 10 seconds press the button again until Pairing Remote Control: you hear it beep. ...
  • Page 66: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a LCD Display flame. The CPI (Continuous Pilot Ignition) setting will keep the ON / OFF Key firebox and fireplace exhaust vent warm during cold weather.
  • Page 67: Remote Flame Control, Room Thermostat

    Proflame 2 Remote Control...
  • Page 68: Smart Thermostat, Fan Speed Control, Remote Dimmer Control

    Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 70: Vent Termination

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 71: General Vent Installation Information

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with M & G-Duravent Direct Vent system (Duravent Pro), BDM Pro Form Direct Vent, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 72: Horizontal Venting Table

    Venting Routes And Components Since it is very important that the vent system The maximum vertical run is 43 ft/13.1 meters. maintain its balance between the combustion air intake Special Note: For each 45 degree bend installed in the and the flue gas exhaust, certain limitations as to vent horizontal run, the length of the horizontal run must be configurations apply and must be strictly adhered to.
  • Page 73: Horizontal Snorkel Terminations

    ZCVRB47 Horizontal Snorkel Terminations Z47ST24 / Z47ST36 Two snorkel terminations are available if a vertical rise is necessary on the exterior side of a building: Z47ST24 (24” Tall, 14-1/2” Center to Center) Z47ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures. If the Snorkel Termination is to be located below grade, a window well is recommended with adequate and proper drainage as per local codes.
  • Page 74: Vertical Venting

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 75 -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. FDVVT40 Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re- circulation of exhaust products. For additional requirements check local codes.) 24” 18” MIN Clearance above highest point of exit on roof 18 inches (45cm) 43ft...
  • Page 76: Co Linear Flex Kits

    Fireplace Installations Using Co Linear Flex Kits STANDARD VERTICAL TERMINATION CAP 46DVA-VC DIRECT VENT CHIMNEY LINER TERMINATION KIT (BASEPLATE & CO-LINEAR TO CO-AXIAL ADAPTER) 46DVA-GK (3”) HIGH WIND TERMINATION CAP 46DVA-VCH FLEX LINER IDVVT36 CO-LINEAR TERMINATION CO-AXIAL TO CO-LINEAR APPLIANCE CONNECTOR 46DVA-GCL SEAL PLATE HARD PIPE ADAPTER...
  • Page 77: Glass Safety / Termination Cap Safety -All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 78: Approved For Power Vent Pvh58 / Pvh58Fm

    Approved for Power Vent PVH58 / PVH58FM - This appliance is approved for use with a Kingsman PVH58 Horizontal Power Vent - A Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 79: Pvh58 Parts List

    PVH58 / PVH58FM Power Vent Parts List NOTE: THE HARD PIPE VENTING AND ADAPTERS IN THIS SECTION ARE TO BE USED IN CONJUNCTION WITH A PVH58 POWER VENT ONLY FOR THE VRB46 PART NUMBER DESCRIPTION PVH58 HORIZONTAL POWER VENT TERMINATION Listed for Canada and USA PVH58FM HORIZONTAL POWER VENT TERMINATION...
  • Page 80: Parts Lists

    Propane 44MQ-200A2 Burner Tube (Series II) ZCVRB47LPE Fireplace Linear, IPI Valve (as 47ZRB-BLPSI Burner Assembly- Propane c/w Valve above) Propane System (ZCVRB47LP) 47ZRB-BNGSI Burner Assembly- Natural Gas c/w Valve MQZCVRB47LPE2 Fireplace Linear, Proflame 2 IPI System (ZCVRB47N) Remote‐Thermostat‐Mod‐Fan‐LED ‐ 47ZRB-BLPSIE...
  • Page 81 Remote Control IPI PF1‐ EGTFRCN Kingsman Fireplace Venting Thermostat/Modulating/Fan ‐ NG Horizontal Vent Starter Kit - 3 FT Length ZDVHSK Remote Control IPI PF1 ‐ EGTFRCP Horizontal Vent Termination, Wall Thermostat/Modulating/Fan ‐ LP Thimble, 36” Flex Pipe, Mill Pac Horizontal Vent Starter Kit - 5 FT Length...
  • Page 82: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 83: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

This manual is also suitable for: