Table of Contents

Advertisement

Quick Links

Installation Instructions
Model Numbers:
Certified to:
- Certified for use with Adjustable Vented Platform (AVP), and Heat Distribution System (HDS) -
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Leave the building immediately.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
 If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use
with other gases, unless a certified kit is used.
A Division of R-Co. Inc. 2340 Logan Ave. Winnipeg, Manitoba Canada R2R 2V3 Ph.: (204) 632-1962
Single Side Units:
MQVL48N, MQVL48LP, MQVL48NE, MQVL48LPE
VL48N, VL48LP, VL48NE, VL48LPE
Bay Peninsula Units:
MQVLB48N, MQVLB48LP, MQVLB48NE, MQVLB48LPE
VLB48N, VLB48LP, VLB48NE, VLB48LPE
ANSI Z21.88-2017/CSA 2.33-2017 and CSA2.17-2017
VENTED GAS FIREPLACE HEATER
CONSUMER: Retain this manual for future reference.
Printed in Canada May 1, 2018 Part# 48VL-MAN17
ENCLAVE

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman MQVL48N

  • Page 1: Cover

    Installation Instructions Single Side Units: Model Numbers: ENCLAVE MQVL48N, MQVL48LP, MQVL48NE, MQVL48LPE VL48N, VL48LP, VL48NE, VL48LPE Bay Peninsula Units: MQVLB48N, MQVLB48LP, MQVLB48NE, MQVLB48LPE VLB48N, VLB48LP, VLB48NE, VLB48LPE Certified to: ANSI Z21.88-2017/CSA 2.33-2017 and CSA2.17-2017 VENTED GAS FIREPLACE HEATER - Certified for use with Adjustable Vented Platform (AVP), and Heat Distribution System (HDS) - ⚠...
  • Page 2: Warnings

    IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE.  If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.  Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 3: Warnings

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 4: Table Of Contents

    Mobile Home/Manufactured Housing Installation....................INSTALLATION & FRAMING Framing Your Gas Fireplace........................... Marquis MQVL48 / MQVLB48 Units - Vented Chase Requirements..............Kingsman VL48 / VLB48 Units - Vented Chase Requirements................VL48AVP Optional Adjustable Vented Platform Base.................... 12-13 Framing – Platform Base............................
  • Page 5 MQROCK2, MQROCK3, MQRBD1........................MQ STONE Decorative Stone Set.......................... MQEMBER................................MQRBD3 5 Piece Driftwood Log Set........................Burner System Gas Line Installation / Gas Specifications Chart....................Millivolt System, Lighting, and Burner Control......................Troubleshooting the Gas Control System....................... Burner System Maintenance........................... Gas Conversion Part A............................Gas Conversion for Top Convertible Pilot –...
  • Page 6: Installation Requirements For The Commonwealth Of Massachusetts

    Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 7: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 9: Framing Your Gas Fireplace

    MQVL48 / MQVLB48 Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 10: Marquis Mqvl48 / Mqvlb48 Units - Vented Chase Requirements

    Optional – Secondary Chase Ceiling Vent can be added 2” MAX from 2” MAX from top of Chase top of Chase Uses Kingsman Min 151 Sq. In. Uses Kingsman V46EG Grill Must be in the V46EG Grill same Pressure Minimum 151 Sq.
  • Page 11: Kingsman Vl48 / Vlb48 Units - Vented Chase Requirements

    Kingsman VL48 / VLB48 Units - Vented Chase Requirements Models VL48N, VL48LP, VL48NE, VL48LPE, VLB48N, VLB48LP, VLB48NE, VLB48LPE These units are available with Safety Screens only. Ceiling 2-1/4” MIN 56-1/8” MIN The Chase is vented through MINIMUM Opening is 2-1/4” x 56-1/8”...
  • Page 12: Vl48Avp Optional Adjustable Vented Platform Base

    VL48AVP Adjustable Vented Platform for MQVL48 / MQVLB48 -OPTION The Adjustable Vented Platform is an optional installation base. Height is variable from approximately 14-3/4” to 27-1/4”. Venting slots are provided at the bottom and between the fireplace and the platform. 9-3/4”...
  • Page 13 STEP TWO: ASSEMBLE TOP REAR BRACE INNER SIDE INNER PANEL INNER SIDE SIDE PANEL PANEL OUTER OUTER SIDE FRONT OUTER PANEL PANEL FRONT PANEL 2. Assemble Top using supplied screws. INNER SIDE PANEL INNER INNER SIDE SIDE PANEL PANEL STEP THREE: ASSEMBLE PLATFORM AND SET AT DESIRED HEIGHT 3.
  • Page 14: Framing - Platform Base

    MQVL48 / MQVLB48 Framing – Platform Base A Platform Base has air opening requirements that must be met. Top of Platform Must Have Minimum 480 Square Inches Free Air Opening ⚠ DO NOT COVER TOP OF PLATFORM WITH A SHEET OF PLYWOOD.
  • Page 15: Vl48Eg Grill Installation

    VL48EG Grill Installation- -Option- Compatible with both Vented Chase and HDS *This Grill Meets Minimum Opening Air Free Requirements* Parts List: [1] Louver Grill (ready to paint) This Kit comes with two installation options: Outer Trim Grill Mount - For a Quick and simple installation. [1] Outer Trim Grill Mount (ready to paint) Hidden Grill Mount - For a very clean installation with only the [1] Upper Frame for Hidden Grill Mount...
  • Page 16: Vl48Hds Optional Heat Distribution System

    VL48HDS Optional Heat Distribution System -for MQVL48 / MQVLB48 Uses Kingsman VL48EG Grill Must be installed before front framing is in place. Minimum 151 Sq. In. Free Air Equivalent Plenum Connect only the two center pipes when venting to an optional secondary chase vent.
  • Page 17: Clearance To Combustibles

    MQVL48 / MQVLB48 Clearance to Combustibles Front (Furniture, etc. from glass) 36” [92cm] Side (Furniture, etc. from glass) 36” [92cm] Side (from Stand-offs of VLB48 or Corner Kit) 0” [0cm] ⚠ NOTE Back (from Stand-offs) 0” [0cm] If using insulation in vented chase (i.e.
  • Page 18: Mantel Clearances

    MQVL48 – MQVLB48 Mantel Clearances SIDE VIEW MQVL48 – MQVLB48 (MQVLB48 Shown) A Combustible Mantel 151 sq. can be placed immediately in. Min. above the fireplace 3/4” 1 in. Min. opening. A Combustible Hearth can be placed immediately 28-1/2” below the fireplace (55”...
  • Page 19: Locating Your Appliance

    MQVL48 Single Side Locating Your Appliance LOCATION KEY: Left Side Corner Flat on Wall 45° Corner As a Room Divider As an Island* Right Side Corner Exterior Wall Chase 20’ MAX *Island installation with a top vent is possible as long as the horizontal portion of the vent system does not 20’...
  • Page 20: Nailing Tab Guide

    MQVL48 Single Side -Nailing Tab Guide- [Qty] 4 Nailing Tabs are located on each side of the front frame. NOTE: If using the rear nailing tabs for cantilevered chase etc., refer to the Nailing Tab page for MQVLB48 Bay Peninsula. Flat (As Shipped) Pull up 90°...
  • Page 21: Single Side Framing

    MQVL48 Single Side Framing TOP VIEW Stud Stud BACK WALL FRAMING 18-7/8” Framing Flush with Face FRAMING OVER FRONT TOP OF FIREPLACE FRAMING FRONT FIREPLACE FRAMING IN FRONT OF FIREPLACE Variable EXTENDED FRAMING FRONT FIREPLACE EXTENDED FRAMING IN FRONT OF FIREPLACE Appliance must be in place with venting connected before area above fireplace is framed in.
  • Page 22: Using Tile Lip

    MQVL48 Single Side - Using Tile Lip A Tile Lip is supplied for attachment above the fireplace opening. This can be used as a standard tile edging or as a mount bracket for other surfaces like drywall or plywood. Set to desired height and attach through holes in face of fireplace.
  • Page 23: Mqvl48S1Bl / Mqvl48S1Ss -Surround Installation For Mqvl48

    MQVL48S1BL / MQVL48S1SS -Surround Installation for MQVL48 -Option Surround is available in Painted Black or Stainless Steel. ASSEMBLY: PARTS LIST: - Attach Side Fillers to - Surround Frame Surround Frame with - [Qty 2] Side Fillers [Qty] 16 screws. - [Qty 20] #6 Screws NOTE: DO NOT OVERTIGHTEN...
  • Page 24: Vl48Sep Side Extension Panels

    MQVL48 Single Side- VL48SEP Side Extension Panels -Option- Contents if Kit: Qty 2 – Side Extension Panels Qty 4 - #6 Black Screws 4” 18-3/16” 19-7/16” Framing Details: FROM EDGE OF FIREPLACE TO OUTSIDE OF 2 X 4 HORIZONTAL FRAMING ABOVE TOP OF 19-3/16”...
  • Page 25: Locating Your Appliance

    MQVLB48 Bay Peninsula Locating Your Appliance LOCATION KEY: A. Corner Kit- Left Side B. Flat on Wall C. Corner Kit- Right Side D. Corner Kit- Left Side E. Corner Kit- Right Side F. 45° Corner G. As an Island* *Island installation with a top 20’...
  • Page 26: Peninsula Bay Framing

    MQVLB48 Peninsula Bay -Framing OPTION A: Framing Attached to Side of Fireplace- For building out around the fireplace. Framing must be self- supporting. SIDE VIEW -TOP VIEW- BACK WALL FRAMING ON TOP OF FIREPLACE EXTENDED FRAMING IN FRONT OF FIREPLACE 18-7/8”...
  • Page 27: Peninsula Bay Nailing Tabs And Framing

    MQVLB48 Peninsula –Nailing Tabs and Framing OPTION A: Framing Attached to Side of Fireplace- For building out around the fireplace. Framing must be self- supporting. SIDE NAILING TAB Optional framing attached to side MIN. 151 of fireplace SQ. IN. ⚠ DO NOT COVER TOP OF PLATFORM WITH A SHEET OF PLYWOOD.
  • Page 28 VLBCK48 Corner Kit for VLB48 Peninsula Bay Option MUST BE INSTALLED BEFORE UNIT IS INSTALLED INTO FRAMING. CORNER KIT CAN BE INSTALLED AT EITHER END OF FIREPLACE. ⚠ Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 29: Vlbck48 Corner Kit

    Place Heat Shield into outside fireplace opening. Fasten with [Qty 13] 1/2” DT Hex Heat Shield Screws. Set Stand- off into position. Install Inner Liner Firebox Panel inside firebox Cover and secure with [Qty 3] DT Screws Install Front Side Cover when installing Glass Lower Front...
  • Page 30: Using Tile Lip

    MQVLB48 Bay Peninsula - Using Tile Lip Drywall Drywall 84 Square Inches Free Air Minimum MQVLB48 Bay Peninsula -Facing Requirements Unit may be covered with combustible material (i.e. drywall) up to the fireplace opening. Option A: Open Chase at Ceiling Minimum 151 Sq.
  • Page 31: Glass Door Front Removal / Installation

    MQVL48 / MQVLB48 Glass Door Front Removal / Installation To remove Glass Door Front: Side Cover 1. Use a 3/8” wrench or socket to Panel Corner Cover remove the Side Cover Panels from a VL48 Single Side or the Corner Kit side of MQVLB48. Also, use a 3/8”...
  • Page 32: Door And Glass Information

    Door and Glass Information MQVL48 / MQVLB48 Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass.
  • Page 33: Glass Safety Barrier Installation / Removal

    MQVL48 / MQVLB48– Glass Safety Barrier Installation / Removal INSTALL SIDE GLASS FIRST. DECAL ON GLASS SHOULD FACE OUTSIDE. 16-3/16” 16-3/16” 54-5/8” 14-3/8” FRONT GLASS PANEL [QTY 1] SIDE GLASS PANELS [QTY 2] GLASS SUPPORTS INSERT GLASS INTO CLIPS PLACE GLASS INTO GLASS SUPPORTS.
  • Page 34: Safety Screen Installation / Removal

    MQVL48 – MQVLB48 Safety Screen Installation / Removal NOTE: For MQVLB48 Bay Peninsula, procedure is the same as shown for the front screen below. Sides should be installed or removed first. Screen goes here. Bend Top Tab Down 90° for Screens. Access Cover goes here Lower Front Panel Assembly...
  • Page 35: Component Locations

    MQVL48 / MQVLB48 Component Locations TOP VIEW GAS LINE 120 VAC LIGHT LIGHT 120 VAC VALVE DRIVER OPTIONAL MODULE BATTERY TRANSFORMER REMOTE PAIRING BUTTON (LED) BACKUP (HALOGEN) (SW1 SWITCH) REMOTE PAIRING BUTTON (SW1 SWITCH) DCHS Cover for Optional Remote Receiver- Millivolt or Proflame 1 Systems Only PROFLAME 1 C/W REMOTE...
  • Page 36: Halogen Lamps

    MQVL48 / MQVLB48 ULK4 Universal Light Kit Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Inside Firebox Bottom of Firebox Connect Switch Here ULK TRANSFORMER CONNECTIONS Connect switch wires between lamp wire and transformer. Connect remaining lamp wire to transformer. Plug transformer into powered receptacle or into Fan Control Module if used.
  • Page 37: Led Lighting

    LED Lighting MQVL48 / MQVLB48 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. NOTE: If appliance is directly connected to an electrical supply, it must be anchored using anchor points provided in bottom of appliance.
  • Page 38: Mqvl48Plb / Mqvl48Ple Porcelain Liner Installation

    MQVL48PLB / MQVL48PLE Porcelain Liner Installation Option -MQVL48PLB- BACK PANEL KIT NOTE: If using VLBCK48 CORNER KIT, remove Inner BACK FILLER Liner Panel from Corner Kit if installed. STEP ONE: Remove Liner Clips from inside of firebox with a 1/4” hex BACK LINER driver.
  • Page 39: Mqvl48Rgb / Mqvl48Gle Glass Liner Installation

    MQVL48RGB / MQVL48GLE Glass Liner Installation Option NOTE: If using VLBCK48 CORNER KIT and you are NOT -MQVL48RGB - BACK PANEL KIT installing a Glass End Panel, install Inner Liner Panel from Corner Kit before Glass Back Liner. However, if you ARE installing a Glass End Panel, do not install Inner Liner Panel 46-9/16”...
  • Page 40 INSTALLING MQVL48GLE: STEP FIVE: Reinsert screws halfway into holes where End Clips were. STEP SIX: Engage Front Slot of Tab onto Screw and slide bottom of End Panel into place. Tighten Screw and repeat for other side. There is no bottom attachment Screw.
  • Page 41: Mqvl48Rlb / Mqvl48Rle Liner Installation

    MQVL48RLFB / MQVL48RLFE Fluted Liner Installation Option -MQVL48RLFB- BACK LINER KIT NOTE: If using VLBCK48 CORNER KIT, remove Inner Liner Panel from Corner Kit if installed. STEP ONE: BACK LINER BACK LINER Remove Liner Clips from inside of firebox with a 1/4” hex driver. -MQVL48RLFE- END LINER KIT LEFT RIGHT...
  • Page 42: Mq Dealer Accessories For Vl48 / Vlb48 Mq Glass

    MQVL48 / MQVLB48 MQ Dealer Accessories The following Accessories are available through MQ Dealers only. GLASS (MQG5W, MQG5C, MQG5A, MQG5B) ACCESSORY ITEM DESCRIPTION  If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass embers do not excessively MQG5W Decorative Glass 1/2”...
  • Page 43: Mqrock2, Mqrock3, Mqrbd1

    MQROCK2, MQROCK3, MQRBD1 - Place rocks randomly onto False Bottom.  MQRock2 MQRock3 MQRBD1 NOTE  Pilot Area Must Not Be Covered, as delayed ignition can occur.  Do Not Cover any part of the burner tube with logs as sooting may occur. ...
  • Page 44: Mqrbd3 5 Piece Driftwood Log Set

    MQRBD3 -5 Piece Driftwood Log Set- Can be used with MQ Glass, MQ Rock, MQ Stone or MQ Ember. Follow instructions for these accessories. ⚠ NOTE LOG 1  For best flame pattern it LOG 3 is essential to spread supplied Crushed Glass or MQEMBER directly LOG 4...
  • Page 45: Gas Line Installation / Gas Specifications Chart

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 46: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When ...
  • Page 47: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not light. Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is electrode at pilot.
  • Page 48: Burner System Maintenance

    Burner System Maintenance MQVL48 / MQVLB48 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. ⚠ -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 49: Gas Conversion Part A

    Gas Conversion Part A MQVL48 / MQVLB48 Models: MQVL48LP, MQVL48N, MQVL48LPE, MQVL48NE, VL48N, VL48LP, VL48NE, VL48LPE, MQVLB48LP, MQVLB48N, MQVLB48LPE, MQVLB48NE, VLB48N, VLB48LP, VLB48NE, VLB48LPE Kit Number Description Pilot Orifice Burner Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) 48VL-CKLP...
  • Page 50: Gas Conversion For Top Convertible Pilot - Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 51: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 52: Burner Tube Removal

    MQVL48 / MQVLB48 Burner Tube Removal Pilot Shield False Bottom Burner Tube Burner Tube Mount Bracket 1. Remove Pilot Shield [Qty 2 DT Screws] and False Bottom [Qty 8 DT Screws]. 2. Remove the [Qty 8] DT Screws from the lower portion of the Burner Tube Mount Brackets. 3.
  • Page 53: Proflame 1 Ipi Electronic Ignition System

    Proflame 1 -IPI Electronic Ignition System- Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an Remote Receiver intermittent igniting system. This alternating Module mode is controlled by the CPI/IPI Switch (Optional) (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
  • Page 54: Remote Control Operation

    Proflame 1 -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 55: Configuration #1: Basic Manual Hi/Lo And Manual On/Off Capabilities

    Proflame 1- Configuration #1: Basic Manual HI/LO and Manual ON/OFF Capabilities Proflame 1 Parts List- Standard System ITEM PART NO. DESCRIPTION SCHEMATIC 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si...
  • Page 56: Configuration #2: Remote On/Off And Manual Hi/Lo Capabilities

    Proflame 1- Configuration #2: Remote ON/OFF and Manual HI/LO Capabilities OPTIONAL: For units with remote HI/LO capabilities, a modulating servo is required to be installed on the valve. The connectors to this servo must be connected to the Remote Harness as shown. SCHEMATIC PICTURE NOTE: Fan Option...
  • Page 57: Configuration #3: Remote On/Off, Variable Hi/Lo, And Fan Capabilities

    Proflame 1- Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities Refer to the fan installation/removal section for fan installation. NOTE: This Configuration is not available on all models of SCHEMATIC fireplace. Check with your dealer. NOTE: Fan Option PICTURE is not available on some models of fireplace.
  • Page 58: Operating The Receiver Without Batteries- Millivolt And Proflame 1

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 59: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 60: Proflame 1 Ipi Electronic Ignition System Proflame 2 Parts List / Basic System / Configuration Gtmfl

    Proflame 2- Parts List- Basic System, Parts List, Configuration GTMFL ITEM PART DESCRIPTION NUMBER 1005-P001si IPI Valve NG with Stepper Motor 885.001 1005-P002si IPI Valve LP with Stepper Motor 885.001 1006-P002si IPI Valve NG Hi / Lo 1006-P003si IPI Valve LP Hi / Lo 1002-P033si Pilot NG IPI 199.059 1005-P325si...
  • Page 61: Proflame 2 Module And Remote Control

    Proflame 2 Module and Remote Control PRESS BUTTON REMOTE PAIRING BUTTON (SW1 Switch) Pairing Remote Control Press the SW1 button until you hear three beeps.   Install the 3 AAA batteries in the battery bay, located on the  Within 10 seconds press the button again until you base of the Remote Control.
  • Page 63: Vent Termination

    Vent Termination WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN Notes: REQUIRED BY LOCAL 1) Clearances are to the edge of the terminal plate. CODES. Add 6-3/4” to clearances to arrive at centerline. 2) Local codes or regulations may require different clearances.
  • Page 64: General Vent Installation

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with 5 x 8 M&G-Duravent Direct...
  • Page 65: Venting Routes And Components

    Venting Routes And Components Venting Routes and Components Since it is very important that the vent system maintain its How to Use the Horizontal Vent Table balance between the combustion air intake and the flue gas 1. Determine the height of the system and the number of exhaust, certain limitations as to vent configurations apply and bends required.
  • Page 66: Venting Straight Up Through Roof

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 67 -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z58VT 18” 43ft Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting...
  • Page 68: Approved For Power Vent Pvh58

    Approved for Power Vent PVH58 - This appliance is approved for use with the Kingsman PVH58 Horizontal Power Vent - The PVH58 Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 69: Pvh58 Parts List

    PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQVL48 / MQVLB48 VENTING AND VENTING ADAPTERS -For fireplaces to be converted to hard pipe (M&G-Duravent-DirectVent Pro, etc.) at the fireplace: Z58DFA M&G-Duravent Fireplace Adapter -For Power Vent installations where flex pipe will be used up to the Power Vent unit: Z58PVA Flex Connector Set- ZDV5FC (5”...
  • Page 70: Fireplace Models

    MQVL48 / MQVL48B Fireplace Models MARQUIS FIREPLACES Single Side Fireplaces Peninsula Bay Fireplaces MQVL48N (Millivolt) Fireplace Heater rated, NG, MQVLB48N Peninsula Bay Fireplace (Millivolt), Heater Ceramic Glass, Low E Tempered Glass rated, NG, Ceramic Glass, Low E Tempered Safety Barrier, Lights...
  • Page 71: Mqvl48 / Mqvl48B Parts List

    Frame Grill Mount (Black) System (MQVL48LP) VL48HDS Heat Distribution System- (Flex Pipe Not 48VL-BNGSI Burner Assembly- Natural Gas c/w Valve Included) System (MQVL48N) ZDV5FP6 Flex Pipe 5” Diameter x 6FT – (4 per Kit) 48VL-BLPSIE Burner Assembly- Propane c/w Valve System (MQVL48LPE) VL48AVP Adjustable Vented Platform- Mounting Base for fireplace- Adjusts from 14-3/4”...
  • Page 72: Warranty

    Transformer MET60-1 GTMRCN Remote Control Millivolt – P601 Thermostat/Modulating - NG GTMRCP Remote Control Millivolt – Thermostat/Modulating - LP Kingsman Fireplace Venting GTFRCN Remote Control Millivolt – Z58DFA M&G-Duravent Adapter (5 x 8) Thermostat/Modulating/Fan - NG Vertical Vent Termination Z58VT GTFRCP Remote Control Millivolt –...
  • Page 73: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

Table of Contents