The heat pump is giving off water: is this normal?
Your appliance will give off water in the form of condensation. This water is
the humidity contained in the air which condenses on contact with certain
cold components inside the heat pump.
Caution: your appliance can drain several litres of water per day.
Where should my water treatment system be positioned
with respect to the heating system?
The water treatment system (chlorinator, salt chlorinator, etc...) must be
installed preferably downstream from the heat pump (see installation
§1.3.3), and must be compatible with the latter (check with the manufac-
turer).
6

Technical information

Before working on the appliance, ensure that it is disconnected from the
power supply.
Do not vent R410A into the atmosphere: R410A is a fl uorinated greenhouse
gas, covered by the Kyoto Protocol, with a Global Warming Potential (GWP)
= 1975 - (Directive of the EC 842/2006).
Removing or shunting any of the appliance's safety elements will automati-
cally void the warranty. Use only original manufacturer parts when replac-
ing faulty or worn parts.
6.1 Technical specifi cations
Single phase voltage
Power consumption*
Power restored*
Nominal current consumption*
Average water fl ow-rate
Maximum water fl ow-rate
Protection calibre
*with an ambient air of +15 °C and a pool water of 24 °C, humidity 70%
• unit protection class: IP 24
• refrigerant gas: R410A
• refrigerant charge: see product information plate
12
PW
COP*
5M
230V-50 Hz
kW
0.98
kW
4.65
A
4.45
4.7
3
m
/h
3
3
m
/h
A
7M
9M
1.56
2.06
6.52
8.6
7.09
9.36
4.2
4.2
4
5
8
16