I Technical Specifications - Zodiac PX50 MD12 Instructions For Installation And Use Manual

Table of Contents

Advertisement

5.2 I Technical specifications

PX50
Operating
temperatures
Power output (max-
min speed)*
Voltage
Admissible variation in voltage
Pollution class**
Pollution degree**
Overvoltage category**
Nominal current
input
Maximum electric
current requirement
Minimum cable
size**
Max Discharge/
Suction pressure
Max High pressure/
Low pressure side
Average water flow
rate
Sound pressure at
10 m
Refrigerant type
Refrigerant load
CO
equivalent
2
Approximate weight
Appliance must have a protection rating (IP) IPX4 or above. Please read the label showing the protection rating IP for
your product.
* Performance levels: air at 28 °C/water at 28 °C/humidity at 80%.
** These specifications have been determined based on the requirements defined in standards IEC/EN 60335-1 and IEC/EN 60035-2-40 on the safety
of electrical appliances for household and similar purposes.
*** Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC 15-100), must be checked and adapted to
the installation conditions and standards of the installation country.
30
MD3
MD4
MD5
air
Heating: from -12°C to 43°C/Cooling: from 15°C to 43°C
water
10.5 -
13.5 -
kW
9 - 1.9
2.1
A
4.6
5.9
A
6.34
7.63
9.18
mm²
3 x 1.5
3G1.5
bar
bar
m³/h
2.9
3.4
db(A)
31
32
kg
0.72
0.55
T
0.49
0.37
0.54
kg
52
58
MD6
MD7
MD9
Heating: from 6°C to 41°C/Cooling: from 6°C to 35°C
16.5 -
19.5 -
25 - 4.5
2.5
5.3
3.5
220V-240V/1/50Hz
± 10 %
I
2
II
7.2
9.2
10.5
13.2
10.78
13.33
16.59
3 x 2.5
3G2.5
45
25
4
4.8
6
7.4
33
35
R32
0.8
0.81
1.5
1.7
0.55
1.01
1.15
61
62
89
92
MD11
TD11
MD12
31 - 5.6
35 - 7.6
380V-415V
220V-240V
/3/50 Hz
/3/50Hz
17
7
23.16
18.9
8.2
23.16
3 x 4
5 x 2.5
3 x 6
3G4
5G2.5
3G6
9.8
8
10.3
39
50
R410A
R32
2.4
3
2.4
1.62
6.26
1.62
120
123
126
TD12
380V-415V
/3/50 Hz
8.4
8.4
5 x 4
5G4
10
68
R410A
4
8.35
128

Advertisement