OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
The minimum distance between light-output and the illuminated surface must be more than 1.5 meter.
The maximum ambient temperature t
The relative humidity must not exceed 50 % with an ambient temperature of 45° C.
If this device is operated in any other way, than the one described in this manual, the product may suffer
damages and the warranty becomes void.
Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash
etc.
You endanger your own safety and the safety of others!
Improper installation can cause serious damage to people and property !

Rigging

Please follow the European and national guidelines concerning rigging, trussing and all other
safety issues.
Do not attempt the installation yourself !
Always let the installation be carried out by an authorized dealer !
Procedure:
If the Spectral CYC2000 is lowered from the ceiling or high joists, professional trussing systems have
to be used.
Use a clamp to mount the Spectral CYC2000, with the mounting-bracket, to the trussing system.
The Spectral CYC2000 must never be fixed swinging freely in the room.
The installation must always be secured with a safety attachment, e.g. an appropriate safety net
or safety-cable.
When rigging, derigging or servicing the Spectral CYC2000, always make sure, that the area
below the installation place is blocked and staying in the area is forbidden.
The Spectral CYC2000 can be mounted in a hanging position (Fig. Above) or Upright (Fig. Below), using
the support brackets. Mounting the Spectral CYC2000 with a clamp or any other mounting bracket is
recommended, depending on the requirements of your application.
The Spectral CYC2000 can be placed on a flat stage floor or mounted to any kind of truss by a clamp.
Improper installation can cause serious damage to people and property !
= 45°C must never be exceeded.