Dmx Addressing With Id Address - SHOWTEC Spectral CYC2000 Product Manual

Showtec spectral cyc2000
Table of Contents

Advertisement

DMX512 ADDRESSING WITH ID ADDRESS (STAG MODE)
1) Connect a DMX controller (example 50720 Showdesigner 1024) to the series of Spectral CYC2000„s.
2) Each Spectral CYC2000„s has 15 DMX channels (DMX address LED Par #1=1, Par #2=16, Par #3=31,
Par #4=46, etc.).
3) Any DMX address in the range from 001 to 512 may be used.
4) Each DMX address may carry up to 66 separate ID addresses.
5) The ID Address should be set in the SETTINGS menu, on each unit in ascending values (i.e. 1,2,3...).
6) ID On should be set in the SETTINGS menu on each unit.
7) ID addresses are accessible from CH15 on the DMX512 controller.
Example 1
Showdesigner 1024 (50720)
The figure above shows a simple DMX layout. All the Spectral CYC2000„s have different ID addresses
which allows the user to collectively control the whole group of Spectral CYC2000„s with the same DMX
address by setting CH15 to 0, or to control each Spectral CYC2000 independently by first selecting the
DMX address and then by using CH15 to locate the target ID address.
Example 2
Showdesigner 1024 (50720)
The figure above shows a simple DMX layout. All 3 Spectral CYC2000„s have different ID addresses, which
allows the user to collectively control a group of 3 Spectral CYC2000„s with the same DMX address by
setting CH15 to 0, or to control each Spectral CYC2000 independently by first selecting the DMX address
and then by using CH15 to locate the target ID address.