6. View of the Hot Tank inside the machine.
7. At this stage, determine
which type of Hot Tank
is fitted.
8. Carefully disconnect the four silicone rubber pipes and the Thermistor Probe if applicable.
9. Remove the two screws holding the
Hot Tank and carefully ease the Tank
out of the machine as far as the
electrical connections allow.
10. Carefully disconnect the spade
terminals from the external
sensor(s) on the Hot Tank.
a) Internal Element Tank
(Discontinued-Can be
retrofitted all with
newer types.)
b) Thermister Probe Tank
(NB. External sensor
mountings may vary)
Top Bolt
628 & 698 Models
c) External Thermostat
Tank (Can also be
retrofitted to earlier
Models-for upgraded
Procedure , see
separate Technical
Guide)
Bottom Bolt
61