628 & 698 Models
Installing the Level Sensor
698/698H Models:
Fig.1
Fig.2
Fig.3
Fig.4
Fig.5
17
1. Ensure water and electricity supplies to machine are switched off.
2. Remove Tap Cover Panel and disconnect PCB
3. Remove Front Panel. (Be ready to catch Lower Door when lifting
Front Panel Clear)
4. Carefully remove screws from rear condenser panel and gently ease
panel away.
5. Fit short drainage tube to drainage outlet on rear on Front Panel (with
any curve running up in centre as shown in picture 1)
6. Refit Front Panel (and Lower Door) routing drainage tubing under Hot
Tank towards back of machine.
7. Fit Drainage Elbow fitting (see picture 2)
8. Position Elbow through hole in shelf (picture 3) and hold in position by
fitting second drainage tube from underside (see picture 4)
9. Position Drainage Tank in lower compartment
10. Fit Control Unit to inside wall of lower compartment with self-
adhesive pad as supplied
11. Connect small wiring to Float Switch assembly on tank
12. Disconnect main wiring terminal block (See picture 5) and insert
Control Unit wiring. (The terminals are individually configured to
ensure correct order of connection).
13. Carefully refit the rear condenser panel and turn on the inlet supplies
14. The Level Sensor is now ready for use. The Control unit will bleep
when the tank requires emptying after which it will automatically
reset.