Hot & cold switches
Inlet
Sanitisation & Cleaning
1. To commence sanitisation, simply isolate the water supoply and remove the filter cartridge.
2. Having removed the filter cartridge you now connect the dosing cartridge supplied by Azure with 125ml of
sanitisation fluid inside.
3. Now simply hold on the cold and ambient water button until the sanitisation until the sanitisation fluid hsa been
flushed through the system.
4. The last stage is to fully clean the external casing with Azure sanitisation wipes. When this has been completed
your sanitisation is complete.
If you have any question regarding sanitisation please do not hesitate to ring Azure Head Office on
0845 4 50 30 90.
11
Top cover
Cover of Header
Tank
Ice Bank
Header Tank
Float Valve
Indicator Panel
Cold Water Button
Hot Water Button