Settings (Continued)
■ Set-up Menu 2 (Set-up of Communication, Contact Input Reset Procedure)
In the operation mode, press
+
,
Set-up menu
DISPLAY SET
+
,
① Communication method
DISPLAY SET
+
,
② ModBus address
DISPLAY SET
+
,
③ ModBus baud rates
DISPLAY SET
+
,
④ ModBus parity
DISPLAY SET
+
,
⑤ ModBus stop bit
DISPLAY SET
+
,
⑥ CC-Link station number
DISPLAY SET
+
,
⑦
CC-Link baud rates
DISPLAY SET
+
,
⑧ Communication module reset
DISPLAY SET
+
,
⑨ Digital input reset
SET
+
,
Set-up menu
■ Set-up Menu 3 (Bar Graph Set-up)
In the operation mode, press
+
,
Set-up menu
DISPLAY SET
+
,
① Current maximum scale
DISPLAY SET
+
,
② Active power maximum scale
DISPLAY SET
+
,
③ Active power scale
DISPLAY SET
+
,
④ Reactive power maximum scale
DISPLAY SET
+
,
⑤ Power factor scale
SET
+
,
Set-up menu
1. Accuracy is defined to rated current. Although the maximum scale may display 120% or more of rated current and rated voltage in order to make
the scale easy to read, current input is within 100% of rated current.
Note
2. When the display pattern that does not display power, reactive power, active energy, and reactive energy is selected, the setting item related to
them is skipped.
8
and
simultaneously for 2 seconds or more, and the following operation becomes available.
SET
RESET
Set the set-up menu number to "2".
–
–
② Set the ModBus address number.
In case of CC-Link, this display does not appear.
–
Settable addresses: 1 to 255
–
④
Set the ModBus parity.
In case of CC-Link, this display does not appear.
–
Settable parity :
non
odd
EVEn
–
⑥
Set the CC-Link station number.
In case of ModBus, this display does not apper.
–
Settable addresses: 1 to 64
–
⑧
Reset of communication module.
In case of ModBus, this display does not apper.
–
Set it ON.
oFF
on
Note: When it is not set on ON, changed station
number and baud rate do not become valid.
–
According to the set-up diagram (page 6), save the
changed contents or continue to the other set-up menu.
–
and
simultaneously for 2 seconds or more, and the following operation becomes available.
SET
RESET
Set the set-up menu number to "3".
–
–
② Set the maximum scale of active power.
The maximum scale is set in the range of about 40%
–
to about 120% of the rated full load power.
Note: This insturument's rating is 100% value.
For the maximum scale value, please refer to
the user's manual.
–
④ Set the reactive power maximum scale.
–
②
The setting method is same as that of
power.
–
According to the set-up diagram (page 6), save the
changed contents or continue to the other set-up menu.
–
maximum scale value of active
①
Set the "CC-Link" or "ModBus" as the
communication method.
This display appears only if the type ME96NSR-MB
has the type ME-0040C-NS96 option module.
CC
:
CC-Link
:
485
ModBus
③
Set the ModBus baud rate.
In case of CC-Link, this display does not appear.
Settable baud rate:
2400 bps
4800 bps
9600 bps
19.2 kbps
38.4 kbps
⑤
Set the ModBus stop bit.
In case of CC-Link, this display does not appear.
Stop bit : 1
Stop bit : 2
⑦ Set the CC-Link baud rates.
In case of ModBus, this display does not apper.
Settable baud rates:
0 : 156k
1 : 625k
2 : 2.5M
3 : 5M
4 : 10M
⑨
Set the digital input(DI) reset method.
Without digital input, this display does not apper.
Auto: Automatic method
HoLd: Manual method
Note: When selected the manual method(HoLd), input state is kept until the
cancel operation is done manually. For the method of the cancel operation,
refer to page 21.
① Set the current maximum scale.
The maximum scale is set in the range of about 40%
to about 120% of the rated current.
Note: This insturument's rating is 100% value.
For the maximum scale value, please refer to
the user's manual.
③ Set the single / double deflection of active power.
When + and – are pressed, the scale value of
bar graph flickers at single / double deflection.
⑤ Set the power factor scale.
0.5
0